Chapter 10 - Veterinary Center - Electrical, Mechanical, and Plumbing

Réussis tes devoirs et examens dès maintenant avec Quizwiz!

circle

A ___ on the panel GP-1 circuit indicates that it has a CB lock.

6

A ___" diameter service line is provided for fire protection throughout the building.

True

A battery standby exit sign, indicated as fixture type F7 or F33 on the prints, is an exit sign that uses a battery as a back-up power source if the building experiences a power outage.

100

A(n) ____________________ gal. hot water tank provides hot water service throughout the building.

battery emergency light

A(n) ____________________ is a battery-powered light that automatically turns on if a building experiences a power outage.

False

Black lines on Sheets M-1 and M-2 show a reflected ceiling plan that provides information about the ceiling grid layout and placement of electrical light fixtures.

150

Cat Boarding 207 has one ____________________ CFM ceiling exhaust fan that is described in the exhaust fan schedule.

number of poles

Each circuit breaker (CB) is described in terms of the trip amperes per CB and the ___.

60

Each parking lot light is supported by a 24" diameter concrete pier that must be a minimum of ____________________" below the parking lot surface.

hose bibbs

Indoor Yard/Boarding 151 has two sets of ____________________ installed in the southwest and northeast corners.

True

On Sheet P-1, cold water piping is indicated by a broken line with one dash, while hot water piping is indicated by a broken line with two dashes.

1000

One MBH is equal to ____________________ Btu per hour.

1

One volt ampere is equal to ___ watt(s).

False

SEER is the amount of cooling produced by a system for all the energy it consumes.

True

Sheet M-1 indicates that the exhaust fans connect to a 10" diameter vertical duct above Room 111 and another 10" diameter vertical duct above Room 116.

M-2

Sheet ____________________ provides information about the HVAC installation for the second floor zone.

True

The 2001 City of Chicago Electrical Code is the governing code for this work as shown on the title sheet of the prints, so all receptacle locations and spacing must be in accordance with this code.

False

The No. 8 wire in the perimeter lighting circuit is for the ground wire (equipment grounding conductor).

minimum circuit amps

The ____________________ is the highest amount of steady-state electrical current that an RTU should see when operating correctly.

electrical lighting

The floor plan and gridlines on the second floor plan appear as gray shaded lines, and the ____________________ is shown as black lines.

True

The mounting method, voltage, number of phases, and wire are shown at the top left side of an electrical panel chart.

True

The two isolation rooms have similar power configurations, each having an exhaust fan controlled by a wall switch near the door and one ground-fault-protected outlet.

seven

There are ___ heating/cooling zones in the veterinary center.

False

Waterproof audible/visual emergency lights are installed in an east/west direction in Cage 141 and powered by circuit 9.

Total external static pressure (ESP)

____________________ is generally measured at the point where airflow enters the equipment and where the airflow exits the equipment.