TCM chapter 11

Pataasin ang iyong marka sa homework at exams ngayon gamit ang Quizwiz!

Which of the following is not an acceptable means of making a steel column fire resistant Wrap the column with layers of drywall. Apply an intumescent mastic/paint. Encase the column in concrete. All of the above are acceptable means of making a steel column fire resistant.

All of the above are acceptable means of making a steel column fire resistant.

Shear studs are often welded to the top of a steel beam (see the accompanying sketch). These studs serve to: strengthen the beam's connection to an adjoining beam or girder. ensure a proper moment connection to an adjoining beam or girder. bond the beam to the concrete and cause the beam and concrete to act as a single structural unit. anchor the metal decking to the beam. none of the above.

bond the beam to the concrete and cause the beam and concrete to act as a single structural unit.

Steel production does notinclude: coking of coal. reheating in a breakdown mill. continuous casting of molten steel into W-shapes. electric furnace melting. disposal of slag.

continuous casting of molten steel into W-shapes.

Structural steel: contains roughly 2 percent carbon. is made of carbon with iron as alloy. contains nickel and chromium as alloys. is largely made from scrap automobiles. is exactly what used to be called wrought iron.

is largely made from scrap automobiles.

The accompanying sketch depicts which type of connection? Shear Moment A toe-plate connection A splined connection A joist-girder connection

moment

Open-webbed steel joists are usually used in a commercial steel-framed building to support: loads above relatively wide openings (e.g., overhead doors). stairways. roof decks. joist girders. elevator shafts.

roof decks.

Weathering and stainless steels are examples of: steel alloys. heat-treated steel. wrought iron. structural steel. cast iron.

steel alloys.

The most important aspect of a high-strength bolt connection is: heating of the bolts. tensioning of the bolts. adding nuts and washers. using A307 bolts. all of the above.

tensioning of the bolts.

You would be most likely to find leveling nuts near which item? A coped beam-to-beam connection An arc-welding electrode A column base plate Exterior X-bracing on a steel frame A beam-to-column moment connection

A column base plate

Which of the following is not an acceptable means of making a steel column fire resistant? Wrap the column with layers of drywall. Apply an intumescent mastic/paint. Encase the column in concrete. All of the above are acceptable means of making a steel column fire resistant.

All of the above are acceptable means of making a steel column fire resistant.

Which of the following terms is not associated with achieving longer spans in steel? joist girder Backup bar Castellated beam Rigid frame members Plate girder

Backup bar

Which of the following has the principal function of providing lateral stability to a steel frame? Shear connections Diagonal bracing Anchor bolts High-strength bolts All of the above

Diagonal bracing

Which of these steel framing features provides earthquake safety? Eccentrically braced frames Braced frames Composite flooring Wide-flange beams Slip-critical connections

Eccentrically braced frames

Composite steel decking reinforces the concrete slab in which direction? Parallel to the beams Parallel to the girders Perpendicular to beams and girders Only at the edges Composite decking is used only for roofs.

Perpendicular to beams and girders

Which of these is not an example of a cold-formed steel product? Light-gauge C-channel Steel deck Steel tubing Steel angle Concrete prestressing strands

Steel angle

Which of the following is primarily responsible for preparing structural steel shop drawings, which show details of connections, exact spacing of bolt holes, anchor bolt sizes and locations, and so on, and for the site steel components that are ready to be assembled without further processing? Architect/engineer General contractor Steel fabricator Steel erector Steel manufacturer (the mill)

Steel fabricator

On a drawing (blueprint), a building element is referred to as "W10 x 33." This element could be a: footing. building separation joint. beam. mullion in a glass and aluminum curtain wall. two-way slab

beam.

Shear panels or shear walls are sometimes used in steel-framed buildings. Which component of wood light frame construction serves the same function as a shear panel/wall? Floor joist Exterior wall stud Rafter Prefabricated roof truss Wall sheathing

Wall sheathing