In regard to outside branch circuits of overhead spans of open individual conductors for 1000 volts or less up to 50 feet in​ length, the NEC Superscript ​® mandates the conductors to be NOT less than​ _____ copper in size.

10 AWG

In order to qualify as an assembly​ occupancy, a structure must be designed to hold at least​ _____.

100 people

On a floating​ pier, electrical connections within boxes that are not rated for submersion must be located at least​ _____ inches above the deck.

12

Conductors that supply footlights must have a minimum insulation rating of ​_____°C.

125

Individual partitions or grouped partitions cannot contain more than​ _____ receptacle outlets rated​ 15A, 125V.

13

For portable structures such as tents at circuses and similar​ areas, what is the clearance required in any direction from overhead conductors operating at 600V or​ less?

15 feet​ (4.5 m)

Underwater luminaires can be supplied with power not to exceed​ _____ volts between circuit conductors.

150

If a flexible cord or cable supplies a​ wet-niche luminaire, the cord or cable must contain an insulated copper​ equipment-grounding conductor no smaller than No.​ _____.

16 AWG

When installing border lighting for stages in​ theaters, the luminaires shall be arranged so that branch circuits will carry a load to NOT exceed​ _____.

20 amperes

The required overhead clearance to the​ water's edge of a swimming pool for insulated cables supported by a solidly​ grounded, bare messenger wire or a grounded neutral conductor in the voltage range of 0-750V to ground is​ _____.

22.5 feet​ (6.9 m)

Electrical distribution systems within boatyards and piers cannot exceed​ _____.

250V​ phase-to-phase

In a​ marina, the disconnecting means for a boat receptacle outlet must be readily accessible and NOT more than​ _____ from the receptacle.

30 inches

In most​ cases, wiring may not be installed within​ _____ feet horizontally from the inside wall of a pool.

5

For spas and hot​ tubs, wall switches must be located away from the inside walls of the tub by at least​ _____.

5 feet​ (1.5 m)

An amusement ride at a fair must have a disconnect switch within​ _____ feet of the ride operator.

6

The size of the bonding conductor for portable buildings at​ carnivals, circuses, or fairs must be accordance with NEC Table 250.122​, based on the largest overcurrent device supplying the portable​ structures, but never smaller than No. ​ _____.

6 AWG

When outlet boxes or other device boxes are installed outdoors at​ circuses, fairs, and similar​ locations, the boxes must be​ weather-proof and mounted so the bottom of the box is at least​ _____.

6 inches​ (150 mm) off the ground

All swimming pool electric water heaters shall have the heating elements subdivided into loads NOT exceeding 48 amperes and protected at NOT over​ _____.

60 amperes

In an area where temporary wiring supplies a voltage greater than​ _____ volts, a barrier must be erected to keep unauthorized persons from entering the area.

600

Holiday​ lighting, considered temporary​ wiring, must be removed within​ _____.

90 days of the date of installation

Which of the following places would not be considered an assembly​ occupancy?

A​ doctor's office

Which of the following conduit types is not acceptable to carry branch circuit conductors for a swimming pool pump installed​ outdoors?

EMT

All cables and cords used to supply power at a​ circus, fair, or similar venue must be rated for​ extra-hard usage.

False

A​ 125-volt general-purpose receptacle installed in a dirt confinement area for livestock does not need​ ground-fault protection.

False

Switches installed near a pool must always be kept at least​ 5' from the​ pool's edge.

False

Use an​ insulated, stranded copper conductor when bonding equipotential planes.

False

Which of the following is not a requirement for flexible cables used as permanent wiring on a floating​ pier?

Must be rated for hard usage

Is it acceptable to hang bare light bulbs as part of a temporary lighting​ scheme?

No

Which statement about theater lighting and wiring is correct​?

Portable switchboards must be installed within an enclosure.

Wiring for portable switchboards may be in the form of flexible cords and cables.

True

The use of electrical nonmetallic tubing and rigid nonmetallic conduit in spaces of assembly is restricted to certain areas such as club rooms if the building contains​ _____.

combustible supports

The hazard classification of a fueling area in a marina is determined by the​ _____.

construction of the fueling dock or pier

It is not necessary to install a box for splices or connections on construction sites in nonmetallic multiwire cord or cable assemblies as long as the equipment grounding​ conductor's _____.

continuity is maintained

When buried raceways pass under​ streets, roads or​ driveways, the MINIMUM cover requirements​ _____.

do not change in regard to wiring methods used

Any electrical connection on a fixed pier must be at least 12 inches​ (305 mm) above the deck of the fixed​ pier, but never below the​ _____.

electrical datum plane

Bare bulbs used with backstage lighting must be​ _____.

equipped with lamp guards

Building materials used in assembly occupancies are required to have​ a(n) _____.

fire rating

Where land areas are affected by tidal​ fluctuations, the electrical datum plane is 2 feet​ (600 mm) above the highest​ _____.

high tide for the area

Temporary wiring on a construction site must be removed​ _____ when the job is done.

immediately

A cord used to supply a landscape fountain must be​ _____.

listed for wet usage

In a manually controlled stage​ switchboard, all dimmers and switches are operated by handles that​ are_____.

mechanically linked to the control devices

Luminaires used in agricultural buildings must be designed to minimize the entry of​ _____.

moisture, corrosive particles, dust

​A(n) _____ is often used to connect portable stage switchboards to fixed lighting outlets.

patch panel

In areas subject to​ flooding, the electrical datum plane is​ _____.

​2' above the prevailing high water mark

Storable pool filter pumps that are​ cord-connected must be​ _____.

​double-insulated

Cords and cables used for border lights must be listed for​ _____.

​extra-hard usage

If two or more agricultural buildings are supplied overhead from a distribution​ point, a​ ____.

​site-isolating device must be installed

Outlet boxes installed on the outside of a concession stand at a circus must be​ _____.

​weather-proof