Electrical Capstone

Réussis tes devoirs et examens dès maintenant avec Quizwiz!

Section 430.32 of the National Electric Code States that a motor must be protected up to____% of its FLC Rating.

125

14 gauge NM-B cable has a maximum current rating of _______ amps.

15

Circuits which provide switchboards with pilot lights are required to be protected by standard overcurrent devices rated at ___ A or less

15

According to OSHA safety regulations, load carrying timber members must be a minimum of ___________ lb-f/in squared construction grade lumber.

1500

According to OSHA safety regulations, platforms must be at least _____in. wide or guardrails and personal fall arrest systems must be used..

18

When there is a break in elevation of ____________ or more and no ramp, runway, embankment or personnel hoist is available, employers must provide a stairway or ladder at all worker points of access.

19 inches

Any place there is a break in elevation of _____________, a stairway, ladder, or ramp, shall be provided.

19in

For purposes of receptacle spacing, the Code requires that an individual wall space shall be considered to be ____ or more in width.

2 feet

How many outside receptacles, accessible at grade level, are required for a single-family dwelling?

2 receptacles

12 gauge NM-B cable has a maximum current rating of _______ amps.

20

Handrails shall be capable of withstanding ______ pounds of downward force.

200

Cables and raceways installed under streets, highways, roads, driveways, and parking lots shall be buried to a minimum depth of ___ ².

24

Double-cleated ladders or two or more ladders must be provided when ladders are the onlyway to enter or exit a work area where _____ or more employees work or when a ladder servessimultaneous two-way traffic.

25

Each step or rung of a fixed ladder must be able to support a load of at least _____ poundsapplied in the middle of the step or rung.

250

On a blueprint scale of 1/8 inch = 1 foot, a 3 1/2 inch length represents ______ ft.

28

Permanent handrails are to have clearance of ________ inches between the rail and wall.

3

When portable ladders are used for access to an upper landing surface, the side rails must extend at least _____ feet above the upper landing surface.

3

Whenever service conductors are installed as open conductors, a clearance of ___ feet shall be provided from windows, doors, or similar locations.

3

Toe boards on scaffolding must be _____ inches tall, and no more than ____ inches above the surface of the floor.

3.5, .25

Handrails must be between ____________ in height.

30-37 inches

According to OSHA safety regulations, guardrails/toprail on scaffold platforms must be between ________ inches and _______ inches.

38,45

According to OSHA safety regulations, scaffolds must be able to support up to ____ times the intended load.

4

Portable Ladders must capable of supporting the following loads without failure.

4 times the maximum intended load.

An inductor is connected to a 120-V, 60-Hz supply. The current in the circuit is 2.4 A. What is the inductive reactance?

50 ohms

According to OSHA safety regulations, suspension scaffold rigging must be able to support up to ____ times the intended load.

6

The minimum amount of wire that should be left in a workbox is _______ inches.

6

Receptacles are required to be installed so that no point along the floor line in any wall space is more than ______ from an outlet in that space.

6 feet

A 240 volt, single-phase, 30 ampere-rated, electric clothes dryer will have a VA rating of ____.

7,200

A ground rod is required to be driven a MINIMUM of ____ feet into the soil.

8

Per 230.24(A), overhead service conductors shall have a minimum verticle clearance of not less than ___ feet above rooftops.

8

A ground rod must be a minimum of _____ in length.

8 feet

When extinguishing a fire involving wood framing or cardboard boxes, a ____________ fire extinguisher should be used.

Class A

When extinguishing a fire involving diesel fuel, a ____________ fire extinguisher should be used.

Class B

When extinguishing a fire involving an electrical appliance, a ____________ fire extinguisher should be used.

Class C

When extinguishing a fire involving a metal frame structure, a ____________ fire extinguisher should be used.

Class D

When extinguishing a fire involving cooking grease, a ____________ fire extinguisher should be used.

Class K

What symbol represents current?

I

What is the difference between inching and jogging?

Inching is accomplished by momentarily applying reduced voltage to the motor and jogging is accomplished by momentarily applying full voltage to the motor.

Article 90 of the National Electric Code Covers

Introduction

A receptacle is installed outdoors on the porch of a dwelling unit. The receptacle is located such that it is near the open railing of the porch, but it is at a height of 7 feet above grade level. Which of the following best describes Code requirements for installation of this receptacle?

It must be GFCI protected as it is outside

The National Electric Code is based on

NFPA

What agency requires employers to provide a workplace free of recognized hazards for its employees?

OSHA

The proper angle for setting up a ladder is to place the base a/an ________ of the working length of the ladder from the wall or vertical surface.

Quarter

Article 110 of the National Electric Code Covers

Requirements for Electrical Installations

Which of the following is true concerning the National Electrical Code?

The NEC is not a law unless it is adopted as law by a local authority.

What does a dashed line drawn between components represent?

They are mechanically connected together so that both will operate at the same time.

"Scaffolds where platforms are overlapped to create a long platform, the overlap shall occur only over supports, and shall not be less than 12 inches (30 cm) unless the platforms are nailed together or otherwise restrained to prevent movement."

True

What symbol represents voltage?

V

What is the unit of potential difference?

Volt

The symbol for capacitive reactance is

XC

Electrical outlet box installed in walls and ceilings are required to be _____.

accessible

Stairways with at least 4 risers, rising more than 30 inches are to be equipped with;

at least one handrail on each unprotected side

What are two types of thermal overload relay?

bimetal strip type and solder melting type

Fuses and ___ are OCPDs designed to automatically stop the flow of current in a circuit that has a short circuit or is overloaded.

circuit breakers

A Class A GFCI is a device that trips when the __ to ground has a value of 4mA to 6mA.

current

The flow of electrons is called _________

current

What happens to current when resistance increases?

decrease

Article 100 of the National Electric Code Covers

definitions

A GFCI

detects a difference in current between the black and white wires.

All portable and semi-portable tools must be grounded unless they are;

double insulated

Lockout Tagout devices must be

durable

A motor is a dynamo that used to change

electrical energy into mechanical energy.

According to OSHA safety regulations, platforms must be_______.

fully planked

What does the 12 in NM-B 12/3 stand for?

gauge

The neutral conductor is also referred to as the _____ conductor.

grounded

A grounding conductor is the conductor that connects electrical equipment or the grounded conductor to the ___

grounding electrode

What happens to current when voltage increases?

increases

The symbol X L stands for

inductive reactance

Overload relays can be classified as thermal or

magnetic

A person with a serious electrical injury should be moved

only if in immediate danger

The service ___ is the point of connection between the local electrical utility company and the premises wiring of the building or structure.

point

A motors _________ determines what proportion of the total electrical power is active power and what proportion is reactive power.

power factor

A GFCI

protects people from electrical shock

A(n) ___ is an enclosed channel of metal or nonmetallic materials used to contain the wires or cables of an electrical system

raceway system

The National Electric Code is based on

removed without damage to the building.

How many current sensing devices are required by the National Electrical Code to protect a three-phase motor operated on 480 volts?

three

S3 is the symbol for a

three way switch

A GFCI

trip in 1/40th of a second.

All 15 A and 20 A, 125 V receptacles installed in patient care areas of pediatric wards, rooms, or other areas shall be listed tamper-resistant or shall employ a listed tamper-resistant cover.

true

All receptacles in dwelling crawl spaces at or below grade shall be GFCI-protected.

true

All receptacles installed in dwelling bathrooms shall be GFCI-protected.

true

All receptacles which serve countertops in dwelling kitchens shall be GFCI-protected.

true

Conductors of different systems (600 V or less, AC and DC) may occupy the same raceway.

true

Conductors used for direct burial shall be identified for such use.

true

THW conductors are permitted to be installed in wet locations.

true

The neutral of an electrical system is always carrying the unbalanced current of that system.

true

Each kitchen is required to have a minimum of ____ small appliance branch circuit(s).

two

One way to protect workers from electrical shock is to

use insulated tools and/or coverings.

Ground Fault Interrupter circuits are normally used in _______

wet locations and construction sites

What wire can be used as a hot wire if marked with 3 black stripes on each end?

white

Bored holes through wood members must __________ from the edge.

1 1/4

Holes that are drilled into framing members to permit the installation of raceways or cables shall be at least ___ ² from the nearest edge of the wood member.

1 1/4

Cables or raceways in notches of framing members shall be protected from nails or screws by a steel plate at least ___ ² thick.

1/16

A metal underground water pipe may serve as a grounding electrode if it is in direct contact with the earth for at least ____ feet or more.

10

According to OSHA safety regulations, guardrails or a personal fall arrest system is required for workers on scaffolding ___________ ft. or higher.

10

An electrical circuit has a voltage of 50 V and a resistance of 5 ohms. What is the value of current?

10 A

Service loads to a one-family dwelling require a minimum service disconnect rating of ___A.

100

The minimum size electrical panel for a dwelling is

100 Amp

According to the National Electric Code, Flexible conduit needs to be supported within ____ inches from a junction box or outlet.

12

Service cable shall be secured within _____ of a weather head and meter socket.

12 inches


Ensembles d'études connexes

int quiz & Expressions quiz (C for Everyone: Programming Fundamentals - Week 2 Coursera)

View Set

Spinal exam 1 Practice Questions

View Set

Biology Unit 4 Chapter 5 - Energy and Ecosystems

View Set

Chapter 13: Supply Chain Management and Marketing Channels

View Set

Unit 1 Progress Check: MCQ Part B

View Set