Refrigeration Licences Review
In a well designed compressor the percent of lubricant circulated should not exceed
10%.
360000 B.T.U.S would be removed in a
30 ton system.
Efficient of the refrigeration cycle is affected by the operation of the condenser.
A more efficient operation of centrifugal compressor results from lower condenser pressure.
Clearance volume
Affects compressor capacity.
The cylinder unloader controls capacity
Assisting with compressor start up is another function it may have.
A refrigeration unit is measured in
B.T.U.S
High condenser temperature and low condenser water temperature will
Cause the greatest BTUs absorbed by the condenser water.
The solenoid unloaders on reciprocating compressors are
Designed to unload the clearance spaces in the cylinders.
The centrifugal compressor generates
High volume and low pressure (relative) inside.
if you were running three compressor
Highly super heated vapor describes the state of refrigerant leaving the third compressor.
Non-condensable vapors collect
In the condenser.
The condenser that uses air and water for cooling
Is the evaporative type.
If you sub-cool the refrigerant
It will enhance refrigeration effect.
Shell and coil condensers have the advantage of having
Less of a chance of developing leaks.
Oil foaming in the compressor is a result of
Liquid refrigerant in the crankcase.
If unloaders were to fail in the unloaded position
Not enough refrigerant will flow to the evaporator coil, the evaporator will then starve, causing high superheat in a system using a reciprocating compressor.
Superheated vapor flowing into reciprocating compressor protects the compressor parts against liquid intake.
One of the problems associated with superheat is that it will decrease the capacity of the compressor and the refrigeration machine.
An operator has been assigned to run a reciprocating compressor
Opening the suction valves with some form of control is the most likely achieved action of capacity control.
When a system does not have unloaders,
Other capacity control is needed.
Unloaders are used to
Reduce capacity.
At the condenser
Refrigerant enters as high pressure gas and leaves as high pressure liquid.
The ratio of actual pressure of water vapor in the atmosphere to the saturation pressure/temperature is called
Relative humidity.
Superheated vapor protects the compressor against liquid intake.
The RMO would notice frost that may develop in the suction line if the compressor was receiving liquid.
An operator has been assigned to run a centrifugal compressor
The capacity control most likely achieved is through adjustment of the impeller inlet guide pre-rotation vanes.
The dividing line between the high and low sides of the refrigeration system is
The compressor outlet and the orifice of the metering device.
If a centrifugal compressor is being used in a refrigeration system, and is effected by the condenser
The condenser may be improved by increasing the amount of sub-cooling.
Low evaporative and low condenser temperature are
The conditions that would cause the greatest heat in BTU/HR MIN absorbed by the condenser water in a refrigerating plant.
Refrigerant oil quality is measured in viscosity
The last desirable quality in the oil would be low viscosity.
In a 3 stage centrifugal chiller
The pressure increases as it reaches the final stages.
In relation to the suction pressure of a compressor,
The reading of the oil pressure gauge should read 15-30 psi higher.
Shell and tube condenser have the advantage of when removing heads for cleaning the water side of the tubes
The refrigerant connections do not have to be disrupted.
if the refrigerant is entering the sub-cooling tubes of the condenser as a gas
Then the system is short of refrigerant.
Oil in a refrigeration system reduces
Wear and friction.
If you just purchased a thermometer and need to check to see if it's working
You would touch it to a bucket of ice/ice water.
A mechanical seal is
a shaft seal that prevents vapor from leaking out of compressor.
Semi-hermetic compressors may be better to use than hermetic compressor,
because hermetic compressors are fully enclosed and cannotbe serviced on site.
In a centrifugal three stage compressor impellers are the same size,
but the pressure increases with each stage.
Tip speed is more with
each stage of a multistage centrifugal compressor.
When changing water to ice
latent heat must be remove
Any heat that boils off is
latent heat.
A pressure relief valve that is installed on a reciprocating compressor using R-12 is normally
set according to design pressure.
The state of refrigerant as it leaves the compressor is
super heated vapor and as it leaves the condenser is warm sub-cooled liquid.
Compressor motors that operate inside the refrigerant atmosphere (atmospheric) must
use materials compatible with the system refrigerants, motor must be assembled in clean atmosphere and keep dry, and or not working on in the field.