Metering devices
A yellow handle
A manual expansion valve can be identified by
Constant pressure valve
Another name for an automatic expansion valve is
The percentage of liquid to vapor cannot be determined
When a refrigerant is saturated, indicated by a pressure and temperature match on a P/T chart
The superheat rises causing the TXV to feed more refrigerant
What is the effect of an increase in the cooling load on a TXV
Increased pressure differential
A fixed-orifice metering device increases the flow of refrigerant in response to a
Converts high-pressure high temperature liquid refrigerant in to low pressure low temperature mix of vapor and liquid
A metering device is a refrigerant circuit device that
Electronically controlled expansion valve
A stepper motor changes the expansion valve opening in the
The amount of surface area bathed in boil liquid
Evaporator cooling capacity is significantly affected by
It is not capable of preventing floodback
How does an automatic expansion valve prevents liquid floodback in a system
Evaporator will be starving of refrigerant
If a capillary tube is restricted due to a sharp bend,the
A superheated refrigerant
In a DX system operating normally, the refrigerant leaving the evaporator should be
Decrease
In a comfort cooling system with a fixed metering device, as the heat load reduces, the superheat will
A system with a fairly constant load
In which of these applications would a manual expansion valve be a good choice
Refrigeration system with a defrost cycle
Maximum operating pressure expansion valve are manly used on
Has a sensing bulb filled with refrigerant or another thermostatic fluid
One distinguishing feature of the TXV is that it
Solenoid valves
Pulsing and analog expansion valves are special design based on
TD between the coil and cooled medium is lower
Superheat setting for low-refrigerant systems are typically Lower because the
Gradual decrease on suction temp and an increase in superheat
The best clue to the problem of moisture freezing at an expansion device is a
Setting the room thermostat abnormally low
The condition most likely to cause floodback when a fixed metering device is in use
Digital linear actuator
The device that converts an EEV motor rotation to a back and forth motion is known as
Downstream of, and near, the sensing bulb
The equalizer line of an externally equalized TXV is best to attached
Condenser coil capacity
The primary factor in determining the size of a fixed-orifice metering device is typically the
Feed equal amounts amounts of refrigerant to the evaporator circuits
The primary purpose of a distributor in an air conditioning system is to
A very low suction pressure
The symptoms that most likely indicated the thermostatic element of a TXV has lost its charge is
The system must be in operation
When changing the superheat setting on a TXV
An externally equalize TXV
Which of the following is best suited for a system with large pressure drops across the evaporator coil
They have no sensing bulb
Which of the following is true of capillary tubes
More sub-cooling improves the efficiency and capacity of the system
Which of the following statements about metering devices is true
The pressure drop through the valve has a significant effect on its capacity
Which of the following statements is true regarding TXV selection
Many distributors have a replaceable orifice
Which of the following statements is true regarding distributors
Clogged condenser coil will reduce or prevent surgery sub-cooling
Which of the following statements statements about metering devices are true