20-ft-high column shortens by 0.6 in. under a load. What is the resulting strain in the column
.0025
The total number of occupancies (excluding the divisions) as specified in the International Building Code is
10
In a building whose structural system consists of columns, beams, and floor and roof slabs, the columns are spaced at 40 ft on center in one direction and 25 ft on center in the other direction. What is the tributary area for an interior column?
1000ft2
For most building of the in the United States, the design wind speed for an average risk building is
115mph
A rectangular column measuring 12 in. x 12 in. in cross section carries a load of 18 kips. What is the stress in the column?
125psi
If a multistory building is provided throughout with automatic sprinklers, the allowable area per floor of the building may be increased by
200%
If automatic sprinklers are provided throughout the building, the buildings height may be increased by
20ft above the basic allowable height
The design wind speed for a location is the peak
3 second gust speed
The International Building Code is generally updated every
3 years
A reinforced concrete beam measures 12 in. x 24 in. in cross section. If the density of reinforced concrete is 150 lb/ft:3, the weight of the beam is.
300 lbs
If a single-story building is provided throughout with automatic sprinklers, the allowable area per floor of the building may be increased by
300%
If the total area of land under a property is 15,000 ft2 and the total covered area on all floors of the building is 60,000 ft2, the FAR for the property is
4.0
The floor live load in a residential occupancy is generally assumed to be
40 psi
The MasterFormat consists of
50 divisions
If the maximum allowable area per floor for a building is 20,000 ft2 and the maximum allowable height is 11 floors, what is the maximum 2 allowable area for the entire building?
60,000ft2
Writing and periodically updating the building code is generally done by
A specialized independent agency
Which of the following is the largest standards-writing organization?
ASTM
In the CMAR method of project delivery, the CM
Advises the owner and managers the project and works as the general contractor
When does the owner receive manufacturers' warranties from the general contractor?
At the substantial completion inspection
The design standard wind speed
Basic wind speed
The three surety bonds used in a typical construction contract are:
Bid bond, performance bond, and payment bond
In a simple three-member truss consisting of two rafters and a tie, each member is in
Both tension and compression
The person in charge of enforcing the building code is generally called a
Building official
Before commencing the construction of a building, the owner must apply to the city to obtain a
Building permit
The enforcement of a building code is usually done at the level of
City in which the building is located
The material in an arch is primarily in
Compression
The bearing strength of a material is closely related to its
Compressive strength
The Masterformat has been developed by the
Construction Specifications Institute
A contract document set consists of
Construction drawings and project manual
The test specimen used for determining the compression strength of concrete in the United States is a?
Cylinder measuring 6in dia. X 12" high
The project delivery method in which only one firm is contracted for both design and construction of the building is called the
Design build method
The first step in applying the building code to a project is to
Determine the occupancies classification of the building
Which of the following loads can be estimated with greatest certainty
Dread loads
Which gives greater warning before failure?
Ductile material
The adoption of a model building code in the United States is done
Each city or each state
Low-carbon (mild) steel is
Elastic plastic material
Shop drawings are generally reviewed by the
Everyone
With respect to wind pressure a building site is classified in terms of
Exposures B,C, D
True or False - Establishing the project's economic feasibility and its overall budget is part of the design phase of the project.
False
True or false - Performance-type building code provisions inhibit the use of innovative building materials and construction systems compared with prescriptive type provisions.
False
True or false - The construction drawings of a building project are drawings that the architect uses to explain the design to the owner
False
The building code requirements for the means of egress from a building are primarily
Fire safety issues
The term FAR refers to
Floor area ratio
The construction drawings of a building project are generally in the form of:
Free hand sketches or 3-d drawings
A record document set is generally prepared by the
General contractor
In the traditional project delivery (design-bid-build) method for a building, the day-to-day supervision of the construction ,is generally the responsibility of the
General contractor
The classified two main are categories under which all building loads may be classified are
Gravity loads and live loads
In a steel column that rests on a concrete footing, the area of the bearing plate used is generally
Greater than the cross sectional area of the column
The design snow load on a roof is function of
Ground snow roof slope and wind exposure
Which of the following beam cross sections is structurally more efficient in bending?
I -Section
The project delivery method that ensures the least amount of litigation among parties contributing to the project is the
IPD method
The stirrups in a reinforced concrete beam are used to
Increase the strength of the beam in shear
On a leeward wall the wind pressure
Is almost constant with height above the ground
If during the construction of the building, the building inspector discovers a gross violation of the building code, he or she will generally
Issue a stop work order to the owner
The loads on a column are generally expressed in
LB
The loads on a beam are generally expressed in
Lb/ft
The loads on a floor are generally expressed in
Lb/ft2
Roof live load is a function of the building's occupancy.
Less than the floor live load
Which of the following occupancies has the highest floor live load
Library stack rooms
The building code requirements for the dimensions of treads and risers of a staircase are
Life safety issues
The final completion inspection of the project is generally conducted by the
Local jurisdiction
In the Master Format, Division 04 refers to:
Masonry
Which of the following is not a standard-writing organization?
NSF
The units of modulus of elasticity are
PSI, PA, KSI, GPa
The realization of a typical building project, as described in this text, may be divided into:
Pre-design, design, pre-construction, construction, post construction
A hotel building is a
Residential occupancy
The number of mild (minor to very minor) earthquakes occurring on the earth is almost
Several thousand a year
To ensure that the construction of the building is being done in accordance with the building code, the city will arrange for its inspection
Several times during construction
In relation to its compressive strength, the tensile strength of concrete
Slightly higher
Modulus of elasticity refers to how
Stiff a material is
The shop drawings are prepared by the
Sub Contractor
In a suspension bridge, which member(s) is (are) in compression?
Support pylons
According to the geologists, the earth's surface is composed of
Tectonic plates
In the case of a dispute between the building official and the owner about the interpretation of a building code provision, the matter is first resolved by
The board of appeals of the city
The construction drawings of a building project are prepared during the
The construction document stage of the project
A building code regulates
The design of a building and the construction of a building
In the traditional project delivery (design-bid-build) method, who is typically responsible for obtaining the certificate of occupancy from the local jurisdiction?
The general contractor
Who is responsible for ensuring the safety of workers on the construction site of a typical building project?
The general contractor
The International Building Code is published by the
The united nations agency on building codes
A zoning ordinance consists of
The zoning text and the zoning map of the city
Highest hurricanes. wind speeds are usually obtained in
Tornadoes
True of false A prescriptive building code provision is easier to enforce than a
True
True or false in the CMAA method of project delivery, there is normally no general contractor.
True
Which of the following beam cross sections is structurally more
Tubular section
The most fire-resistive type of construction is
Type I(A)
The International Building Code divides the types of construction
Types I II III IV V
When we determine the strength of concrete using the test specimens, we determine the concrete's
Ultimate compressive stress
The acronym UL stands for
Underwriters laboratories
A zoning ordinance refers to regulations that pertain mainly to
Use of land within the city
A material that is weak in tension is
Weak in shear
The region of the. United States that is relatively more earthquake prone is the
Western US
In the Master Format, windows are part of:
Windows
Which of the following is not a recognized building code occupancy?
an office
In the Master Format, Division 02 refers to:
existing conditions
In a typical building project, the coordination of the building's design is done by owner.
general contractor. building official of the city. architect.
The program for a building project is usually provided by the:
owner & the general contractor
material that is weak in tension is
weak in bending
The bending stresses along the neutral axis of a beam are
zero
When a cable or rope is compressed by a force, what is the compression stress in it?