In a flat-panel digital imaging system, electrons are converted into digital values by an ______

ADC

Which of the following is an EI used in flat-panel radiography A. EXI B. 'S' number C. DQE D. lglvl

B. 'S' number

All of the following are examples of EI's except: A. 'S' numbers B. DQE C. EXI D. REX

B.DQE

The addition of metal prothesis into the image data set affects: 1. image brightness 2. image contrast 3. the EI A. 1 & 2 B. 1 & 3 C. 2 & 3 D. 1, 2 & 3

D. 1, 2 & 3

PSP plates are erased after processing by exposing the plate to _______ - ________ _______

high-intensity light

A graphical representation of exposure values extracted from an image receptor is a _________

histogram

When using a flat-panel detector, the technologist does not touch the _______ _______

image detector

If a PSP plate is processed using the wrong anatomical menu, what could happen? The EI number may display _________

improperly

The acronym EI is a vendor - neutral term that stands for exposure ________

indicator

A type 2 histogram would be used when imaging the ____ ____ ____ _____

torso, spine, skull, pelvis

Scanning the bar code on a PSP plate is very important because it links the image data with the correct _____

patient

A DAP meter measures the patient dose as the x-rays enter the _________ ________

patient's skin

In a PSP plate reader, the light guide collects the light and directs it into a _______ _______

photomultiplier tube

What happens when a PSP plate reader is unable to identify the collimated borders of the image? The image quality is _______

poor

Neural analysis compares exposure data from the receptor with values in a _______ ______ _____

predetermined data set

Type 3 priori analysis is unique because it takes into account that patient characteristic?

prosthetic

Optimal EI ranges for each anatomical part should be set by the __________

radiologist

The ______ ______ device allows for an increased scanning precision compared with a mechanical arm

rotating mirror

A charge-coupled device and a complimentary metal oxide semiconductor need a _______ to change x-rays into light

scintillator


संबंधित स्टडी सेट्स

Concept A: Introduction to Anatomy

View Set

but, however, although, despite, because, so

View Set

Federal Tax Considerations for Life Insurance and Annuities

View Set

Salesforce Marketing Cloud Consultant Certification Exam Dump (All Combined)

View Set

PN VATI Management 2020 completed

View Set

EC309 Chapter 4: Monetary System

View Set

(THE ATMOSPHERE) Major Earth Science Concepts

View Set

Accounting 2101 Exam 1 Practice Questions

View Set

Describe the role of the SS in the years 1933-45

View Set

P.E. B Test 5- Stress and Health 1

View Set

Principles of Embalming III - PHT 414 Week 1

View Set