Code Enforcement Building Inspector 8
independently Pg 761
Ceiling suspended paddle fans shall be supported _______ of an outlet box.
energy This chapter is extracted from the 2018 of the International Energy Conversation Code. Pg 459
Chapter 11 regulates the ______ efficiency for the design and construction of buildings regulated by this code.
12 Pg 766
Cords that supply swimming pool equipment shall have a copper equipment grounding conductor not smaller than No. ________ AWG.
8 Transition ducts shall not be concealed within construction . Pg 611
Domestic clothes dryer transition ducts shall be metal and limited to a single length not exceed _______ feet.
3 Pg 760
Except for Type IC luminaries, thermal insultation shall not be installed above a recessed luminaire or within ______ inches of the recessed luminaire's enclosure.
18 48 Pg 761
Flexible cords for kitchen range hoods shall be ______ inches minimum and _______ inches maximum length.
12 12 pg 546
For gas appliance installations using the 2 permanent openings method for outdoor combustion air, one opening shall be within ______ inches of the top and one within _______ inches of the bottom of the space.
2.25 Pg 746
In calculating box fill, each NO. 12 AWG conductor shall require _______ cubic inches of free space within the box.
True Read the 2 exceptions in this section Review tables E3904.6.1 through E3904.6 (10) Pg 732
Nonmetallic boxes shall be used only with cabled wiring methods with entirely nonmetallic sheaths, flexible cords and nonmetallic raceways.
grounding Pg 757
Receptacles installed on 15 and 20- ampere rated branch circuits shall be of _______ type.
thermal know the 2 exceptions in this section Pg 758
Recessed incandescent fixtures shall have ________ protection
6 7 See exception. Also applies to circuit breakers and switches Pg 755
Switches for devices and luminaires shall not be more than _______ feet _______ inches above the floor or working platform when the switch is in its highest position.
earth Pg 751
The ______ shall not be considered as an effective ground fault current path.
6 Except where the lower 6 inch portion of the floor furnace is sealed by the manufacturer to prevent entrance of water, the minimum clearance shall be reduced to not less than 2 inches. pg 610
The lowest portion of gas floor furnace shall have not leas than a ________ inch clearance from grade level.
6 Pg 731
There shall be a wall switch at each floor to control stairway lighting where the stairway has _______ or more risers.
warning ribbon Placed in the trench at least 12 inches above the underground installation Pg 723
Underground service laterals that are not encased in concrete and that are buried 18 inches or more below grade shall have their location identified by a ___________ _____________.
smaller Pg 600
Vent connectors for draft hood equipped appliances shall not be _______ than the draft hood outlet diameter.
4 inches pg 610
What size diameter is required for fuel gas fired domestic clothes dryer exhaust ducts.
6 Pg 760
A luminaire that weights more than ______ pounds or exceeds 16 inches in any dimension shall not be supported by the screw shell of a lampholder.
12 Pg 546
A type B-W gas vent shall terminate at least _______ feet in vertical height above the bottom of a wall furnace.
36 The receptacle shall be located not more than 12 inches below the top of the basin or basin countertop. Pg 729
At least one receptacle outlet in bathrooms is required to be within ______ inches of the outside edge of each lavatory basin.