A man lift breaks down outside the FHR Maintenance; in order for repairs to commence what must be locked out prior? (FHSP-004.8) Battery Cable, Battery cable lockout device Ignition, prove tag Gas pedal, Gas pedal club lock. Gear shift, motorized equipment tag.

Battery Cable, Battery cable lockout device

What type of lock should be the first-on and last-off the project lock box? (FHSP-004.7) Yellow American Series 1105 Red Abus Series 7240 Black American Series 1105 Black Abus Series 7240

Black Abus Series 7240

All Soil on FHR Corpus Christi Complex is classified as Type ____. (FHSP-005) C A B

C

The protection factor of a quantitively fit tested full face air purifying respirator is 50 and the eight hour allowable limit for benzene is 0.5 ppm. What benzene ppm can the respirator provide protection to? A. 50 ppm B. 10 ppm C. 25 ppm D. 35 ppm

C. 25 ppm

At what temperature must be internal ambient temperature in a confined space be managed? A. 95-99 B. 94 C. >100 D. 90

C. >100

How many bolts are required on a blind flange for confined space entry preparation. A. 8 B. 4 C. All bolts D. Hot bolt

C. All bolts

An IDLH atmosphere in a confined space is defined as what? Life critical definitions job aid A. And initially delayed life hazard where exposure times of less than one hour can be dangerous B. Confined space areas that are cleared for entry by FHR personnel C. An atmosphere where an exposure time of less than 30 minutes could result in recordable injury or illness D. An area that is cleared by Safety for continuous entry

C. An atmosphere where an exposure time of less than 30 minutes could result in recordable injury or illness

How often should PPE be inspected?FHSP-034 A. Weekly B. Daily C. Before each use D. After each use

C. Before each use

When is initial Mercury monitoring of a confined space required? FHSP 073 A. Only in units where Mercury has been found in the past B. Only required during turnarounds C. Confined spaces in hydrocarbon service D. Every confined space

C. Confined spaces in hydrocarbon service

Which of the following best describes an entry supervisor? FHSP 002 A. Health and safety technician responsible for the area B. Employee that signed onto the crew section of the permit C. Employer, Forman, or safety lead responsible for determining if acceptable entry conditions are present at a permit space where entry is planned D. Confined space attendant that is properly trained

C. Employer, Forman, or safety lead responsible for determining if acceptable entry conditions are present at a permit space where entry is planned

If it is possible 4 N employee to be surrounded or captured by liquid or flowing solid substance that could result in suffocation, strangulation, constriction or crushing it would be considered what type of hazard? Life critical definitions job aid A. Emergency B. IDLH C. Engulfment D. Inert

C. Engulfment

A confined space is a work area that has the following characteristics FHSP 002 A. Has a minimum of 4 entry an access points B. Is a square shape to avoid gas pockets C. Has limited or restricted means for entry or exit D. Is large enough so that an employee can enter to perform work E. Is not designed for continuous employee occupancy F. Fits into define internal volume limits or confined space entry

C. Has limited or restricted means for entry or exit D. Is large enough so that an employee can enter to perform work E. Is not designed for continuous employee occupancy

How many times must be confined space be re-monitored during one standard 12 hour shift? A. Three times in a 12 hour shift B. Two times C. It is not a requirement to re-monitor confined spaces with a multi gas monitor after the initial reading D. Four times

C. It is not a requirement to re-monitor confined spaces with a multi gas monitor after the initial reading

Who completes rescue pre-plans for confined space entries? FHSP-002 A. Operations B. ERT C. RTFC D. Safety department

C. RTFC

If a task in a confined space requires breeding here and the LEL rises past 2%, what must occur? FHSP-002.1 A. Re-calibrate monitoring equipment to achieve zero B. Check readings with a different meter C. Remove occupants from space D. Add additional ventilation

C. Remove occupants from space

Who can take bulk samples of suspect Mercury containing materials? FHSP-073 A. Lab employees B. FHR employee or contractor C. Trained hazardous material technician D. RTFC employee

C. Trained hazardous material technician

Which of the following is required PPE when performing a " First Break" on chemical/ hydrocarbon process? (FHSP-038) Check All That Apply: Chemical Gloves Full Chemical Suit Supplied-Air Respirator Chemical Boots H2S Monitor

Chemical Gloves Full Chemical Suit Supplied-Air Respirator Chemical Boots

What meter should be used and where should test or plumbers' plugs be assessed to ensure no leakage? (FHSP-006.4) Hydrogen meter, vent hose Combustible Gas, Bleeders around the plug. Combustible Gas, Circumference of plug & each threaded connection The contractor undertakes this task with a specialized meter.

Combustible Gas, Circumference of plug & each threaded connection

A contractor request a permit to dig and excavation and then perform work at a depth of 5 feet. What is required for the work to be completed? FHSP-002 / FHSP-005 A. FHSF-010 excavation obstruction form B. The excavation becomes a confined space C. Sloping or shoring of the excavation D. All of the above

D. All of the above

If repairs on a man lift do not finish before the end of the shift what must be done? (FHSP-004.8) Tow the equipment to a safe location where repairs can continue the next shift. Pass the keys to the equipment over to the night PL. Remove all energy control and end the shift. Place a " Do not operate tag" on the energy control device.

Place a " Do not operate tag" on the energy control device.

What type of barricade are acceptable during the course of work involving a radiation source? (FHSP-015) Red danger tape Green tape labled "radioactive" Yellow caution tape Purple and yellow rope with signs every 20 feet.

Purple and yellow rope with signs every 20 feet.

If a crew needs to preform work inside a vessel with a radiation source attached to it, who should you contact? (FHSP-015) Radiation Safety Officer Office of Radiation Safety Radioactive Situation Office Receiving Source Operation

Radiation Safety Officer

The Permit Writer must ensure that the Industrial Radiographer has which of the following before issuing a Safe Work Permit to perform work involving the use of radiation? (FHSP-015) Check all that apply: Potassium Iodide supplements Radiation survey meter with appropriate calibration and labeling Portable Radio

Radiation survey meter with appropriate calibration and labeling Portable Radio

What is the only lock that FHR uses for locking out Energy Isolation Devices? (Life Critical Definitions) Red Abus Series 7240 Black Abus 7240 Red American Series 1105 Green American Series 1105

Red Abus Series 7240

Who is responsible for supporting and providing resources (staffing, policies, procedures, and programs) that promote Refinery Safety, Health Environmental processes? (FHSP-000) Safety and Health Department Environmental Department Supervisors Refinery Management

Refinery Management

If an immediate health, safety or environmental hazard is found what must be done? (FHSP-000) Communicate hazard to safety lead, do nothing else. Report to supervisor for mitigation. Ignore hazard; someone else has already seen it Inform fellow employee of hazard so he can manage it.

Report to supervisor for mitigation.

Where should the Energy Control Log Sheet be placed at the completion of energy control work? (FHSP-004.1) Deliver to RC Safety Technician Return the Energy Control/Blinding log sheet to the "Completed" permit box for retention. Trash- the Energy Control Log Sheet is no longer needed Return to PL's office

Return the Energy Control/Blinding log sheet to the "Completed" permit box for retention.

What respiratory protection devices are currently approved for usage provided a fit test for the specific respirator has been done. (FHSP-003) 3M Breathe Hard Scott AV-2000 Scott AV-6000 3M Breather Easy

Scott AV-2000

Which of the following are FHR approved methods for protection against cave-ins? (FHSP-005) Check all that Apply: Sloping Benching Shielding Shoring All of the above

Sloping Shielding Shoring

A copy of the MSDS shall be attached to the permit for all first break? (FHSP-038) FALSE TRUE

TRUE

During off hours the Permit Writer, Safety Lead, and Production Lead will perform a Prove step verification; however, a fourth signature is not required. (FHSP-004.1) FALSE TRUE

TRUE

In order for a rigid coupling to be removed from a vertical pump, the pump case must be locked out and de-pressurized. (FHSP-004.5) TRUE FALSE

TRUE

When energy control is temporarily removed for the purpose of testing and positioning, the safety lead or authorized craft employee is required to maintain control of energy at the equipment until normal energy control is re-applied? (FHSP-0034.2) TRUE FALSE

TRUE

When noting the type of magnitude of energy on the Energy Control Blinding Log Sheet must use the energy that existed prior to isolation? FHSP-004.6) FALSE TRUE

TRUE

When are Calobar lenses required in safety eye wear? (FHSP-019) The employee is working within 10 feet of welding or gouging Work will produce particulate or flying debris The employee requires a prescription safety lenses The sun is shining more than 8 hours a day

The employee is working within 10 feet of welding or gouging

A contractor contacts you for a permit to perform hydrotesting on equipment. They will be using hand tools and a pneumatic hydrotesting machine. They will need a truck to enter the unit this permit should be written as a? (FHSP-006.1) Basic Level Hot Work Safe Work Only Basic Level Hot Work, Confined Space. Master Level Hot Work

Basic Level Hot Work

At what depth is an "Excavation Obstruction Identification Form" required and who must a contractor contact to require it? (FHSP-005) 18 inches, Projector Manager 36 inches, Project Manager 12 inches, Project Engineer 36 inches, Project Engineer

12 inches, Project Engineer

What is the minimum barricade distance for a first break? (FHSP-038) 30 feet 10 feet 15 feet 25 feet

15 feet

A harness and lanyard are required when the employee is working _____ over grade when not on engineered walkways, platforms, or landings. (FHSP-033) 4 Feet 10 Feet 12 Feet 6 Feet

4 Feet

Criteria used to determine acceptable temporary fabrication areas include: (FHSP-006.5) Clearly defined area and ownership. Adequate distance from process areas and lack of combustible material Sufficient auditing availability Adequately hard barricaded area A and B

A and B

Which of the following is required when performing a minor servicing task? (FHSP-004.4) Open Bleeder Tag Isolation Blind Tag Minor Servicing Tag A and C

A and C

A contractor comes in to acquire a permit for work that will be within six feet of the leading edge of the top of a vessel with no guardrails. What options are available to mitigate the fall risk? (FHSP-033) No fall protection is required if employee is not approaching within four feet of the leading edge. No fall protection is required if the contractor is leading edge certified A fall protection system must be used Contract forman can determine if fall protection is required.

A fall protection system must be used

What must you do if testing and positioning will occur multiple times (FHSP-004.2) A. Attach the additional log sheet FHSF-022 found on the health and safety info center, and check the box on the permit stating that the attachment form is in use. B. Issue a new save work permit C. Allowed testing of equipment to occur multiple times under the same energy control removal step D. Update the permit to state that testing and positioning occurred more than once

A. Attach the additional log sheet FHSF-022 found on the health and safety info center, and check the box on the permit stating that the attachment form is in use.

The safety lead may also double as the confined space attendant. FHSP-002.1 A. FALSE B. TRUE

A. FALSE

A confined space is open for the first time. Benzene is common with in the process. The first snip indicates a reading of 3 PPM Benzene. what is the minimum respiratory equipment required to work in or around the benzene regulated area? FHSP-012 A. Full face air purifying respirator with organic vapor cartridges B. Supplied air respirator C. Deny entry until benzene is cleared from unit D. Respiratory gear is not required for this amount

A. Full face air purifying respirator with organic vapor cartridges

If you are breaking into a line that has 60 ppm benzene, what would be the correct respirator protection? FHSP-012 A. Full face with supplied air B. Full face with OV/AG cartridges C. Normal PPE D. Dust mask

A. Full face with supplied air

What level of permit writer certification is needed to issue the first confined space permit for a vessel or tower? FHSP-002 A. Master Level B. Master Plus C. Basic Level

A. Master Level

When form FHSF036 is used to cut a line, after the cut how do you ensure that there will be no leaks or venting to atmosphere? A. Plumbers plug B. Duct tape C. Do nothing as the hazard has been medicated D. Weld a flange on and blind

A. Plumbers plug

If the oxygen reading on the monitor dips below or above allowable levels, what should occur immediately after? FHSP-006.2 A. Remove all personal from the space B. Go inside the space to check for yourself C. Equip all workers with supplied air D. Contact RTFC

A. Remove all personal from the space

How does one determine the appropriate level of PPE for a safe work permit in an area with a known hazard substance? FHSP-011 A. SDS or hazardous chemical summary B. Process leader makes this decision C. Word of mouth D. The contractor provide this data

A. SDS or hazardous chemical summary

When may an FHR authorized employee enter a confined space? FHSP-001 / FHSP-002.1 A. The employee is signed on to the Permit, confined space trained and locked out on the project or satellite lockbox B. FHR authorized employee may enter any space at any time as they supersede the contractor requirements C. Everyone inside the space has evacuated D. FHR is noted as a participant company on the Permit

A. The employee is signed on to the Permit, confined space trained and locked out on the project or satellite lockbox D. FHR is noted as a participant company on the Permit

Before a vessel that is equipped with nuclear level gauges maybe entered. FHSP 002 and FHSP 004 .1 A. The gauging devices must be identified and locked out per FHR's energy control policy B. Devices that are located 50 feet or more above grade are not subject to energy control policies C. Gamma radiation sources must be physically removed from the tank

A. The gauging devices must be identified and locked out per FHR's energy control policy

When permitting photographic equipment, you may use the ____ method in-lieu of a five-gas meter. (FHSP-006.1) AVO-Amplitude Versus Offset Tiger Meter Outside Evaluation AVO- Audio, Visual, Olfactory

AVO- Audio, Visual, Olfactory

When permitting photographic equipment what method is used in lieu of a five-gas meter and what does it stand for? (FHSP-006.1) Outside Evaluation AVO-Amplitude Versus Offset Tiger Meter AVO-Audio, Visual, Olfactory

AVO-Audio, Visual, Olfactory

"Standard Required PPE" refers to: (FHSP-034) FRC Clothing Hard Hat Safety Glasses Ear Plugs Steel or Composite toe boots All of the above

All of the above

Which of the following best describes an Authorized Production Employee? ( Life Critical Definitions) A trained individual stationed outside the confined space who monitors the entrants and who performs all attendant duties An employee whose job requires him/her to operate or use a machine or equipment on which servicing or maintanance work is being perfomed under lockout or tagout, or whose job requires him/her to work in an area in which such servicing and /or maintenance work is being performed. An employee who locks out or tags out machines or equipment on which they are qualified to operate and performs servicing or maintenance on machines or equipment on which energy control is required. An employee or contractor that performs servicing or maintenance on machines or equipment on which energy control is required.

An employee who locks out or tags out machines or equipment on which they are qualified to operate and performs servicing or maintenance on machines or equipment on which energy control is required.

Which of the following best describes an Affected Employee? ( Life Critical Definitions) Any non-FHR person who is FHR premises under contract for business purposes, or anyone providing materials, personnel, or services that directly benefit FHR and relate to a contract or subcontract. The contract may be with FHR or another contractor who is working on FHRs behalf. An employee or contractor that performs servicing or maintenance on machines or equipment on which energy control is required. An employee whose job requires him/her to operate or use a machine or equipment on which servicing, or maintenance work is being performed under lockout or tagout, or whose job requires him/her to work in area in which such servicing and/or maintenance work is being performed. An employee who locks out or tags out machines or equipment on which they are qualified to operate and performs servicing or maintenance on machines of equipment on which energy control is required.

An employee whose job requires him/her to operate or use a machine or equipment on which servicing, or maintenance work is being performed under lockout or tagout, or whose job requires him/her to work in area in which such servicing and/or maintenance work is being performed.

When a professional engineer is used to design a protective system for an excavation, a plan indicating the size, type, and configuration(s) of the material to be used in the protective system must be identified on the plan. A copy of the design must remain _______ until the excavation is complete. (FHSP-005) At the Safety Department With the competent Person At the excavation site With the Permit Writer

At the excavation site

Which of the following best describes the process of measuring the content of an environmental to ensure atmospheres are safe for hot work and /or confined space entry? (Life Critical Definitions) Process Overview Area Monitoring Field Walk-Down Atmosphere Testing

Atmosphere Testing

Who assumes responsibility for energy control when testing and positioning is being performed? (FHSP-004.2) Authorized Craft Employee Authorized Production Employee Safety Lead Crew Foreman

Authorized Craft Employee

Who must sign the "Prove" tag prior to issuing the safe work permit? (FHSP-004.1) RC Safety Technician Production Lead or Designee and FHR Craft lead or designee and/or the contractor supervisor. Authorized Production Employee and Safety Lead Crew Foreman

Authorized Production Employee and Safety Lead

A confined space has been found to have an atmosphere of 26.5 ppm benzene. All administrative actions have been used and engineered methods exhausted. At a minimum, what respiratory report Tection all administrative actions have been used and engineered methods exhausted. At a minimum, what respiratory protection must the occupants wear? FHSP-012 A. Dust mask B. Full face with supplied air C. Full face with OV/AG cartridge D. Double current ventilation and allow entry

B. Full face with supplied air

Emergency removal of energy control devices should be performed only when. FHSP 004.3 A. The device to which the energy control device is applied has not been in use for more than 5 years B. It is the only option C. It is the easiest option D. It is the path of least resistance

B. It is the only option

What level of permit writer certification is needed to authorize an Inert Entry Permit? A. Basic Level B. Master Level with FHR Safety Representative co-sign after FHSF 065 review C. Master Level

B. Master Level with FHR Safety Representative co-sign after FHSF 065 review

When monitoring a confined space with a multi gas meter it may take several seconds for the meter to register correctly. FHSP-002.1 A. FALSE B. TRUE

B. TRUE

If you are breaking into a line that has 30 PPM benzene, what would be the minimum respiratory protection? FHSP 012 A. dust Mask B. full face with supplied air C. normal PPE D. full face with OV AG cartridges

B. full face with supplied air

Which of the following best describes an affected employee? Life Critical Definitions A. An employee or contractor that performs servicing or maintenance on machines or equipment on which energy control is required B. An employee who locks out or tags out machines or equipment on which they are qualified to operate and performs servicing or maintenance on machines or equipment on which energy control is required C. Any non-FHR person who is on FHR premises under contract for business purposes, or anyone providing materials, personnel, or services that directly benefit FHR and relate to a contract or subcontract. The contract may be with FHR or other contractor who is working on FHR's behalf D. An employee whose job requires him or her to operate or use a machine or equipment on which servicing or maintenance work is being performed under lock out or tag out, or whose job requires him or her to work in an area in which such servicing or maintenance work is being performed

D. An employee whose job requires him or her to operate or use a machine or equipment on which servicing or maintenance work is being performed under lock out or tag out, or whose job requires him or her to work in an area in which such servicing or maintenance work is being performed

A crew will be performing welding on process equipment, where should the ground lead be placed prior to the start of the welding? FHSP-006.2 A. On metal material that's connected to the equipment to be welded. B. Near the base of the material to be welded. C. On a ground rod near the work. D. As close as possible to site of weld

D. As close as possible to site of weld

If a line must be cut and the LEL reading is below 10%, but not the required 0%, what authorization form is required? FHSP 006.2 A. FHSF 014 B. FHSF 044 C. FHSF 035 D. FHSF 036

D. FHSF 036

Which of the following best describes the preferred method of confined space ventilation? FHSP-002.1 A. Natural ventilation of 120 foot tower B. Forced exhaust ventilation using coppus blower C. Forced ventilation using an air horn at entry way D. Forced intake into vessel using a coppus blower

D. Forced intake into vessel using a coppus blower

After equipment has been blinded in preparation for permitting a contractor to perform master level hot work what should follow? FHSP-006.2 A. Contact Safety department B. Issue appropriate PPE C. Determine if JSA is adequate D. Test lines, vessels and equipment with five gas meter

D. Test lines, vessels and equipment with five gas meter

A crew needs lighting for the interior of a confined space, it should be: FHSP-002.1 A. 12 V with the voltage inverter located outside the space B. Hooked up to a generator of applicable strength inside the space C. 120 V connected to a GFCI outside the space D. Battery powered and of the lowest sufficient voltage E. A and C

E. A and C

Which of the following statements is not correct? (FHSP-033) Any tools or materials necessary to perform a task must be placed within a tool belt or hauled up in a separate container. Employee are required to have three points of contact when ascending or descending a ladder. Electric power lines, air hoses, tag lines or welding leads must not be routed inside a ladder cage. Employees may perform work outside the boundaries of a ladder cages without fail protection provided they are supported by the ladder rungs and ladder cage.

Employees may perform work outside the boundaries of a ladder cages without fail protection provided they are supported by the ladder rungs and ladder cage.

Energy control verification locations are required to be marked with a(n) _____ during minor servicing activities. (FHSP-004.4) Open Bleeder Tag Entry Tag "Prove" Tag Safe Tag

Open Bleeder Tag

Pick the answer that does not go with the following statement: FHR will provide training to ensure that the requirements of excavations and drilling operations are understood by employees? (FHSP-005) Employees will be trained on their responsibilities and the importance of this procedure Employees will be trained on identifying a job that requires an excavation permit. Employees will be trained on how to direct "Emergency Trench Rescue" and the responsibilities of that role.

Employees will be trained on how to direct "Emergency Trench Rescue" and the responsibilities of that role.

What form is used to convey the type and magnitude of energy involved with the job or task? (FHSP-004.1) Authorized to work on In-service equipment. Energy control / Blinding Log Sheet Job Safety Analysis Safe Work Permit

Energy control / Blinding Log Sheet

What materials need to be placed in the unit/project lock box? (FHSP-004.1) Energy Control Locks and energy control approvals form. Safe work permit copy, job safety analysis, blind tag top portion. P & IDs, blind tap coupons, safe work permit. Energy control lock keys, blind tag coupons, energy control blinding log sheet.

Energy control lock keys, blind tag coupons, energy control blinding log sheet.

Which ONE of the following is a part of the FHR policy for "Excavated Material": (FHSP-005) Excavated material must NOT be piled within 5 feet of a line with moving product. Excavated material must be accumulated in a waste bin and tagged as such. Excavated material can be placed anywhere provided there is a pile watch. Excavated material will be placed no closer than two (2) feet from the edge of the excavation.

Excavated material will be placed no closer than two (2) feet from the edge of the excavation.

A basic level permit writer can issue a permit for using a hand hack saw or wheeled pipe cutter to cut a line that contains flammable or combustible material? (FHSP-006.1) FALSE TRUE

FALSE

A welding job can be relocated outside of a process area and permitted by a Basic Level Permit Writer? (FHSP-006.2) FALSE TRUE

FALSE

The operator is allowed to break line-of-sight with the minor servicing job areas? (FHSP-004.4) FALSE TRUE

FALSE

There is a lock out device available for gate valves but not quarter turn valves? (FHSP-004.7) FALSE TRUE

FALSE

In the event a personal lock, unit energy isolation lock or unit energy control device must be forcibly removed, ______ must be competed and submitted to the RC safety Representative. (FHSP-004.3) FHSF-021 FHSF-015 FHSF-001 FHSF-013

FHSF-015

What form must be attached to the permit if testing and positioning is to occur more than once? FSHF-032 Energized Work Permit No other form required FSHF-021 Energy Control Verification Log Sheet FSHF-022 Testing and Positioning Addendum

FSHF-022 Testing and Positioning Addendum

Which FHSP best describes employee roles and responsibilities to ensure the safety and health of FHR employees, contractors and neighbors, and to protect the environment according to applicable rules and regulations? FSHP-000 FSHP-032 FSHP-001 FSHP-021

FSHP-000

When working in an area that contains low amounts of a hydrocarbon air contaminant like toluene or xylene _______ cartridges should be used. (FHSP-003) Organic Vapor Methylamine Ammonia Acid Gas

Organic Vapor

Which of the following best describes the term Decontaminated? (FHSP-038) A mechanical device that physically prevents the transmission or release of energy Piping or equipment that is completely drained and de-pressurized Physical separation or opening of any piping or equipment Connected to an energy source or containing residual or stored energy

Piping or equipment that is completely drained and de-pressurized

At Flint Hills Resources what meter is used to measure radiation and what unit is that radiation measured in? (FHSP-015) Geiger Counter, Milligrays Geiger Counter, Millirems Thyroif Scans, Rads Radiometer, Sieverts

Geiger Counter, Millirems

What level of Permit Writer Certification is needed to authorize a confined space permit? ( Life Critical Definitions) Master Level Basic Level Master Plus

Master Level

A basic level hot work permit can be issued after the authorized production employee uses which of the following to survey the work area? (FHSP-006.1) Mercury vapor meter Personal H2S monitor. Multi-gas detector with LEL sensor Tiger-meter

Multi-gas detector with LEL sensor

The prove step ____. (FHSP-004.1) Exists to provide awareness to the operations department of energy control work. Must be performed on each potential energy source applicable to the equipment being lock out. Needs only to be verified and signed-off by Permit Writer and Production Leader, Safety Lead is not involved. Can be completed after signing the energy control verification section of the safe work permit.

Must be performed on each potential energy source applicable to the equipment being lock out.

Is it acceptable to pass a radioactive barricade while work is in progress? (FHSP-015) Yes No

No

When working at height what are the characteristics of a proper tie off? (FHSP-033) Steam carrying piping, 1-inch in diameter Non-insulated piping, 3 inches in diameter Insulated piping, 2 inches in diameter Employees may not tie off to any piping regardless of diameter.

Non-insulated piping, 3 inches in diameter

Before shutting down equipment and after completing the energy control/binding log sheet what must be done? (FHSP-004.1) Notify all affected employees that the specific piece of equipment will be under energy control. Control all energy sources with applicable locking devices. Release stored energy. Verify equipment is locked out, isolated and de-pressured.

Notify all affected employees that the specific piece of equipment will be under energy control.

What activities are covered by the Minor Servicing Job Aid? (FHSP-0034.4) Check All That Apply: Oil Changes on pumps/turbines Tasks Outlined in Toolbox Procedure I-034 Filter changes and pump screen cleaning Cleaning heater burner tips. Pump maintenance Steam trap maintenance

Oil Changes on pumps/turbines Tasks Outlined in Toolbox Procedure I-034 Filter changes and pump screen cleaning Steam trap maintenance

How many times can a permit be updated? (FHSP-001) Once Three Times Never, once signed the permit cannot be altered Twice

Once

During complex energy control ( Turnaround), after initial zone verification has occurred, how many energy control verification signatures are needed on the Safe Work Permit? (FHSP-004.10) One: Permit writer only; the system is protected via the energy control blinding log sheet. Two-permit writer and Safety lead; anytime during the turnaround after complex energy control has begun One: Safety Lead Only Four-Energy control verification procedures do not change during a turn around.

Two-permit writer and Safety lead; anytime during the turnaround after complex energy control has begun

After a test plug or plumbers plug as been installed what needs to be attached to the plug and which direction should it point? (FHSP-006.4) Vent hose, downwind Wing nut, upwind Hex nut, near the closet flange Nearest blind, to decom

Vent hose, downwind

Which activities do general lock out/ tag out of energy isolating devices not apply to? (FHSP-004) Check all that Apply: Work on cord and plug connected electronic equipment while the equipment is unplugged by the user Minor servicing activities like pump screen cleaning, filter changes, etc. Motor replacement where the motor is less than 2 horsepower. Documented hot tap or similar work with accompanying safe work documentation.

Work on cord and plug connected electronic equipment while the equipment is unplugged by the user Minor servicing activities like pump screen cleaning, filter changes, etc. Documented hot tap or similar work with accompanying safe work documentation.

Safety glasses must be rated under the ANSI standard ______ to conform to requirements set forth by the FHR Corpus Christi Complex. (FHSP-019) Z87.1 Z93.8 E2500 S25.2

Z87.1


Conjuntos de estudio relacionados

Nevada life and health blah blah blah practice questions

View Set

Module 3: Problem Set 2 (Female Reproductive System)

View Set

Med surg exam 3 practice questions

View Set

AS 221 Instrument Pilot - Stage 1 Exam Questions

View Set

Psych chapter 9, 10, 11, 12 quizzes

View Set

Chapter 4,5,6,7 Natural Disasters

View Set