chapter 40

¡Supera tus tareas y exámenes ahora con Quizwiz!

Which of the following must be disclosed to the patient before obtaining informed consent for dental radiographs

Risks and benefits of the images, Person who will be exposing, Consequences of not having images

Transporting PSP films should be done by placing them in

a black transfer box

All the following are true statements regarding the preparation of the operatory for dental imaging except

barriers do not need to be used because spatter of blood and saliva is unlikely

Following the completion of the film-screen contact test, areas of good film-screen contact will

be uniform

According to the test for X-ray film freshness, the film is fresh and has been properly stored and handled when the processed film appears clean with a slight _______ tint

blue

Once films are removed from the mouth, they are considered contaminated and should be

handled only with gloved hands

the simplest method for ensuring the freshness of each box of film is to

process one film from each box with fresh chemicals

The safelight in the darkroom can be tested by ____________.

using the coin test

Following removal of an exposed film or PSP from a patient's mouth, the film/PSP should be

wiped free of saliva using a dry 2 x 2-inch gauze sponge or paper towel.

The most critical component in film processing quality control is

maintaining the freshness of the processing solutions

A record-keeping log for processing solution does not need to include the

name of the solution used to clean the tanks.

Failure to obtain informed consent from a patient prior to exposure of dental radiographs can lead to charges of

negligence

Dental records must contain documentation of the _____ of dental images taken

number, type, Quality

An administrative quality control plan

All of the above are correct

Dental images are the property of the

dentist

All the following are true regarding the transfer of dental images except

the originals are sent

Who can be held legally responsible for a dental assistant's actions?

Both the dentist and assistant

Who is responsible for overall quality assurance in a dental practice?

Dentist

What should the dental assistant do if a patient refuses dental imaging?

Document in the patient's record the fact that he or she refused recommended dental imaging.

Which of the following statements is true regarding federal and state regulations on the use of dental X-ray equipment?

Most states have laws that require inspections of dental x-ray equipment on a regular basis

Calibration of dental x-ray equipment should be performed by

a qualified technician

Developer strength can be checked by using

a thermometer

Sterilized positioning instruments should be removed from the packages

after the patient is seated.

All the following statements are true regarding the care of intensifying screens except

all of the above are correct

PSPs

are a major source of cross-contamination

It is the responsibility of the to discuss the need for dental imaging

dentist

Given normal use, processing solutions should be changed

every 3 to 4 weeks

The Consumer-Patient Radiation Health and Safety Act is a federal law that requires all

persons who expose dental x-rays to wear radiation safety badges

According to the Centers for Disease Control (CDC) Guidelines for Infection Control in Dental Healthcare Settings—2003, digital radiography sensors

should use FDA-cleared barriers

Quality assurance in the dental office is a way of ensuring that everything possible is being done to produce high-quality diagnostic images and includes quality control

tests and administration procedures

Regulations regarding certification for dental assistants in radiography

vary from state to state

When a daily radiograph is lighter than the reference radiograph, it indicates the developer is too

weak

For a film to be properly processed, it should be left in a fixer solution, at full strength, for

2 minutes

A good protocol to follow for decreasing the contamination of dental imaging equipment and supplies is to

All of the above are correct

Quality control for the darkroom should include

Checking for light leaks every 6 months, safelight testing, equipment testing


Conjuntos de estudio relacionados

agency relationships multiple choice

View Set

Personal Finance LU3 (Chapters 4 and 5)

View Set

BAS 282: Public Relations: SmartBook

View Set

Short Sale Course California Real Estate

View Set

5.4- solve higher-order polynomials equations and inequalities in one and two variables

View Set

Chapter 12 Terms and Quiz: Shock

View Set