CT Image Quality
8
A CT tube anode angle of ______ degrees would result in the smallest effective focal spot size.
Multislice
Cone-beam artifacts only appear in ______ scanners. Third generation Second generation First generation Multislice
Uniformity
Cupping artifacts are most closely related to which image quality? Uniformity Linearity Temporal resolution Contrast resolution
Streak
Edge gradient artifacts appear as a: Streak White circles Ring Band of noise across the image
Motion
Ghosting refers to _____ artifacts. Cupping Static Ring Motion
Scanning with thinner slices
How can partial volume averaging be reduced? Scanning with thinner slices Scanning with thicker slices All of these Using a half-scan algorithm
Increasing slice thickness
Image noise can be reduced by: Decreasing mAs Decreasing pixel size Increasing slice thickness All of these
0.5
Modern CT scanners are able to differentiate tissue with density differences of less than ____%
Cone-beam
Modern multislice CT scanners use _____ geometry. Pencil-thin beam Fan-beam Parallel-beam Cone-beam
Similar tissue types share the same voxel
Partial volume averaging occurs when: Detector elements fail Metal objects are present within the patient of the patient's clothing Similar tissue types share the same voxel Cardiac studies are performed
Third generation
Ring artifacts only appear in ______ scanners. First generation Third generation Multislice Second generation
Thin slice thicknesses, small detector sizes
Spatial resolution can be improved by using (may select more than one): Thin slice thicknesses Small detector sizes A matrix with large pixel sizes None of these
Temporal resolution
The half-scan algorithm technique is used to improve: Linearity Temporal resolution Spatial resolution Uniformity
Band of increased noise across the image
Tube arcing appears as a: Ring artifact Cone-beam artifact Streak artifact Band of increased noise across the image
Outside the x-ray tube, inside the x-ray tube
Tube arcing occurs (may select more than one): Outside the x-ray tube All of these Inside the x-ray tube Because of fluctuations in line voltage
Decreased contrast resolution
What is the effect of increased image noise? Decreased contrast resolution Improved image quality None of these Increased contrast resolution
Assignment of CT numbers to known linear attenuation coefficients
What is the linearity phantom used to test? Assignment of CT numbers to known linear attenuation coefficients Temporal resolution Contrast resolution Spatial resolution
Standard deviation of the CT number in water, CT number calibration
Which of the following QC tests should be done daily (may select more than one)? Standard deviation of the CT number in water CT number calibration CT couch indexing None of these
Scintillation
Which of the following detector types produces higher quality images? Gas None of these Scintillation Linear
Smaller pixel size
Which of the following factors decreases contrast resolution: Higher mAs Smaller pixel size Smaller field of view Smaller matrix size
Scanning with thinner slices
Which of the following techniques reduces edge gradient artifacts? Using detectors with large apertures Scanning with thicker slices Scanning with thinner slices Decreasing data sampling rates
Retrospective gating
Which of the following techniques would be used for a patient who has trouble holding his or her breath or has an irregular heart beat? Half-scan algorithm Smoothing Prospective gating Retrospective gating
CT table backlash
Which of the following tests determines the ability of the patient table to return to its original position after the scan? CT table indexing CT table backlash Localization device accuracy Slice width
CT number flatness
Which of the following tests determines the uniformity of CT numbers without the image? CT number flatness High-contrast resolution Low-contrast, standard deviation of CT numbers in water
Localization device accuracy
Which of the following tests uses a solid plastic phantom with two holes drilled into it at 90 degrees angles to form an "X"? Localization device accuracy Low-contrast resolution CT numbers calibration High-contrast resolution
128-slice, 64-slice
Which of the following types of CT scanners are capable of effectively imaging a beating heart? None of these 16-slice 128-slice 64-slice
Cone Beam
Which of the following types of beam geometry results in increased scatter? Parallel beam Fan beam Pencil beam Cone beam