Chapter 21: Principles and Techniques of Instrument Processing and Sterilization
Three forms of sterilization monitoring:
1. Physical 2. Chemical 3. Biological
At a temperature of 160º C (320º F), dry heat sterilization requires ___ minutes.
120
Steam temperatures in sterilizing cycles are
133.88º C (273º F) for 15 minutes and 121.11º C (250º F) for 30 minutes.
When sterilizing instruments in the autoclave, the timing is __ minutes after the controls show the pressure at 15 psi and the temperature at 121º C (249.8º F).
15
___ are vials or strips, also known as spore tests, that contain harmless bacterial spores and are used to determine whether a sterilizer is working.
Biologic indicators
What verifies sterilization by confirming that all spore-forming microorganisms have been destroyed?
Biologic monitor
____ means that it is assumed the contents of a package will remain sterile indefinitely unless the packaging is compromised.
Event-related packaging
T/F - A holding solution is used following an ultrasonic bath prior to bagging the instruments for sterilization.
False
T/F - Chemical sterilants are an excellent method of sterilization.
False
T/F - Hand scrubbing is an effective means of cleaning an instrument and recommended by OSHA.
False
T/F - multi-parameter indicators ensure that an item is sterile.
False
___ are instruments that come into contact with intact skin only.
Noncritical instruments
___ is OSHA's newer term for material data sheets.
Safety Data Sheets
Seven steps involved in processing dental instrument.
Transport, cleaning, packaging, sterilization, storage, delivery, quality
T/F - The ultrasonic solution should be cleaned frequently, at a minimum of once a day and more frequently if it becomes cloudy.
True
___ is the length of time that a germicidal solution is effective after it ahs been prepared for use.
Use-life
What is considered a noncritical instrument?
X-ray head
Examples of semicritical items include
amalgam condensers
An ultrasonic cleaner should be labeled with a
biohazard and chemical warning label
The ___ verifies sterilization by confirming that all spore-forming microorganism have been destroyed.
biologic monitoring
another term for spore testing is
biologic monitoring
The ___ is a piece of equipment that is used for sterilizing by means of hot formaldehyde vapors under pressure.
chemical vapor sterilizer
In the ___ of the sterilization center, sterilized instruments, fresh disposable supplies, and prepared trays are stored.
clean area
When returning soiled instruments to the sterilization center, the tray is placed in the __________ area.
contaminated
The ___ of the sterilization center is where contaminated items are brought for precleaning.
contaminated area
An instrument used to penetrate soft tissue or bone is identified as a?
critical instrument
the instrument classifications used to determine the method of sterilization and disinfection are
critical, semicritical, and noncritical
Before instruments are wrapped for dry heat sterilization, they must be clean and
dry
A piece of equipment used for sterilization by means of heated air is the ___.
dry heat sterilizer
A(n) ___ is a resistant, dormant structure that is formed inside of some bacteria and can withstand adverse conditions.
endospore
how do you prepare a high spped handpiece for sterilization
flush water through it
what type of personal protective equipment is necessary when one is processing instruments
google type eyewear
The least desirable method of precleaning instruments is
hand scrubbing
which method of precleaning instruments is least desirable
hand scrubbing
what methods of precleaning instruments are used
hand scrubbing, ultrasonic cleaning, and with a thermal washer and disinfector
what causes sterilization failures
improper contact of sterilizing agent, improper temperature, and overloading of the sterilizer
what is a primary disadvantage if flash sterilization
inability to wrap items
what is a major advantage of chemical vapor sterilization
instruments will not rust
rusting of instruments can be prevented by the use of what
lubrication
instruments should be packaged for sterilization to
maintain sterility
A ___ is an indicator that reacts to time, temperature and presence of steam.
multiparameter indicator
where do you place a process indicator
outside the package
what are forms of sterilization monitoring
physical, chemical, and biological
Instruments that come in contact with oral tissues but do not penetrate soft tissue or bone are identified as?
semicritical instruments
the basic rule of the workflow pattern in an instrument processing area is
single loop
Tapes, strips, and tabs with heat-sensitive chemicals that change color when exposed to a certain temperature are examples of a?
single-parameter indicator
the ultrasonic cleaner works by what
sound waves
what is an example of dry heat sterilization
static air
what type of heat sterilization is appropriate for high speed handpieces
steam and chemical vapor
what are commonly used forms of heat sterilization
steam, chemical vapor, and dry heat
kitchen dishwashers cannot be used to precelan instruments because are are not approved by what
the FDA
if instruments cannot be processed immediately, what should be done with them
they should be placed in a holding soltuion
what is a reason why pins, staples, and paper clips are not used on instrument packaging
they will cause holes in the packaging
The ___ is a device that loosens and removes debris with the use of sound waves traveling through a liquid.
ultrasonic cleaner
what is the best way to determine whether sterilization has occured
use biologic monitoring
how do you rinse instruments that have been processed in a liquid chemical sterilant
with sterile water