LA- Armamentarium

Réussis tes devoirs et examens dès maintenant avec Quizwiz!

Which of the following needle gauges has the largest lumen diameter?

25

To maximize patient comfort and minimize tissue trauma, the needle should be changed after _______ injections on the same patient.

3 to 4

Which identifying mark is required by the ADA for all local anesthetic cartridges?

A standardized color-coded band on the plastic label

A bubble in the cartridge that is larger than 2 mm is harmlessly produced by nitrogen gas during the manufacturing process. A cartridge with a large bubble (>2 mm) can be used without complication.

Both statements are false

Harpoon disengagement may occur due to the folllowing EXCEPT?

Excessive engagement of the harpoon during set up

What type of needle is recommended to safely and effectively administer an injection where the target is far away from the insertion site?

Long, 25-gauge needle

Gauze 2×2 squares are a helpful supplement to the anesthetic armamentarium. Which of the following is NOT a function of a gauze 2×2?

Pressure anesthesia

As you are about to administer an injection, your needle tip inadvertently touches the patient's disposable bib (clean but not sterile). What should you do next?

Recap the needle with the one-hand scoop method, discard it and replace it with a new, sterilized needle. Proceed in administering the local anesthesia.

The American Dental Association has set forth criteria for the acceptance of local anesthetic syringes. Which of the following is NOT consistent with the ADA's standards?

The syringe must be disposable.

Routine maintenance of a reusable syringe includes inspection and replacement of a dull or bent harpoon

True

After arriving at the deposition site, you decide to redirect your needle to achieve effective anesthesia. Which of the following is an appropriate action?

Withdraw the needle completely, change the direction of the needle, penetrate, and readvance to the target location

Placing the local anesthetic cartridge in alcohol or sterilization solutions can cause ________.

a burning sensation during the injection, contamination of the local anesthetic solution, and corrosion of the aluminum cap (All of the choices)

The syringe designed to deliver a "virtually painless" injection of local anesthesia is the

computer-controlled anesthetic delivery device (CCLAD).

The _________ is a sharp tip attached to the internal end of the piston that embeds into the cartridge's rubber stopper.

harpoon

A needle with a ____________ is recommended for its ability to provide less deflection, greater accuracy, less needle breakage, and a more accurate aspiration.

larger gauge (25)

When breach-loading a cartridge into the syringe, the rubber stopper should _______.

load first

Pulling back on the thumb ring provides ____________ and produces an aspiration.

negative pressure

A _________ syringe is primarily used for PDL injections of single mandibular teeth where tissue resistance is pronounced

pressure

If the harpoon disengages during an aspiration, the clinician should

remove the syringe from the patient's mouth, remove the needle, and reengage the harpoon into the rubber stopper.

Patient discomfort is minimized through the use of a sharply beveled needle

true

When administering local anesthesia, the bevel of the needle should face the bone.

true


Ensembles d'études connexes

A.P. Bio Final Review --> Semester 1

View Set

Biotechnology & Society FINAL 1 m

View Set

Psychology - Psychoanalysis & Humanistic Theory

View Set

Bio Unit 4: DNA/RNA, protein synthesis, mutations

View Set

PSYC334: Interpersonal Relationships

View Set

International Management Exam #2

View Set

Unit 5-Other Investment Vehicles

View Set

ASVAB - Everything You Need To Know

View Set

The Essenials of Managing Conflic - Final

View Set