Poll Everywhere (Chapters 6 & 10)

¡Supera tus tareas y exámenes ahora con Quizwiz!

The SI unit of luminous intensity is the:

candela

One daylighting design guideline suggests that there should be sufficient workplane illuminance from a window up to a distance of ________ times the head height of the window (height of the window above the desk plane).

2.5

In general, with a sidelighting system any interior area more than ________ feet (m) from a window will need to be electrically lit.

30 (9.1)

The recommended daylight factor for difficult prolonged tasks, such as drafting, is:

4.0 - 8.0 %

Which daylighting analysis method(s) work(s) only for a rectilinear space?

CIE method and IESNA lumen method

The standard sky design condition established by the Commission Internationale d-Eclairage (CIE) for daylighting calculation is:

a completely overcast sky

The brightest area of luminance in a cloudy sky is:

at the zenith

Daylight within a space is generally most evenly distributed when:

bilateral lighting from opposite walls is used

The relationship between brightness and luminance can best be described in the following way:

both are terms used to describe light coming off of an object, however brightness is subjective and luminance is measurable

Illuminance is measured more frequently than luminance because:

design recommendations for lighting levels are typically given in terms of illuminance

Illuminance levels and illuminance categories are used to:

establish quantitative lighting system design criteria

The daylighting analysis method that produces a family of daylight factor contours within a room rather than individual daylight factors at specific points is:

graphic daylighting design method (GDDM)

In general, daylight will penetrate further into a space and have a more uniform quality if windows are placed:

high on a wall

Daylight factor (DF) is defined as the ratio of ________.

indoor illuminance to available outdoor illuminance

All of the following strategies can reduce the potential for glare, except:

locate windows to allow direct views outside

The relationship between illuminance and luminance for an opaque surface is best described as:

luminance is illuminance as modified by reflectance

Which is NOT a key goal in daylighting design?

maximize the ratio of glazing to floor area

The reflection that occurs with a smooth surface such as polished glass or a mirror is called:

specular reflection

Illuminance is best defined as:

the density of luminous energy, expressed as lumens per unit area

The externally reflected component (ERC) of the total daylight factor (DF) represents:

the light reflected from exterior obstructions excluding the ground-reflected light

A "bearing angle" of 90 degrees indicates that:

the sun plane is parallel to the vertical surface in question

Photometric readings are usually taken at the height of a "working plane" because:

this approximates the height of typical visual tasks

When a light source produces energy over the entire visible spectrum in approximately equal quantities, the light appears as:

white


Conjuntos de estudio relacionados

MKTG Chapter 6 Marketing Information

View Set

Patho 38 Disorders of Thyroid and Parathyroid and Adrenal Regulation

View Set

Ch. 3 World Geo, Ch. 2 vocab., Ch. 1 vocab, Exam rev, world geo, Test on Wed, Ch. 5, world geo exam, 11 test, world geography quizlet, Test, World Geoexam, test tomorrow, test monday, EM, EA test

View Set

EMT Chapter 33 - Obstetrics and Neonatal Care

View Set

Government unit 4: The Executive Branch

View Set