quarter final
Connection by means of wire binding screws, studs, and nuts having upturned lugs or the equivalent shall be permitted for ___ awg or smaller conductors
10
In other than dwelling units in addition to requirements for field or factory marking of equipment to warn qualified persons of potential electric arc flash hazards, a permanent label shall be field or factory applied to service equipment rated ___ or more
1200 amps
where equipment operating at 1000 volts nominal or less to ground and likely to require examination adjustment servicing or maintenance while energized is required by installation instructions or function to be located in a space with limited access and where equipment is installed above a lay in ceiling there shall be an opening no smaller than
22 x 22
a minimum working space depth of ___ ft to live parts of equipment operating at 277 volts to ground is required where there are exposed live parts on one side and no live or grounded parts on the other side.
3
the minimum working space on a circuit for equipment operating at 120 volts to ground with exposed live parts on one side and no live parts on the other side of the working space is ___ feet
3
The required working space for access to live parts of equipment operating at 300 volts to ground where there are exposed live parts on one side and grounded parts on the other side is ___ ft
3.5
the minimum height of dedicated equipment space for motor control centers installed indoors is ___ ft above the enclosure or to the structural ceiling whichever is lower
6
for equipment rated 1200 amps or more and over 6 feet wide that contains overcurrent devices switching devices or control devices there shall be on entrance to and egress from the required working space not less than 24 in wide and ___ ft high at each end of the working space.
6.5
Conductor ampacity shall be determined using the ___ column of table 310.15(b)(16) for circuits rated 100a or less or marked for 14 AWG through 1 AWG conductors
60 degrees
a class a gfci protection device is designed to trip when the current to ground is ___ or higher
6MA
Conductors shall have their ampacity determined using the column of table 310.15(B)(16) for circuits rated over 100 amps or marked for conductors larger than 1 AWG unless the equipment terminals are listed for use with higher temperature rated conductors
75 degrees
nonmandatory informative annexes contained in the back of the NEC book are
A and B
In the NEC the words ___ indicate a mandatory requirement
A or B
Explanatory material such as references to other standards references to related sections of the NEC, or information related to a NEC rule, are included in the form of informational notes
False
The NEC covers underground mine installations and self propelled mobile surface mining machinery and its attendant electrical trailing cable
False
installations shall comply with the material located in the NEC annexes because they are part of the requirements of the code
False
By special permission, the authority having jurisdiction may waive specific requirements in this NEC where it is assured that equivalent objectives can be achieved by establishing and maintaining effective safety.
True
Compliance with either the SI or the inch-pound unit of measurement system shall be permitted
True
Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling
True
Some cleaning and lubricating compounds can cause severe deterioration of many plastic materials used for insulating and structural applications in equipment
True
Utilities may be subject to compliance with codes and standards covering their regulated activities as adopted under governmental law or regulation
True
Utilities may include entities that are designated or recognized by governmental law or regulation by public service/utility commissions
True
Access and ___ shall be provided and maintained about all electrical equipment to permit ready and safe operation and maintenance of such equipment
Working space
working space distamces for enclosed live parts shall be measured from the ___ of equipment or apparatus, if the live parts are enclosed
a or b
Capable of being removed or exposed without damaging structure or finish or not permanently closed in by the structure or finish of the building is known as
accessible
The NEC contains provisions considered necessary for safety which will not necessarily result in
all of these
The authority having jurisdiction has the responsibility for
all of these
Wooden plugs driven into holes in ___ or similar materials shall not be used for securing electrical equipment
all of these
The temperature rating associated with the ampacity of a ___ shall be selected and coordinated so as not to exceed the lowest temperature rating of any connected termination, conductor, or device
conductor
a ___ location is protected from weather and not subject to saturation with water or other liquids
damp
the dedicated space above a panelboard extends to a dropped or suspended ceiling which is considered a structural ceiling
false
The Nec is
for the practical safeguarding of persons and property
a conductor used to connect the system grounded conductor of the equipment to a grounding electrode or to a point on the grounding electrode system is called the ___ conductor
grounding electrode
Connectors and terminals for conductors more finely stranded than class b and class c, as shown in table 10 of chapter 9 shall be ___ for the specific conductor class or classes
identified
illumination shall be provided for all working spaces about service equipment switchboards switchgear panelboards or motor control centers
installed indoors
A circuit breaker is a device designed to ___ the circuit automatically on a predetermined overcurrent without damage to itself when properly applied within its rating
open
a___ is a point on the wiring system at which current is taken to supply utilization equipment
outlet
NFPA 70E standard for electrical safety in the workplace provides guidance such as determining severity of potential exposure, planning, safe work practices arc flash labeling and selecting ___
personal protective equipment
a contact device installed at an outlet for the connection of an attachment plug, or for the direct connection of electrical utilization equipment designed to mate with the corresponding contact device is known as a ___
receptacle
Each disconnecting means shall be legibly marked to indicate its purpose unless located and arranged so
the purpose is evident
In many circumstances the authority having jurisdiction can be a property owner or his/her designated agent
true
chapters 5,6,7 apply to special equipment, or other special conditions and may supplement or modify the requirements in chapters 1 through 7
true
A single receptacle is a single contact device with no other contact device on the same___
yoke