ICD-10-PCS
A diagnostic irrigation of the nose using an irrigating substance via a percutaneous approach is reported with code _____.
3E1938X
A diagnostic irrigation of the nose using irrigating substance via a percutaneous approach is reported with code ________.
3E1938X
In Table 5A1, a duration of 28 hours would be reported with a value of _____.
4
In Table 5A19, durations of 28 hours would be reported with a value of ________.
4
Measurement and monitoring procedures are reported with a section value of _____
4
Measurement and monitoring procedures are reported with a section value of _________
4
The measurement of peripheral arterial sound using an open approach would be reported with code _____.
4A030H1
The measurement of peripheral arterial sound using an open approach would be reported with code ________.
4A030H1
Which code is used to report an open pulmonary venous pressure measurement?
4A040B3
Which of the following would report the measuring of lymphatic pressure using an open approach?
4A060BZ
Which of the following would report the measuring of lymphatic pressure, using an open approach?
4A060BZ
The monitoring of coronary arterial pressure using a percutaneous approach would be reported with code _____.
4A133BC
The monitoring of coronary arterial pressure using a percutaneous approach would be reported with code ________.
4A133BC
Which of the following codes would report monitoring of peripheral arterial saturation, external approach?
4A13XR1
In Table B82 the body part of left eye is reported using a value of ________.
6
In Table B82, the body part of left eye is reported using a value of_____.
6
In table B82 the body part of left eye is reported using a value of
6
In table B82 the body part of the left eye is reported using a value of
6
Which code is used to report indirect osteopathic treatment of a pelvis
7W05X4Z
Which code is used to report indirect osteopathic treatment of the pelvis?
7W05X4Z
Therapeutic massage performed on musculoskeletal system would be reported with code
8E0KX1Z
Therapeutic massage performed on musculoskeletal system would be reported with code ________.
8E0KX1Z
Therapeutic massage would be reported with code
8E0KX1Z
Therapeutic massage would be reported with code _____.
8E0KX1Z
Non-manual chiropractic manipulation of the lumbar area is reported with code
9WB3XBZ
Non-manual chiropractic manipulation of the lumbar area is reported with code ________.
9WB3XBZ
Nonmanual chiropractic manipulation of the lumbar area is reported with code
9WB3XBZ
Nonmanual chiropractic manipulation of the lumbar area is reported with code _____.
9WB3XBZ
An MRI of the bilateral renal veins would be reported with code
B53LYZZ
An MRI of the bilateral renal veins would be reported with code ________.
B53LZZZ
An MRI of the bilateral renal veins would be reported with code_____.
B53LZZZ
In Table DF0 the value of 0 denotes ________.
Beam radiation
In Table DF0, the 0 denotes _____.
Beam radiation
In table DF0 the 0 denotes
Beam radiation
In the table DF0 the value of 0 denotes
Beam radiation
The fourth character of the Medical and Surgical section of ICD-10-PCs represents the _____.
Body part
The fourth character of the Medical and Surgical section of ICD-10-PCs represents the _________
Body part
Nuclear Medicine procedures are reported with a section identifier of _________.
C
The section identifier for Nuclear Medicine is_____.
C
The section identifier for nuclear medicine is____
C
A PET scan of the myocardium using 0-15 would be reported with code
C23GMZZ
A PET scan of the myocardium using O-15 would be reported with code
C23GMZZ
A PET scan of the myocardium using O-15 would be reported with code _____.
C23GMZZ
A PET scan of the myocardium using O-15 would be reported with code: ________.
C23GMZZ
In code 9WB6XFZ the F denotes
Direct visceral
In code 9WB6XFZ, the F denotes _____.
Direct visceral
In the code 9WB6XFZ the F denotes
Direct visceral
In the code 9WB6XFZ, the F denotes ________.
Direct visceral
In Table 3E0 the character 4 value that represents products of conception is ________.
E
In Table 3E0, the character 4 value that represents products of conception is _____.
E
In Table 10Y the qualifier of P represents the _____
Endocrine system
In Table 10Y the qualifier of P represents the ________.
Endocrine system
A third character of D in the Obstetrics Section represents _____.
Extraction
A third character of D in the Obstetrics Section represents ________.
Extraction
To code a forceps delivery, the coder should reference the term _____ in the index.
Extraction or delivery
A CT scan of the thoracic aorta using high osmolar contrast would be reported using code B2300ZZ
False
Amniocentesis is a procedure in which an open incision is made into the uterus to withdraw fluid for examination
False
Decompression, in the Extracorporeal or Systemic Therapies section, is defined as taking over a portion of a physiological function by extracorporeal means.
False
Extraction is defined in the Obstetric Section as artificially terminating a pregnancy.
False
For the code 10D07Z3, the 3 represents internal version.
False
For the fourth character of the Obstetrics Section, a value of 1 means products of conception, ectopic.
False
Imaging is reported with section identifier 9.
False
Imaging procedures include plain radiology, flouroscopy, CT, MRI, and ultrasound
False
In ICD-10-PCS packing is defined as "putting material on a body region for protection."
False
In Obstetrics Table 109, the only qualifier is Z
False
In Table 302, the 2 represents irrigation
False
In code 2W25X4Z, the 5 represents the body region of the abdominal wall
False
In table 8E0, in vitro fertilization has a qualifier value of 6
False
In table B00 character 5 denotes the body part imaged
False
In table B23, the 3 denotes plain radiography
False
In the code 3E060HZ, the H represents a destructive agent.
False
In the code 3E0T3GC, the T represents bone marrow
False
Irrigation is defined in ICD-10-PCS as the putting in of blood or blood products
False
It is possible to construct a procedure code from the alphabetic index.
False
Osteopathic procedures have a first character value of 8
False
Substance abuse treatment and mental health services are reported from the same section of ICD-10-PCS.
False
The approach for injections is open.
False
The root operation of bypass is defined as the modifying of an anatomical structure of a body part without affecting the function of the body part.
False
The root operation of dressing has a third character value of 1.
False
The root operation of fusion is defined as the breaking up of solid matter in a body part into pieces.
False
The second character in the Medical and Surgical section of ICD-10-PCS represents the approach of the procedure
False
The second character value for the Administration section has three values: 0, C, and F.
False
The third character in the Medical and Surgical section of ICD-10-PCs references the device that is used
False
There are always six characters used for a procedure code in ICD-10-PCS
False
There are two root operations in the Osteopathic section
False
To locate a code in ICD-10-PCS, the coder would first reference the Tables.
False
True or False: A CT scan of the thoracic aorta using high osmolar contrast would be reported using code B2300ZZ.
False
True or False: A nonimaging nuclear medicine probe of the brain using Xenon 133 radionuclide MJB is reported with code C050YZZ
False
True or False: A nonimaging nuclear medicine probe of the brain using Xenon 133 radionuclide MJB is reported with code C050YZZ.
False
True or False: Code 5A02116 reports continuous cardiac output pump assistance.
False
True or False: Hyperthermia means raising of the pulse
False
True or False: In Table 4A0, a function/device character value of R denotes flow.
False
True or False: In Table 7W0, fascial release has a value of 1 in the character 5 position.
False
True or False: In Table 8E0, in vitro fertilization has a qualifier value of 6.
False
True or False: In Table B00, character 5 denotes the body part imaged.
False
True or False: In Table B23, the 3 denotes plain radiography
False
True or False: In code B2210ZZ, the 0 denotes low osmolar contrast.
False
True or False: In table 7W0 the fascial release has a value of 1 in the character 5 position
False
True or False: In the Radiation Therapy section of ICD-10-PCS, the fourth-character value denotes the modality used
False
True or False: In the code B2210ZZ the 0 denotes low osmolar contrast
False
True or False: In the radiation therapy section the fourth character value denotes the modality used
False
True or False: Monitoring, in ICD-10-PCS, is defined as determining the level of a physiological function at a point in time.
False
True or False: Multiple shockwave therapy of the musculoskeletal system is reported with code 6A930ZZ.
False
True or False: Osteopathic treatment is defined as a manual procedure that involves directed thrust to move a joint.
False
True or False: Osteopathic treatment is defined as manual procedure that involves directed thrust to move a joint
False
True or False: Pheresis is the lowering of body temperature.
False
True or False: Physiological devices are denoted in the Measurement and Monitoring section with a third-character value of B.
False
True or False: The first-character value for extracorporeal assistance and performance is 6.
False
True or False: The first-character value in the Measurement and Monitoring section is 5.
False
True or False: The fourth character in the Chiropractic section denotes the approach of the procedure.
False
True or False: The percutaneous monitoring of the intracranial temperature of the central nervous system would be reported with code 4A107KD
False
True or False: There are two root operations in the Osteopathic section of ICD-10-PCS.
False
True or False: he fourth character in the chiropractic section denotes the approach of the procedure
False
True or false: Osteopathic procedures have a first character value of 8.
False
When selecting a code for revision of right shoulder joint, the term to reference in the Index is shoulder.
False
The duration of extracorporeal assistance and performance is denoted with the _____ character of the code.
Fifth
The duration of extracorporeal assistance and performance is denoted with the ________ character of the code.
Fifth
Mental Health procedures are reported with a section identifier of _________.
G
Mental health procedures are reported with a section identifier of _____.
G
In the code 3E083PZ the 8 represents ________.
Heart
In the code 3E083PZ, the 8 represents _____.
Heart
Character 6 in the Radiation Therapy Section of ICD-10-PCS denotes the ________.
Isotopes introduced into the body
Character 6 in the Radiation Therapy section of ICD-10-PCS denotes the _____.
Isotopes introduced into the body
Character 6 in the radiation therapy section denotes the
Isotopes introduced into the body
An appendectomy would be reported in the ___ section
Medical/surgical
In code DG005ZZ, the 5 denotes
Neutrons
In code DG005ZZ, the 5 denotes _____.
Neutrons
OMT is an abbreviation for
Osteopathic manipulation therapy
OMT is an abbreviation for ________.
Osteopathic manipulation therapy
An entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach the site of the procedure is a(n) _________ approach.
Percutaneous
The approach character of 3 in Table 10J represents _____.
Percutaneous
The approach character of 3 in Table 10J represents ________.
Percutaneous
Completely taking over a physiological function by extracorporeal means is known as _____.
Performance
Completely taking over a physiological function by extracorporeal means is known as ________.
Performance
Using light rays during extracorporeal therapy is known as _____.
Phototherapy
Using light rays during extracorporeal therapy is known as ________.
Phototherapy
The sixth character of extracorporeal assistance and performance codes denotes the _____.
Physiological function assisted or performed
Introduction of radioactive materials into the body for single-plane display of images developed from the capture of radioactive emissions is known as
Planar imaging
Introduction of radioactive materials into the body for single-plane display of images developed from the capture of radioactive emissions is known as _____.
Planar imaging
Introduction of radioactive materials into the body for single-plane display of images developed from the capture of radioactive emissions is known as ________.
Planar nuclear medicine imaging
Introduction of radioactive materials into the body for the single-plane display of images developed from the capture of radioactive emissions is known as
Planar nuclear medicine imaging
Introduction of radioactive materials into the body for three-dimensional display of images developed from the capture of radioactive emissions is known as
Planar nuclear medicine imaging
Introduction of radioactive materials into the body for three-dimensional display of images developed from the capture of radioactive emissions is known as _____.
Planar nuclear medicine imaging
Sally Smith is receiving radiation treatment for carcinoma of the left breast. This would be reported with a code from the _____ section.
Radiation Therapy
Sally Smith is receiving radiation treatment for carcinoma of the left breast. This would be reported with a code from the _________ section.
Radiation Therapy
The third character value of M in the Medical and Surgical Section of ICD-10-PCS represents the root operation of _________.
Reattachment
The third-character value of M in the Medical and Surgical Section of ICD-10-PCS represents the root operation of _____.
Reattachment
Which of the following is not a root operation
Removal Control Extraction Incision*
In the Medical and Surgical Section of ICD-10-PCS, the third character value of V is used to indicate the root operation of _________.
Restriction
In the Medical and Surgical Section of ICD-10-PCS, the third-character value V is used to indicate the root operation of _____.
Restriction
A fourth character value of 8 in Table 9WB denotes _____.
Rib cage
A fourth character value of 8 in Table 9WB denotes ________.
Rib cage
A fourth character value of 8 in table 9WB denotes
Rib cage
A fourth character value of 8 in table of 9WB denotes
Rib cage
In the code 7W04X6Z, the 4 denotes _____
Sacrum
In the code 7W04X6Z, the 4 denotes _____.
Sacrum
In the code 7W04X6Z, the 4 denotes ________.
Sacrum
In Table 3E0 the correct value for a substance of a destructive agent is ________.
T
In Table 3E0, the correct value for a substance of a destructive agent is _____.
T
Which of the following is not an example of a tubular body part?
Trachea Small Intestine Blood vessel Liver*
The moving, without taking out, all or a portion of a body part to another location to take over the function of all or a portion of a body part is known as _____.
Transfer
The moving, without taking out, all or a portion of a body part to another location to take over the function of all or a portion of a body part is known as _________.
Transfer
A forceps delivery occurs when an instrument is used to grasp the fetus to assist in the delivery of the baby.
True
A root operation value of 2 in the Administration section of ICD-10-PCS represents the root operation of transfusion.
True
Dr. Smith wanted to determine a pressure reading of the biliary tract for his patient at noon. This is an example of a biliary tract measurement.
True
ICD-10-PCS requires the coder to use the Tables to build codes.
True
In ICD-10-PCS, delivery is defined as assisting the passage of the products of conception from the genital canal.
True
In Table 2W1 there are two values for the device character.
True
In Table 2W1, a character value of P for the body region represents upper leg, left.
True
In Table 2W3, the 3 represents a root operation that limits or prevents motion of a body region.
True
In table 8C0, an external approach has a value of X
True
In the Placement section of ICD-10-PCS, there are two values for the second character, W and Y.
True
In the Placement section, there is only one approach value of X.
True
In the code 3E00XMZ, the M represents the substance introduced into the body
True
Partially closing an orifice or lumen of a tubular body part defines the root operation of restriction
True
Placement of a catheter into an internal site is considered a type of percutaneous approach.
True
Procedures are listed alphabetically in the Index.
True
Root operations reflect the objective of the procedure and would be specified in the third-character position
True
Sally is experiencing excessive bleeding from her nose. Dr. Smith packs her nose to stop the bleeding. This would be coded with a code from the Placement Section of ICD-10-PCS.
True
The first character used to identify the Administration section of ICD-10-PCS is 3.
True
The first four characters used to report a delivery are 10E0.
True
The fourth character values in the Placement section are divided into body regions and natural orifices.
True
The root operation of release is defined as the freeing of a body part.
True
The second character value for the body system of pregnancy is 0
True
The second through seventh characters have different meanings from section to section within ICD-10-PCS
True
The seventh character in the Medical and Surgical section of ICD-10-PCS identifies a qualifier.
True
The use of seven character positions in ICD-10-PCS allows for additional descriptors to be added as new techniques evolve.
True
True or False: A first character value of B denotes imaging
True
True or False: A first-character value of B in ICD-10-PCS denotes imaging.
True
True or False: A is the only value for the second character in both the Extracorporeal or Systemic Assistance and Performance section and the Extracorporeal or Systemic Therapies section.
True
True or False: A robotic-assisted procedure has a value of C in table 8E0
True
True or False: Chiropractic procedures have a first character value of 9
True
True or False: Chiropractic procedures have a first character value of 9.
True
True or False: Code 4B00XVZ would be used to report an external approach measurement of a central nervous stimulator.
True
True or False: Imaging procedures include plain radiology, fluoroscopy, CT, MRI, and ultrasound.
True
True or False: In Table 4A1, the body system of cardiac is represented with a value of 2.
True
True or False: In Table 5A2, the duration is always single
True
True or False: In Table 6A5, extracorporeal separation of platelets is reported with a seventh digit of 2.
True
True or False: In Table 8C0, an external approach has a value of X.
True
True or False: In code B030Y0Z the Y denotes other contrast
True
True or False: In code B030Y0Z, the Y denotes other contrast
True
True or False: In the Measurement and Monitoring section of ICD-10-PCS, a third-character value of 0 represents the root operation of measurement.
True
True or False: In the Nuclear Medicine section of ICD-10-PCS, the third-character value denotes the type of nuclear medicine procedure.
True
True or False: In the Table 5A1, the fourth character of C represents the biliary body part.
True
True or False: In the nuclear medicine section the third character value denotes the type of nuclear medicine procedure
True
True or False: Monitoring the conductivity of the central nervous system would determine the level of physiological function repetitively over a period of time.
True
True or False: The second-character value represents either the physiological system or the physiological device.
True
True or False: There are three root operations for the Extracorporeal or Systemic Assistance and Performance Section of the ICD-10-PCS.
True
True or false: A robotic-assisted procedure has a value of C in Table 8E0.
True
The fifth character value in the Administrative Section of ICD-10-PCS, of 7 represents ________.
Via natural or artificial opening
The fifth-character value in the Administrative section of ICD-10-PCS of 7 represents _____
Via natural or artificial opening
In the code 4A0D7LZ, the L represents _____.
Volume
In the code 4A0D7LZ, the L represents ________.
Volume
In the Chiropractic Table of ICD-10-PCS, the approach always has a value of _____.
X
In the Chiropractic Table of ICD-10-PCS, the approach always has a value of ________.
X
In the chiropractic table the approach always has a value of
X
In Table 4B0 which of following character 7 values are valid?
Z
Character 6 in the radiation therapy section of ICD-1-PCS denotes the
isotopes introduced into the body
In the code DG005ZZ the 5 denotes
neutrons
Removal of packing material from the urethra would be reported with code _____.
2Y55X5Z
Removal of packing material from the urethra would be reported with code _________.
2Y55X5Z
Administration procedures are identified with a section value of
3
Administration procedures are identified with a section value of _____.
3
When coding the removal of a bandage from the foot, the Index lists the first three characters of the code as:
2W5
Which of the following is not a root operation?
*Incision* Extraction Control Removal
The root operation of introduction has a root operation value of _____.
0
The root operation of introduction has a root operation value of ________.
0
The second character value for the Administration section of ICD-10-PCS has a value of _____, which is used to report transfusion procedures.
0
Open drainage of fetal blood from a fetus would be reported with code ________.
10900z9
The approach character of 3 in Table 10J represents ________.
10900z9
A mid forceps delivery would be coded with code _____.
10D07Z4
A mid forceps delivery would be coded with code ________.
10D07Z4
A percutaneous endoscopic inspection of retained products of conception would be reported with code _____.
10J14ZZ
A percutaneous endoscopic inspection of retained products of conception would be reported with code ________.
10J14ZZ
A repair of the ear on a fetus using a percutaneous endoscopic approach, no device, would be coded with code _____.
10Q04ZJ
A repair of the ear on a fetus using a percutaneous endoscopic approach, no device, would be coded with code ________.
10Q04ZJ
A cast change for the right thumb would be reported with code _____.
2W0GX2Z
A cast change for the right thumb would be reported with code _________.
2W0GX2Z
Placement of a pressure dressing on the right finger for compression would be reported with code _____.
2W1JX6Z
Placement of a pressure dressing on the right finger for compression would be reported with code _________.
2W1JX6Z
Placement of a splint on the third left finger would be reported with code _____.
2W3KX1Z
Placement of a splint on the third left finger would be reported with code _________.
2W3KX1Z
Packing of the chest wall using packing material would be reported with code _____.
2W44X5Z
Packing of the chest wall using packing material would be reported with code _________.
2W44X5Z
When coding the removal of a bandage from the foot, the Index lists the first three characters of the code as ______.
2W5
Which of the following would NOT immobilize a fractured arm?
Cast Bandage Splint Stereotactic device
When coding the phrase "right upper extremity cast change due to breakage of cast," the term to reference in the Index is _____.
Change
When coding the phrase "right upper extremity cast change due to breakage of cast," the term to reference in the index is _________.
Change device in or on
Section identifier 9 reports which of the following?
Chiropractic procedures
The section identifier of 9 reports which of the following?
Chiropractic services
In Table 6A1, the only body system represented in the table is ________.
Circulatory
In Table 6A1, the only body system represented is _____.
Circulatory
Which of the following procedures allows for the visualization of a body part?
Colonoscopy
Which of the following procedures allows for the visualization of a body part?
Colonoscopy* Biopsy of liver Appendectomy Needle biopsy of breast tissue
The second character value for the Administration Section of ICD-10-PCS has a value of ________ which is used to report circulatory procedures.
D
In Table 4B0, which of following seventh-character values are valid?
D Z* 5 3
Extracorporeal elimination of undissolved gas from body fluids defines ______.
Decompression
Extracorporeal elimination of undissolved gas from body fluids defines:
Decompression