Chapter 2 Midterm
The industry standard height for a rack in rack units is 42U. (T/F)
True
A 66 block is more suitable for data connections than the older 110 block. (T/F)
False
When planning horizontal cabling, what is the maximum allowable distance that can be used?
100 meters
Equipment data racks most commonly are a standard width of what measurement?
19 inches
What statement accurately describes what a cable bend radius determines?
A cable bend radius is the radius of the maximum arc into which you can loop the cable without impairing data.
When creating network diagrams, what icon description typically represents a network router?
An icon that has a hockey-puck shape with two arrows pointing inward and two arrows pointing outward.
When creating network diagrams, what icon description typically represents a network switch?
An icon that is rectangular, which contains four arrows pointing in opposite directions.
In a rack setup, a device called a KVM allows multiple consoles to connect to a single device on the rack. (T/F)
FALSE
Cable that is coated with flame-resistant polyvinyl chloride (PVC) is acceptable for use in plenum areas. (T/F)
False
F5 Networks set the standard for the diagram symbols used to represent routers, switches, firewalls, and other devices. (T/F)
False
Where is a demarc located in relation to the structured cabling of an enterprise environment?
In the Main Distribution Frame (MDF)
During termination of twisted pair cabling, what should be done to ensure minimal cross talk is introduced?
No more than 1 inch of the cable should be exposed.
What is NOT a TIA/EIA recognized cabling type that can be used for horizontal cabling?
RG-6 Coaxial
What does backbone cabling consist of?
The cables or wireless links that provide interconnection between the entrance facility and MDF, and between the MDF and IDFs.
A master service agreement (MSA) is a contract that defines the terms of future contracts between parties, such as payment terms or arbitration arrangements. (T/F)
True
Each type of cable has a prescribed bend radius, which is the radius of the maximum arc into which you can loop a cable without impairing data transmission. (T/F)
True
Fiber-optic cable comes in two types: single-mode fiber (SMF) or multimode fiber (MMF) (T/F)
True
The TIA/EIA standard for wall jacks in a work area require that at least one outlet be provided for data and one for voice. (T/F)
True
The process of designing, implementing, and maintaining an entire network is called the system life cycle(T/F)
True
. A dedicated telephone switch or virtual switching device that connects and manages calls within a private organization, and manages call connections that exit the network through a VoIP gateway, is known by what term?
VoIP PBX (private branch exchange)
In a voice over IP setup (VoIP), what kind of device converts signals from a campus's analog phone equipment into IP data that can travel over a phone company's analog telephone lines?
VoIP gateway
What type of documentation tool is a website that can be edited by users, allowing them to add files and photos and links between pages?
Wiki
What is the name of the GUI front end that is available for the Nmap utility?
Zenmap
What type of diagram is a graphical representation of a network's wired infrastructure?
wiring schematic