The load for each small-appliance, branch circuit load is required to be calculated at ____.

1,500 volt-amperes

The maximum overcurrent protection for ____ AWG copper conductors is 30 amperes.

10

The recommended approach to provide adequate lighting in a residential garage is to install one ____-watt lamp on the ceiling above each side of an automobile.

100

The minimum depth for a 120-volt, 15-ampere, GFCI-protected circuit to an outdoor pole light run under a paved driveway is ____.

12 inches

Roughing-in recessed luminaires that will be installed between ceiling joists can be quite a challenge. The conflict is between the ____ in. on center joists and the 24 in. square acoustic ceiling panels and their metal "T" bars and supports.

16

The NEC permits all bathroom receptacles to be on a single ____ branch circuit so long as it doesn't supply other loads.

20-ampere

A receptacle below a 4-way switch in the corner of a living room is required because the Code requires that a receptacle be installed in any wall space ____ in. or more in width.

24

Ceiling-suspended paddle fans must not be located within a zone measured ____ horizontally and ____ vertically from the top of the bathtub rim or top of a shower stall threshold.

3 ft (900 mm); 8 ft (2.5 m

Prior to the 1996 NEC, ____ receptacles and cords were permitted. However, now it is mandatory that a separate equipment grounding conductor be installed to ground the frames of electric clothes dryers and electric ranges.

3 wire

Electric washer/dryer combinations generally require a ____-ampere branch circuit similar to that required for a typical electric clothes dryer.

30

A fixture whip is ____ ft (1.2 to 1.8 m) long and is installed between the junction box and the luminaire.

4 to 6

Some inspectors consider the area within a ____-degree angle from a roof line or overhang to be a damp location.

45

Lighting track is not permitted to be installed less than ____ above a finished floor unless it is protected against physical damage, or if the track is of the low-voltage type operating at less than 30 volts rms open-circuit voltage.

5 feet

A doorjamb switch is usually mounted about ____ feet above the floor, on the inside of the 2 x 4 framing on the hinge side of the closet door.

6

The NEC fill calculations for a conduit nipple not over 24 in. (600 mm) allows what fill percentage for three or more conductors?

60%

The most common type of dimmer used in residential applications is rated ____ watts, 125 VAC, 60 hertz

600

Cord-and-plug-connected appliances shall not exceed ____ percent of the branch-circuit rating.

80

The derating factor that must be used when four to six current-carrying conductors are installed in a conduit is ____ percent.

80

A 125-volt, 15- and 20-ampere receptacle installed to serve a kitchen countertop is required ____.

: a. to be supplied by at least two 20-ampere small appliance circuits b. to have GFCI protection for personnel Correctd. both a and b

What type of cable is permitted to be used for direct burial applications?

Type UF

When someone decides to use a bedroom as a home office instead, ____.

a lot of electronic equipment will have to be plugged in

GFCI protection can be provided for convenience receptacles serving kitchen countertop areas by ____.

a. GFCI circuit breakers b. installing a GFCI-protected receptacle at each location c. installing a single feed-through type GFCI receptacle to protect downstream receptacles d. all of the above

Portable lighting track must meet which of the following requirements?

a. It shall not be longer than 8 feet. b. It shall have have a cord not less than 5 feet permanently attached to the track. c. It shall have overcurrent protection (fuse or circuit breaker) built into the plug cap. d. All of the above

A "unit switch" used as a disconnecting means for an electric clothes dryer shall ____.

a. be horsepower-rated b. disconnects all the conductors in the appliance d. both a and b

Which of the following is required in order to dim fluorescent fixtures?

a. fluorescent dimmer b. dimming ballasts d. both a and b

Electronic dimmers use triacs to chop the ac sine wave, so some incandescent lamps might ____ because the lamp filament vibrates.

a. hum

Lighting track in residential installations must not be installed ____.

a. in damp or wet locations b. concealed c. through walls or partitions d. all of the above

When a luminaire is connected to the conductors, the outlet is referred to as a ____ outlet.

a. lighting

The advantage(s) of pull-chain switches for lighting fixtures include ____.

a. local control of task lighting b. energy conservation d. both a and b

To ensure that the conductor insulation will not be injured, be sure to ream the cut ends of rigid conduit and electrical metallic tubing to remove ____.

a. rough edges c. burrs d. both a and c

The NEC requires that an appliance nameplate show ____.

a. the appliance rating in volts and amperes c. the appliance connected load in volts and watts d. either a or c

In accessible attics, exposed cables must be protected by guard strips when ____.

a. they are run across the top of joists b. they are run across the face of studs c. they are installed within 7 feet of the floor or floor joists d. all of the above

Receptacles installed within 6 feet of a wet bar are required ____.

a. to have GFCI protection b. to not be installed face up in countertops or work surfaces d. both a and b

In addition to being fastened to the outlet box, the track for track lighting is generally fastened to the ceiling with ____.

a. toggle bolts b. screws d. both a and b

In a room that may be used as a home office, you could consider ____.

a. using 12 AWG for the home run or even for the entire branch circuit(s) b. wiring in quadplex receptacles instead of duplex receptacles c. using only plug-in strips that are UL listed d. All of the above

All 15- and 20-ampere receptacles installed within 6 ft (1.8 m) of a ____ sink must be GFCI protected.

a. wet bar b. laundry c. utility d. all of the above

When using nonmetallic boxes, the volume allowance is based on ____.

a. wiring devices b. cable clamps c. equipment grounding conductors d. all of the above

Lighting fixtures marked "Recessed Fluorescent Luminaire" ____ permitted to be installed in a suspended ceiling.

are

Outdoor lighting fixtures and associated equipment ____ permitted to be supported by trees.

are

Raceways ____ required be installed as a complete system between pull points before pulling in the wires.

are

A bathroom is defined as "an area including a basin, with one or more of the following: ____.

are not

According to NEC 406.9, receptacles ____ permitted to be installed in bathtub and shower spaces.

are not

Overhead conductors ____ permitted to be supported by trees.

are not

NEC 210.70(A)(3) addresses ____ that are used for storage and attics that contain equipment that might need servicing, such as air-conditioning equipment.

attics

As defined in Article 100, a bathroom is required to have a ____.

basin

Many workshop fluorescent luminaires are furnished with a 3-wire (____) flexible cord suitable for the purpose that has the attachment plug cap factory-attached to the cord.

black, white, green

Most duplex receptacles can be changed into "split-wired" receptacles by ____.

breaking off the small metal tab on the terminals

A(n) ____ receptacle can be hidden behind a painting or photograph that you want to light up.

clock hanger

What piece of kitchen equipment is permitted to be connected to the two 20-ampere small-appliance circuits required for the kitchen and dining room area?

clock outlet

For most residential electric ____, receptacles and cord sets are rated 30 amperes, 125/250 volts.

clothes dryers

Metallic conduit buried underground must be protected against ____.

corrosion

NEC 410.10(D) ____ lighting track to be located within a zone measured 3 ft (900 mm) horizontally and 8 ft (2.5 m) vertically from the top of a bathtub rim or top of a shower stall threshold.

does not permit

With ____ products, it takes two failures to create a shock hazard to the user.

double-insulated

Conductors in a ____ fixture whip in a typical suspended ceiling "lay-in" fluorescent luminaire must have a temperature rating as required on the label in the luminaire.

flexible

Because of the dangers associated with the open neutral (grounded conductor), NEC 300.13(B) does not permit the continuity of the ____ conductor to depend on a receptacle.

grounded (neutral)

A(n) ____ is NOT an acceptable disconnecting means for appliances.

horsepower-rated switch

NEC 422.16(B)(4) permits a range hood to be cord-and-plug connected. The receptacle would be installed ____ the range.

inside the cabinetry above

Kitchen lighting ____ permitted to be supplied by the two 20-ampere small-appliance circuits required for the kitchen and dining room area.

is not

Lighting track ____ permitted to be installed within a zone extending 3 feet horizontally and 8 feet vertically from the top of a bathtub rim.

is not

The branch circuit feeding the required laundry receptacle ____ permitted to supply other dedicated equipment in the laundry room, including lighting and an exhaust fan.

is not

Type UF "underground feeder" cable ____ permitted to be used to supply service entrances.

is not

When a single receptacle of any rating is installed on an individual branch circuit, the receptacle rating must not be ____ than the rating of the branch circuit.

less

Lighting track in residential installations shall not be cut to length in the field unless permitted by the ____.

manufacturer

Lighting fixtures intended for installation in wet locations must be ____.

marked "Suitable for Wet Locations"

Recessed or surface-mounted luminaires and recessed exhaust fans ____ be located within the restricted zone near the bathtub.

may

When designing a home office, you could consider roughing in more wall receptacles than the NEC ____.

minimum

When outdoor receptacles are installed where a cord will be plugged in permanently, such as for decorative lighting, the box cover ____ maintain weatherproof integrity when the cord is plugged in.

must

When a nonmetallic wiring method is installed where short sections of metal raceway are provided for mechanical protection—or for appearance—these short sections of raceway ____ be grounded.

need not

The circuit feeding the required laundry area receptacle(s) shall have ____ outlets connected to it.

no other

In many parts of the country, the wiring method in unfinished basements is ____ in the ceiling and EMT on the walls for receptacles and switches.

nonmetallic-sheathed cable

According to NEC 210.52(G), at least ____ receptacle(s) must be installed in an attached residential garage.

one

The NEC defines a kitchen as an area with a sink and ____ provisions for food preparation and cooking.

permanent

When an existing dryer or electric range is replaced, the NEC ____ the grounded conductor of an existing individual branch circuit to be used for grounding the appliance frame.

permits

Some additional rules apply when nonmetallic-sheathed cable and armored cable are ____, because of possible physical damage to the cables.

run exposed

The NEC requires that all 125-volt, ____, 15- or 20-ampere receptacles installed in unfinished basements must be GFCI protected.

single-phase

Two popular types of electronic dimmers are ____.

slide and rotate

The sound level rating used to define fan noise is expressed in ____.

sones

To provide shock protection, low-voltage wiring systems are required by Article 411 to be ____.

supplied through isolating transformers

In many cases, the use of a multiwire branch circuit can save money in that one 3-wire branch circuit will do the job of ____ branch circuits.

two 2-wire

Countertop receptacles must be served by at least ____-ampere small appliance circuits.

two 20

Some portable appliances use double insulation in place of grounding to provide shock protection to users. Double-insulated appliances normally have ____ power cords and attachment plug caps.

two-wire

The 125-volt, 20-ampere receptacles installed to serve kitchen countertops are required to have GFCI protection ____.

under all circumstances

In a home office, the current draw is ____.

very low

A location exposed to the weather is a ____ location.

wet

Install luminaires listed for ____ locations if they will be subject to shower spray.

wet


Conjuntos de estudio relacionados

Encyclopedia of Counseling Chapter 10

View Set

Professional Communications Quiz 3

View Set

English GCSE NORA THE FRIENDLY ZEBRA MAKES STRUCTURE REALLY EASY PEASY

View Set

Project Management Chapter 8 Questions

View Set

WEEK 1 CUSTUM EXAM LPN NURSING PROCESS

View Set

Coursera - Course Three - Unit 2

View Set