73%

By stringing a fourth wire and reconnecting the substation transformer secondaries from delta to wye, the capacity of the circuit can be increased by ? .

False

In a delta connected 3-phase system, the line current is equal to the phase current.

Only one voltage is available between any two wires

In a delta system, ? .

1.73

In a delta system, the line current is equal to ? times the phase current.

False

In a wye connected system, the amount of voltage from the tip to the center of the Y (across a single winding) is known as the line voltage.

1.73

In a wye connected system, the line voltage is equal to ? times the phase voltage.

Line

In a wye connected system, the voltage from tip to tip (between the lines) is known as the ? voltage.

58%

The current flow in a wye circuit is about ? less than in an equivalent delta circuit.

3 wire

The delta system is also called a ? system.

Y

The two basic types of 3-phase distribution systems are symbolized by a delta symbol (Δ) and a(n) ? .

12470 Y

When a 3-phase, 3-wire, 7,200-volt delta circuit is cut over to a 3-phase, 4-wire wye circuit, the line voltage is ? .

Phase

In a delta system, the line voltage and the ? voltage are the same.

True

In a delta system, the three phases are connected in series.

True

The most commonly used 3-phase distribution system is the wye system.

7,200/12,470Y V

The most popular distribution voltage in use today is the ? system.

Wye

When a 3-phase transformer bank is connected in a ? configuration, one end of each coil is connected together at a common point.

200 amps

If the line current in a wye system is 200 amperes, the phase current is ? .

2400 wye

If the line voltage in a delta system is 2,400 volts, the phase voltage is ? .

346 A

If the phase current in a delta system is 200 amperes, the line current is ? .

120 V

If the phase-to-phase voltage in a wye system is 208 volts, the phase-to-neutral voltage is ? .

Phase

The voltage measured across a single winding or phase is known as the ? voltage.

120 degrees

The voltages of a 3-phase system are ? out-of-phase with each other.

4 wire

The wye system is also called a ? system.

False

There are three different voltages available in a wye connected system.


Conjuntos de estudio relacionados

ECO2013-Andrew Tucker-Exam Three

View Set

Scientific management and Taylorism

View Set

Fahrenheit 451 Quote Identification

View Set

4.3.5Quiz: The Globalization of Culture World Geography Studies Sem 2

View Set

W01 PM Vocabulary, CIT 380 Unit 2 Test, CIT 380 Unit 3 Test, CIT 380 Unit 1 Test, PMI Lexicon of Project Management Terms

View Set

HBS 3.2.2 Pancreas, liver and gall bladder

View Set

Signs, Pavement Markings, and Signals

View Set

coral reef ecology final OCE4265

View Set

Unit 2: Tableau Desktop Specialist Exam

View Set