LAP 2 Panel View Plus 6 Application Editing 1
A dynamic object's _____________ tab contains information about the objects size, position, name, and visibility.
common
Object size is monitored and edited from the _______________ tab of the object properties dialog.
common
The Display List Selector object ________ ______ (does/does not) include a scrolling device.
does not
A _______________ text object contains a variable such as the time data, or a numeric value read from a PLC.
dynamic
Input objects are ______________ screen objects that allow an operator to manually input information to a process start, stop or modify operation.
dynamic
Data server tags reside in memory ________________ the PanelView Plus 6 application.
outside
Communication configuration defines ____________ from the application to tags.
paths
________________ Display buttons are used to navigate between screens.
GoTo
Communications are configured from the _________ _______________ editor.
RSLinx Enterprise
The New Display dialog is used to create and ___________________ application displays within a Studio-ME application.
configure
A _________________ is required for each tag with which a dynamic object exchanges data.
connection
Data server tags are configured as a ________________ to a PLC tag.
connection
New PanelView Plus 6 application displays can be added to existing applications or _____________ when the application is developed by the user.
created
Dynamic objects exchange data via tags with an external device such as a PLC through a __________ server.
data
The ______________ (local) path defines the tag from the Studio-ME software viewpoint.
design
Output objects _______________ information on the PanelView Plus 6 display to tell the operator about the status of the machine or process.
display
To operate a PanelView Plus 6 terminal the operator ___________ with screens and screen objects in a PanelView Plus 6 application.
interacts
Text objects are used to provide information to the user or to ____________ other display objects.
label
HMI tags reside ______________ in the PanelView Plus 6 application memory.
locally
A ____________________ pushbutton changes state when pressed and returns to original state when released.
momentary
________________ indicators receive data that represents one or more conditions of a machine or process.
multistate
The ________________ (target) path defines the tag from the PanelView Plus 6 terminal viewpoint.
runtime
HMI tags can _____________ data or offset the value a preset amount.
scale
The communications paths are stored in a _______________ and downloaded to the PanelView Plus 6 terminal.
shortcut
The Display List Selector displays are edited from the ____________ tab of the object properties dialog.
states
Display List Selector objects are ___________ objects used to navigate the displays on PanelView Plus 6 terminals.
static
_____________ objects appear on the display but do not interact with a PLC's tags.
static
PanelView Plus 6 terminals do not have a power ________________.
switch
Dynamic objects are linked to a PLC and exchange data with _______________.
tags
Pushbutton objects are used to represent the _______________ pushbuttons used on control panels.
traditional
The Multistate Indicator can be triggered either by the ______________ in its tag or by the LSB (least significant bit) that is set.
value