2-4-3

¡Supera tus tareas y exámenes ahora con Quizwiz!

In a self-contained meter, the entire current passes through the ? . a.disk b.meter c.secondary coil d.voltage coil

B. Meter

A residential meter is rated for a certain ? of expected load. a.average span b.peak c.range d.voltage

C. Range

A meter that measures demand and is independent of the kWH assembly is a ? meter. a.demand b.mechanical c.primary d.thermal

D. Thermal

A mechanical demand meter is controlled by the accuracy of the basic watt-hour meter. Select one: True False

True

Dropping or picking up a load at 480/277 is dangerous because of very high available fault current at these voltages. Select one: True False

True

Time-of-use customers are beneficial to the electrical provider because they use generation that would otherwise be underutilized. Select one: True False

True

A minimum of ? voltage checks should be made prior to setting a residential meter. a.5 b.6 c.7 d.8

d.8

The meters most commonly used for demand metering are ? and ? . a.kW / kVA b.mechanical / electronic c.thermal / electronic d.thermal / mechanical

d.thermal / mechanical

A self-contained meter has no limits as to the type of service it can be used on. Select one: True False

False

It is acceptable to install a 480-volt meter in a live base as long as voltage checks are made. Select one: True False

False

Voltage checks are not required if the customer's main breaker on a residence is opened. Select one: True False

False

The general rule of thumb for meter elements is to have ? fewer element(s) than the number of wires in the service to be measured. a.1 b.2 c.3 d.4

a.1

The two main types of meter construction are electromechanical and ? . a.electronic b.Kh constant c.self-contained d.transformer rated

a.electronic

A transformer rated meter normally reduces the voltage and current to ? and ? for metering purposes. a.10 V / 5 A b.120 V / 5 A c.240 V / 10 A d.277 V / 10 A

b.120 V / 5 A

The aluminum meter disk of a single-phase meter disk turns because of ? . a.a gear train b.eddy currents c.magnetic flux d.the permanent magnet

b.eddy currents

A meter that is connected by a set of gears to the register is the ? meter. a.average demand b.electromechanical c.electronic d.peak demand

b.electromechanical

The type of meter that can check the voltage and current in each phase is a(n) ? meter. a.electromagnetic b.electronic c.poly-phase d.single-phase

b.electronic

A customer with a(n) ? power agreement has to cut back his or her power demand when asked to do so. a.demand b.interruptible c.large d.small

b.interruptible

The Kh constant of a meter relates to the ? of ? to the load being registered. a.current / service wires b.number / disk rotations c.number / meter coils d.voltage / the secondary

b.number / disk rotations

Primary metering uses ? and ? to meter a customer. a.CTs / current transformers b.CTs / MTs c.CTs / PTs d.PTs / meter coils

c.CTs / PTs

On a 120/240-volt service being served by a self-contained meter, the voltage coil of the meter is connected from ? . a.L1 to L2 b.S1 to N c.S1 to S2 d.S2 to N

c.S1 to S2

Real power is measured in ? . a.kVA b.kVAR c.kW d.kWHA

c.kW

Power factor is the ratio between ? and ? . a.kVAR peak / kVA peak b.kW peak / kVA c.kW peak / kVA peak d.kW peak / kVAR peak

c.kW peak / kVA peak

There are three kinds of electrical power: real, apparent, and ? . a.average b.peak c.reactive d.resistive

c.reactive

The Kr constant of a meter regulates the ? . a.current flow through the meter b.speed of the disk c.speed of the register d.voltage flow through the meter

c.speed of the register


Conjuntos de estudio relacionados

Econ 1, Module 28, 34: Monopoly, Monopolistic Competition

View Set

AS Level ICT: Hardware and Software

View Set

Fundamentals Exam 1 set 5 infection control, prevention, and management

View Set

Fitzgerald Practice Questions Endocrine

View Set

Quizzes Statistical Quality Management

View Set

פסחים פרק ב משנה ו

View Set