Misc Praxis
hearing handicap
the disadvantage imposed by a hearing impairment on a person's communicative performance in the activities of daily living
at 1000 Hz, 0 dB HL is
7 dB SPL (add to dB HL in question to get total dB SPL at that frequency)
if you look towards healthy side ...
nystagmus increases
if kid has no known ties to deaf culture and was learning to speak orally prior to going deaf, you want to use..
oral/aural communication
the annular ligament is closest to the
oval window
at 8000 Hz, 0 dB HL is
13 dB SPL
interaural differences in calorics must be
20% or greater to be significant
an 18 month old child should have a spoken vocab of
50 words
until the age of ___ months, babbling does not depend on auditory input
6
consider gestational age over chronological age when interpreting
ABR Wave 5 latencies
ABR for retrocochlear loss
Absent waveforms, IPL increased by > .25 ms, IA wave V latency difference of > .2 ms, amplitude ratio V/I is < 1
best kind of fitting for emphasizing HFs in HA
Acoustic modification should emphasize high-frequency amplification and de-emphasize low-frequency amplification. A short sound bore, a flared horn (Libby), and a wide vent is the best combination to achieve that goal.
when counseling parents of a child with hearing loss, the audiologist should..
Assume that much information will need to be repeated at a later date, since parents generally will recall very little of the material presented initially
the best acoustic signal for measuring frequency specific, absolute threshold in the sound field
FM tones
sounds below 1500 Hz rely on
ITDs
a pt who says they do better in noise than in quiet probably has..
CDHL
hearing better w a HL in noisy conditions versus quiet is a sign of
CDHL
most likely adult CI candidate
bilateral HL due to meningitis (bc they tend to be the most profound)
people with normal eustachian tube dysfunction have normal...
ECV
ABR for CDHL
EXTREMELY delayed absolute latencies, with IPL within normal limits
ototoxicity can cause
HF HL with bilateral vestibular loss, such as ataxia of gait/stance
larger/smaller number is better for AIDI
LARGER
WDRC
Low compression threshold, low compression ratio -WDRC provides gain adjustment across a wide range of input levels. It provides additional gain for low input levels with a low compression threshold and provides gradual increases in gain as input levels increase using a low compression ratio.
guidelines for acceptable noise can be found at...
OSHA
way to test rollover
Open-set, monosyllabic, phonetically balanced word lists, administered at several intensity levels -Speech understanding may be affected in a patient with a suspected retrocochlear lesion. Administering a performance-intensity function and then calculating rollover would be an appropriate step before referring the patient for more objective tests to rule out a retrocochlear lesion.
the acoustic reflex is mediated at the
SOC
used to measure noise in classrooms
Sound level meter
ABR for SNHL
Wave I is delayed. Wave V latency is delayed at "normal" presentation levels, but as intensity of stimuli increases (to overcome the SNHL), the latency of Wave 5 will be prolonged. *this leads to Wave I-V having a NORMAL IPL, despite the fact that Wave I is delayed.
what would NOT enhance the high frequency response of a HA, as measured in the ear canal?
a bore with a narrow diameter
hearing impairment
a deviation or change for the worse in either auditory structure or auditory function, usually outside the range of normal
false positive in audiometry
a response occurs in the absence of a stimulus, such as when a patient responds even though no signal has been presented.
a language stimulation program for a 6 month old should
be integrated with routine activities in the home
use of inserts over headphones for ABR testing generally changes...
absolute latencies (delay of sound traveling through the tubes)
functional gain of HA is best determined by
aided vs unaided sound field thresholds
between group design
an experiment that has two or more groups of subjects each being tested by a different testing factor simultaneously.
the _____ ligament holds the stapes to the oval window
annular
insertion loss
decrease in natural amplification when the auditory canal is closed off
hearing disability
determination of a financial award for the loss of function caused by any hearing impairment that results in significant hearing handicap.
reduced visual function that can complicated aural rehab is most common in patients with
diabetes
activity limitation
difficulty encountered when executing a task/action
participation restriction
difficulty experienced during involvement in life situations
post-active head shake test revealing left beating nystagmus indicates
dynamically uncompensated peripheral right vestibular lesion
strong motivation to wear HA is an indicator of
early positive acceptance of HA
to reduce the gain of low level sounds..
enable expansion
if they have good low frequencies through 1500..
go with a RITE open fit
intensity differences and spectral cues occur at
high frequencies
APGAR
higher score=excellent condition
HASP
include patients' self-perceptions in many areas related to core beliefs and attitudes that might impact the successful selection and fitting of amplification.
strongest correlation efficient
is the number farthest away from zero
fixed setting of the hearing-level dial of a pure-tone audiometer, what is true of the actual sound-pressure level (SPL) output of the audiometer earphone?
it is lowest at mid frequencies highest at low frequencies, increases at high frequencies
CPHI
lengthy Communication Performance, Communication Environment, Communication Strategies, and Personal Adjustment.
PHAP
lengthy assess experience with amplification in terms of speech communication in three types of listening situations and in terms of reactions to amplified environmental sounds.
HHIA
lengthy may have questions that don't refer to the pts lifestyle specifically emotional/social/situational
Test-retest reliability and split-half reliability are
measures of how consistently a test ranks a group's performance on a test
common medical conditions associated with ped balance disorders
migraine, BPVC, OM, viral infection, head trauma
continuous interleaved sampling
minimizes the channel interaction by presenting pulses to each electrode in a non overlapping sequence
if you don't account for RECD when fitting an infant, you will most likely..
overamplify them The output SPL in an infant's ear is typically higher than it is in a coupler because of the small ear canal volume in an infant's ear.
hardest for those with hearing loss to distinguish
placing
COSI
promotes focus on patient's individual needs when designing a rehab program IN A TIMELY MANNER
what type of signal is used for identification audiometry for school aged children, according to ASHA
pure tone signals
otologically normal 13 y.o boy is lying to you on audio testing. you should..
reinstruct and use ascending method
a false positive when doing audiometric testing indicates
response occurs in absence of stimulus
PL-99457
specifies that a plan be developed but does not specify the types of services to be delivered.
clients with TBIs are more likely to respond to...(during audio exam)
speech testing
chorda tympani
taste
content validity
the ability of a test to measure what it was designed to measure
disinfection
the process of eliminating or reducing harmful microorganisms from inanimate objects and surfaces ok for "non critical" items that do not touch blood/potentially infectious areas/not likely to break the skin
sterilization
the process of killing all microorganisms needed if object is contaminated with blood, mucous, or other bodily fluids *cold sterilization w chemicals
performance level rises most steeply with small increases in intensity when...
the speech sample is large and provides some context
analog hearing aids do not allow for...
the storage of different frequency responses so the client can adapt the aid to different listening situations
single subject design
the subject serves as his/her own control, rather than using another individual/group.
within-subjects design
variable is being manipulated within subjects, each subject serves as its own control
easiest for those with hearing loss to distinguish
voicing
unethical practice
when professional has inappropriate training for said procedure