609

अब Quizwiz के साथ अपने होमवर्क और परीक्षाओं को एस करें!

ozone layer is

"Good up high , bad nearby" at ground level the ozone layer can be harmful to breathe

The EPA approved only two types of equipment what are they

1.Recover/recycle 2. Recover

Whistle blowers can get paid up to

10,000

How many ozone molecules can be destroyed by one chlorine atom?

100,000

Recovery equipment must have a filter with a minimum of

15 microns in order to remove particles

The Montreal protocol came in effect in

1987

The use of CFC in motor vehicles ended in

1994

HFC is expected to be gone by

2021 in all light duty vehicles

Failure to comply to the epa FCA act could cost you and the company up to

27,500 dollars per day

Ozone molecule consists of

3 oxygen atoms

Montreal Protocol was

A agreement between 24 nations including the United States of America

Some companies use the term drop-in meaning

A refrigerant will perform identically to CFC-12

Reclaimed refrigerant must meet the requirement of the following standard:

ARI 700

Manifold gauges allow technicians to diagnose system problems

And to charge, recover, and or recycle refrigerants.

No matter if a car is original or retrofitted the technician must

Apply a detailed label giving specific info about the alternative

Unique fittings are

Attachment points

The agency encourages do it yourselfer to do what

Bring their cars to certified technicians who can fix there air conditioners properly using the right equipment

How do you clean an refrigerant

By separating the oil and removing moisture by passing it through one or more filter dries

Ozone depletion causes

Cataracts, skin cancer, crop loss, deforestation, immune system suppression

When retrofitting your vehicle you must

Change your refrigerant oil

EPA regulations prohibit technicians from

Changing fittings back and forth ex: CFC-12 in the morning, HFC-134A in afternoon , back to CFC-12 in the evening

What element in refrigerants cause ozone depletion

Chlorine atom

CFC stands for:

Chloro - fluoro - carbon

On July 1 1992 it was illegal to vent

Class 1 and class 2 refrigerants into the atmosphere

CAA stands for

Clean Air Act

To recycle is to

Clean the refrigerant for reuse

Unique fittings help protect

Consumers by ensuring that only one type of refrigerant is being used

Step 2 of retrofitting

Cover the CFC-12 label with the new refrigerant label

The phase out CFC was completed

December 31 1995

Approved equipment must have a label that states

Design certified to meet SAE standards

No alternative refrigerant can be used as a

Drop in

June 1 1998

EPA allows recycling of refrigerant blends used in MVAC

A processed refrigerant must

Equal the level of a new product specifications as determined by chemical analysis

Step one of retrofitting

Extract the CFC-12

True or false you can mix oils

False

True or false you can use older equipment to recover uncontaminated CFC-12 and or HFC-134a

False

HFCs are potent _________ gases

Greenhouse

Since 1994 the most common refrigerant used in mvac systems are

HFC-134A

What refrigerant is ozone friendly

HFC-134A

What refrigerant is ozone friendly

HFC-134a

HFC stands for?

Hydro florine carbon

PAG's are

Hygroscopic, which means they draw water from there atmosphere when exposed

Step 5 of retrofitting

If the system includes an pressure release device the technician must install a high pressure compressor shut off switch to prevent the compressor from increasing pressure until the refrigerant is vented

Step 4 of retrofitting

If you are retrofitting a vehicle that contains R-22 you must ensure that you only use barrier hoses

The recover/recycle equipment does what

It extracts the refrigerant from the vehicle and cleans it on site

The recover equipment does what

It extracts the refrigerant into an approved container for the refrigerant to be sent off for reclamation

What happened on July 1 1992

It is illegal to vent

Section 609 of sales restrictions does what

It prohibited the sale of small small cans of ozone depleting refrigerants to anyone other than certified technicians

When was it illegal to vent class 1 and class 2 refrigerants into the atmosphere

July 1 1992

SNAP was in effect on

March 18 1994

Under the SNAP rule each new refrigerant must

Meet and comply with all epa regulations and requirements

Recycling equipment must

Meet the the UL standard

Oils can not be

Mixed

Mvac stands for

Motor vehicle air conditioner

What is topping off?

New refrigerant on top of an old refrigerant

If you are certified to handle all refrigerants do you need to be recertified

No

As of November 15 1995

No alternate refrigerants including HFCs will be vented into the atmosphere

Section 608 of the sales restrictions went in effect on

November 14 1994

What day was it illegal to vent HFCs into the atmosphere

November 15 1995

Unique fittings must be

Permanently attached to the end of the hoses that attach to mvac systems and recovery and recycling equipment

What happened in November of 1990?

President bush signed the clean air act

What is the purpose of the compressor shutoff switch

Prevent the compressor from increasing the pressure to the point where the refrigerant is vented

To reclaim is to

Process the refrigerant to a level equal to new product specifications as determined by chemical analysis

Service shops also has to make sure every person using the equipment is

Properly trained and certified

ozone layer

Protective layer in atmosphere that shields earth from UV radiation and helps maintain stable earth temperature

Which refrigerant is the most harmful to the ozone layer

R-12 CFC or CFC's

Which refrigerant is most commonly used as a replacement for R-12 in new household refrigerators

R-134a

What are the 3 R's

Recover, Recycle, Reclaim

HFCs are primarily used for

Refrigeration and air conditioning

The Montreal protocol was to

Regulate the production of chlorofluorocarbons, halons, and hydrochlorofluorocarbons

Montreal Protocol does what

Regulates the phase out production and use of CFC and hfc

What is ozone depletion?

Release of refrigerants into the atmosphere

To remove the original refrigerant you must

Remove the original CFC-12 from the system prior to charging with the new refrigerant doing this will prevent the contamination of one refrigerant with another

To recover is to

Remove the refrigerant and store it in a approved external container

The sale of any size container of CFC-12 to anyone other than a certified technician was prohibited under what

Section 608 of the sale restrictions on November 14 1994

UL first certified recovery/recycling equipment in

September 1989

Each new refrigerant must be used with a unique

Set of fittings

EPA has determined there are ___ refrigerants that are acceptable for use as CFC-12 replacements in mvac

Several

Refrigerant recovered from older equipment has to be

Shipped off for reclamation or destruction

What does SNAP stand for

Significant New Alternative Policy

SNAP stands for

Significant new alternative policy

SAE stands for

Society of Automotive Engineers

Barrier hoses are used to

Stop refrigerants from leaking or seeping through

Retrofitting is

The changing a CFC-12 vehicle to HFC-134A

Each new refrigerant must be used with a unique set of fittings to prevent

The mixing of different refrigerants

In September 1989 what happened

The ul certified the first recovery/recycling equipment

Service shops must certify to epa that

They have acquired and is properly using the approved refrigerant recovery equipment

Why is recovery of a refrigerant necessary

To prevent venting into the atmosphere Prevent stratospheric ozone depletion For adequate supplies for service after production bans

Technicians who repair or service CFC-12 and HFC-134a in mvac must be

Trained and certified by an epa-approved organization

True or false a recovered refrigerant can be returned to the mvac system if it has been recycled and or reclaimed

True

UL stands for

Underwriters Laboratory

What helps protect the consumers by ensuring that there is only one type of refrigerant used in each car

Unique fittings

Can a recycled refrigerant be returned to a mvac system

Yes

Can technicians use old equipment to recover refrigerants

Yes but only contaminated refrigerants

Step 3 of retrofitting

You must attach new fittings unique to that refrigerant

What does hygroscopic mean?

tending to absorb moisture from the air


संबंधित स्टडी सेट्स

EMT Chapter 34 Pediatric Emergencies quiz

View Set

Peds - Chapter 16: Growth and Development of the Newborn and Infant

View Set

macro chapter 14, Economic - Chapter 9: inflation, Macroeconomics Chapter 8 (add-on), Chapter 14 Money and Banking, Macro Chapter 8, Money and Banking Chapter 14

View Set

Chapter 5 - Other Pooled Investments

View Set

Modules 3 - 5: Network Security Exam

View Set