VDV: Applications and Installation (Part 3 of 3)

Réussis tes devoirs et examens dès maintenant avec Quizwiz!

Blown fiber _____.

-allows for additions to the installation to be made at a later time -an installation method in which a housing containing many smaller tubes is installed without fiber -is typically used for underground installations

Certification testers _____.

-are the only testers that can be used to certify network cabling -test instruments used to test and certify cables in a system in order to obtain a warranty from the structured cabling system OEM -can perform many of the functions of a qualification tester -can perform many of the functions of a verification tester -must be factory calibrated periodically in order to maintain the level of accuracy required for certification tests

When pulling cable, the maximum tension should not exceed _____.

25 ft-lb

The smallest conduit that can be installed on commercial or industrial projects is _____ trade size.

3/4"

In a Tier _____ data center, all the components are fully fault-tolerant, including uplinks, storage, chillers, HVAC systems, and servers.

4

The TIA recommends limiting the fill of a cable tray to _____.

50%

A typical patch panel provides the termination and patching point for _____ duplex connections.

6

The _____ standard covers the administration of a telecommunications infrastructure.

ANSI/TIA 606

A network must be active when undergoing a qualification test.

False

Containing fire, smoke, and gases provides less time for occupants to safely exit a building and firefighters to extinguish the fire.

False

Glass can conduct electricity.

False

Handwritten labels are acceptable as a final label for cable or telecommunication outlets.

False

Removing cables from their ports is required to complete a blinking diagnostic test.

False

TRs are typically larger than ERs.

False

Tip conductors terminate on the even-numbered rows, and the ring conductors terminate on the odd-numbered rows.

False

Wiremap testers are intended for use on active telephone systems, active telephone equipment, and AC circuits.

False

_____ cables are those that are routed from a telecommunications room to individual work areas (computers).

Horizontal

Open-air cable pulling involves pulling cable through _____.

I. a series of J-hooks II. a series of rings and loops

MTP connectors are _____.

I. a variation of MPO connectors II. ideal for high fiber-count data center and parallel-optical connections between servers III. used specifically for indoor cabling and device connections

A cable support system _____.

I. are normally installed by VDV technicians II. may be installed by electricians if the system requires extensive use of conduit III. must be in place before a cable can be installed

A qualification tester _____.

I. are sometimes referred to as network testers II. can be used on coaxial cable III. can be used on twisted-pair cable

The three steps for cable installation are _____.

I. cable penetration firestopping II. cable preparation III. cable pulling

Wiremap testers _____.

I. can be used with coaxial cables II. can be used with twisted-pair cables III. can identify active Ethernet ports IV. consist of two separate elements, a wire mapper and a remote unit

The two most common types of verification testers are toners and wiremap testers.

True

When terminating an F-type connector, the outer barrel of the connector should cover the braid.

True

A _____ separates a group of strands from other groups for protection and identification purposes.

buffer tube

The minimum bend radius for four-pair twisted cable should be _____ the cable diameter.

four times

The most common termination performed by a VDV technician is the termination of _____ twisted cable.

four-pair

A _____ splice uses heat to join the two strands.

fusion

A(n) _____ is a device that uses a high-voltage electrical arc between two electrodes to heat and melt the ends of glass fibers in order to join them and form a continuous strand.

fusion splicer

A(n) _____ provides a connection point at the end of a fiber-optic cable and can accommodate multiple connectors.

housing enclosure

The most common tool used for IDC terminations is a(n) _____ tool.

impact / punchdown

As a signal is "split," signal strength _____.

is lost

After fanning out wire pairs and straightening each wire, the next step in the termination process for a 110-style patch panel is to _____.

lace the wires into the 110 block according to the color code

A _____ is an end-to-end transmission path provided by a VDV cabling system.

link

When testing cables or bundles, the cable that produces the _____tone is the cable being tested.

loudest

A certification tester _____.

measures the length of a cable to determine if it complies with the associated standard

Proper cable management is _____.

more critical with fiber-optic cable than with copper cable because fiber-optic cable is more susceptible to damage

A(n) _____ pair is a fault that occurs in VDV cabling when one or both conductors of a pair are not connected.

open

A _____ is a set of devices used to route telecommunications cables from a telecommunications room or equipment room to a work area.

pathway

If a cable is run above a suspended ceiling used as an air handling space during open-air cable pulling, _____-rated cable must be used.

plenum

Raceways do not include _____.

plenum

In a fiber-optic network, _____ refers to the direction of transmission paths between the transmitters and receivers of channels.

polarity

To identify a wire pair using a toner, connect the _____ lead of the tone generator to one wire of the twisted pair.

red

When terminating four-pair twisted cable using 110 wiring blocks and C-4 connecting blocks, the first step is to _____.

route the cable to the row where it terminates

A _____ tester consists of two separate elements: a wire mapper and a remote unit.

wiremap

Tip conductors are _____for wire pairs 16 to 20.

yellow

When terminating an RJ-45 modular plug, technicians should strip approximately _____ of jacket from the cable.

2"

A through penetration _____.

-example would be a VDV cable that passes through a fire-rated floor -is a penetration that passes completely through a fire-rated element

A Tier 2 data center _____.

-has everything a Tier 1 data center has -helps to control a building's heating and cooling systems

Advantages of using a fiber-optic cable-management system includes _____.

-it provides physical protection for fiber-optic cables -the system provides a clear, well-defined path between equipment, cabinets, and racks -the system provides an easy access to the fiber-optic cables for troubleshooting, moves, additions, and changes

Per the TIA, the maximum length allowed for a conduit run is _____.

100'

A 66 block can accommodate up to _____ four-pair cables, leaving the bottom two rows unused.

12

A splice tray can typically hold up to _____ fused optical fibers.

12

Parallel optics typically use _____ fiber strands next to one another.

12

Coaxial cable consists of a(n) _____ center conductor, made of copper or copper-clad steel and surrounded by foam insulation.

18 to 22 AWG

A _____ width across the front is the standard size for a rack in the telecommunications industry.

19"

_____ is the reduction in power of any signal, light beam, or light wave, either completely or as a percentage of a reference value.

Attenuation

_____ is the ratio of signal strength to undesired signal noise in a twisted-pair cable, as measured at the far end of the cable.

Attenuation to crosstalk ratio far-end (ACR-F)

_____ fiber is an installation method in which a housing containing many smaller tubes is installed without fiber.

Blown

_____ are hardware devices used to organize the cables in a network system.

Cable racks

_____ testers can be used to certify network cabling.

Certification

A toner probe _____.

I. has an inductive probe, an amplifier, and a speaker with volume control II. is also known as an inductive amplifier III. produces an audible sound when it detects a signal from a tone generator

_____ loss is the loss or degradation of a signal in a VDV cable when a connector is inserted into another connector or associated hardware.

Insertion

_____ connectors have a free-floating ferrule.

MTP

_____ is the ratio of signal strength to undesired signal noise in a twisted-pair cable at the near end of multiple transmit pairs to an adjacent pair, as measured at the far end of the cable.

Power sum attenuation to crosstalk ratio far-end (PS ACR-F)

_____ is used for security equipment, surveillance equipment (CCTV), and older CATV installations.

RG-59

_____ is the first step when installing and terminating a copper VDV system.

Rough-in

Copper VDV cables (twisted pair and coaxial) originate in a(n) _____and are routed through various raceways and supports to work areas.

TR

A mechanical splice is adequate for most applications.

True

A terminated LC connector from one OEM will connect to an LC connector from another OEM.

True

Blinking the port of a hub or switch can help a VDV technician determine which port a cable is connected to.

True

Cable ties are not recommended for cable management as they can cause cable deformation over time.

True

Fiber-optic cables use light for signaling.

True

Firestopping is the process of sealing any penetration in a fire-rated building element in order to maintain its rating.

True

The Fiber Optic Association recommends not looking directly into the end of a fiber cable until verifying that there is no light source at the opposite end.

True

A "pass" or "fail" result of a qualification test is not based on _____.

attenuation

Ring conductor colors are _____ for the fourth pair of wires in a group of five.

brown

A _____ is the end-to-end transmission or communications path over which application-specific equipment is connected.

channel

The T568B termination pattern is more common in _____ installations.

commercial

When verifying that a twisted-pair cable and its data outlets are wired correctly using a wiremap tester, the first step is to _____.

connect the remote unit to the cable or data outlet

A telecommunication room's (TRs) primary function is to serve as a _____.

connection point between backbone and horizontal cabling

A _____ is a facility enabling the termination of network cables, as well as their interconnection with other cables or devices.

cross-connect

The most current OEM instructions are typically found on an OEM's _____.

website

Twisted-pair cable faults are caused by _____.

damage to the cable and improper terminations

A(n) _____ is a building or part of a building that is designed, built, and maintained specifically to house and connect computer servers.

data center

Qualification tests are performed to _____.

determine if a cable has sufficient bandwidth to support a particular network

A(n) _____ is a central space that serves telecommunications equipment for occupants of a building or a campus of several buildings.

equipment room (ER)

A(n) _____ pair is a fault that occurs in a VDV cable when the wire in one pair is interchanged with a wire in another pair.

split

A _____ cassette passes fiber-optic strands through in the same order as the incoming cable.

straight

A _____ is a device installed on the end of a VDV line that absorbs a signal to prevent signal leakage through an unused port.

terminator

Typically, the higher the cable category number, _____.

the higher the required cable performance level and the greater the number of certification test parameters

Standards for four-pair twisted cable specify _____.

the maximum length of a permanent link as 90 m and the maximum length of a channel as 100 m

With a shorted coaxial cable, _____.

the shield and center conductor are unintentionally connected and have electrical continuity

A _____ conductor is the first wire in a pair of wires.

tip

A _____ is a test instrument designed to identify and locate a copper conductor or cable.

toner

On large jobs, _____ set(s) of preprinted self-adhesive labels are generated by the VDV contractor.

two

Per the TIA, only _____ 90° bend(s) is/are allowed in a conduit run.

two

Originally, 66 blocks were designed to splice _____ cables.

two 25-pair

A(n) _____ tester is a test instrument designed to trace the path of conductors and confirm that conductors and data outlets are wired correctly.

verification


Ensembles d'études connexes

Retirement plans - life insurance exam

View Set

Consumer Behavior Smartbook chapter 1

View Set

Macroeconomics Review for Final Exam

View Set

Convection, Convection, Convection,

View Set

Business Strategy Chapter 8 Connect Questions

View Set

OSHA 30 HOUR QUIZ (1) Introduction to OSHA

View Set

FDR's Economic Bill of rights vocabulary

View Set