NEC 422
(12) Where the GFCI protection required for appliances is an integral part of the appliance cord, it shall be installed not more than _____ in. from the attachment plug.
12 in (422.5)(B)(4)
(14) The branch circuit rating for nonmotor-operated appliances that are continuously loaded shall have the branch-circuit rating sized not less than _____ percent of the appliance marked ampere rating, unless otherwise listed
125% (422.11)
(15) If a branch circuit supplies a single nonmotor-operated appliance, the rating of overcurrent protection shall not exceed _____ percent of the appliance rated current if the overcurrent protection rating is not marked and the appliance is rated over 13.30A.
150 (422.11)
(11) For permanently connected appliances rated over _____ VA, the branch-circuit switch or circuit breaker can serve as the disconnecting means where the switch or circuit breaker is within sight from the appliance or is capable of being locked in the open position in accordance with 110.25.
300 VA (422.31)(A)
(3)An in-sink waste disposer can be cord-and-plug-connected, but the cord shall not be less than 18 in. or more than _____ in. in length.
36 in (422.16)(B)(1)
(5) The length of the cord for a built-in dishwasher shall not be longer than _____ ft, measured from the face of the attachment plug to the plane of the rear of the appliance.
6 1/2 ' (422.16)(B)(2)(2)
(13) For cord-and-plug- (or attachment fitting-) connected appliances, a(an) _____ plug (or attachment fitting) and receptacle combination shall be permitted to serve as the disconnecting means.
Accessible (422.5)(B)
(1)Appliances such as _____ rated 150V or less to ground and 60A or less, single- or three-phase, shall be provided with Class A GFCI protection for personnel.
All of these (422.5)(A)
(4) The flexible appliance cord for a(an) _____ shall have an equipment grounding conductor and be terminated with a grounding-type attachment plug
All of these(422.16)
(8) The receptacle for a cord connected range hood is permitted to be supplied by _____.
An individual branch circuit (422.16)(B)(4)
(9) Range hoods shall be permitted to be cord-and-plug-connected with a flexible cord identified as suitable for use on range hoods in the installation instructions of the appliance manufacturer provided the range hood is part of a microwave oven assembly.
False(422.16)(B)(4)
(6) The receptacle for a trash compactor shall be located _____ occupied by the appliance
In the space or adjacent (422.16)(B)(2)(4)
(7)The receptacle for a built-in dishwasher shall be located _____ adjacent to the space occupied by the dishwasher.
In the space(422.16)(B)(2)(5)
(10) Each appliance shall have a means that _____ disconnects all ungrounded circuit conductors.
Simultaneously (422.30)
(2)The branch-circuit overcurrent device and conductors for fixed storage-type water heater having a capacity of 120 gallons or less shall be sized not smaller than 125 percent of the rating of the _____.
Water heater(422.13)