Chapter 1/2

Pataasin ang iyong marka sa homework at exams ngayon gamit ang Quizwiz!

Where noncombustible surface material is used on walls or ceilings, outlet boxes must be mounted so that they will be set back not more than ____ from the face of the surface material.

1/4 in (6mm)

For both metallic and nonmetallic electric outlet boxes, the maximum gap between the box and the wall material is ____ in.

1/8 in

Four or fewer luminaire conductors, smaller than ____ AWG, and/or small equipment grounding conductors that originate in the luminaire and terminate in the box, need not be counted when calculating box fill.

14

An arc flash can produce temperatures of ____°F.

35,000

On an architectural plan, a circle with the letters "PS" next to it represents a ____ lighting outlet.

Ceiling mounted lampholder with pull switch

It is the ____ that is the harmful component of an electrical circuit.

Current

The NEC requires that a(n) ____ be installed at each conductor splice connection point.

box or conduit body

If a box is not flush with the finished surface (as a result of improper installation) or if paneling, drywall, tile, or a mirror is added, then install a box extender, sometimes referred to as a "goof ____."

ring

The typical height for switches is 46 in., although some homeowners will want wall switches mounted 30-36 in. so as to be easy for children to reach. T or F?

true

One of the most far-reaching NEC rules is 110.3(B), which states that equipment that is ____ shall be installed and used in accordance with any instructions included in the listing or labeling.

Listed/Labeled or both

According to ____, unused knockouts and other openings in electrical boxes and cabinets are required to be closed.

NEC 110.12 A

For on-the-job safety, ____ puts the burden of responsibility on the employer and can impose large fines for noncompliance with its safety rules.

OSHA

Electrical wall boxes should not be mounted back-to-back in walls because ____.

Sound, fire,

In order that the connections inside an outlet box remain accessible, the NEC requires that a surface extension from an outlet box cover be made using ____.

a flexible conduit only

The screw size for typical outlet boxes is No. 8-32. The larger number, 32, refers to the ____.

a. "pitch" of the thread & number of threads per inch

A ___ is a unit of an electrical system, other than a conductor, that carries or controls electric energy as its principle function.

device

Most house wiring is done using metallic boxes, along with sheathed cable Type TM. T or F?

false


Kaugnay na mga set ng pag-aaral

Life Policy Provisions, Riders and Options

View Set

Week 3 go/ come / go back home ・return from Monday to Sunday

View Set

Anatomy 2 Packet 5 The pectoral Girdle & Upper Extremities

View Set

Unit 1: Preliminary Work with Taxpayer Data

View Set

Nclex Style: Nursing Fundamentals - Fluids and Electrolytes

View Set

TOPIC 5: THE MYTHS OF CREATIVITY & INNOVATION

View Set

Properties of Ionic and Covalent Compounds .

View Set