The sections of cast iron boilers are mainly designed to obtain maximum

Heat transfer

An altitude gage on a hot water heating boiler is used to indicate

Height of the highest radiator in the system

A hydramotor valve

Helps to prevent puffbacks

Boiler water foaming may be the result of

High TDS

An automatic fill valve

Opens only when expansion tank level is low

If a safety valve leaks after a try lever test, the operator should

Operate the try lever several times to blow away foreign material

The capacity of a constant capacity in mechanical atomizer is a function of

Orifice size

The cross section of a bourdon tube is generally

Oval

In a hot water heating system, the closed type expansion tank should be

Partly filled with water

Gas burners designed for heating boilers can be divided into two general classes

Pre and after mix burners

In a cast-iron modular heating boiler, the operation of the burner of each module is controlled by a blank that starts or stops modules in sequence of load demand increases or decreases

Step controller

Current code states that the feedwater pipe, before it enters the boiler must be fitted with a blank valve adjacent to the boiler

Stop

It is necessary to clearly Mark or identify valves and fittings so that

Strength and material can be applied for a particular use

On a pressure temperature indicator, if the pressure pointer Falls below the altitude pointer the

System is low on water

When the pressure pointer of a closed system reads lower than the altitude pointer the

System requires water

Popping pressure of a steam heating boiler safety valve may be adjusted

Up to 5%

The safety valve shall be installed in the blank position and located in the highest practicable part of the heating boiler proper

Vertical

Which of the following boilers is considered a single pass boiler

Vertical fire tube boiler and Steel plate heating boiler

The advantage of a vertical fire tube boiler is that it required

Very small floor space

One of the advantages of the fire tube boiler over water tube and tubular boilers is in the

Water treatment area

The furnace walls in a bent tube water tube boiler are formed by water filled tubes and these walls are called

Water wall

A globe valve should be used in the feedwater line

Whenever it may be used for control purposes

Most low capacity cast iron boilers

Will pass through standard size door ways

Should the steam line or water line to a gauge glass become plugged with sludge, the gauge glass

Will read high

How are stop valves that are used on steam outlet connections of heating boilers identified

With metal tags

The lowest visible part of the steam heating boiler water gage glass shall be at least blank mm above the lowest permissible water level recommended by the manufacturer

25mm

The scale on the dial of the pressure or altitude gauge on a hot water heating boiler shall be graduated approximately 2 not more than blank times the pressure at which the safety relief valve is set

3

According to the current code, the maximum blowdown for a steam heating boiler safety valve is

30 kPa

The amount of premix air to atmospheric burner should be

30% to 40%

In order to keep salt concentrations within safe limits, the package tubular steam boiler utilizes

An automatic blowdown

During warm-up of a cold hot water boiler, excessive pressure buildup IS prevented by

An expansion tank

To prevent flue gases from escaping in a cast-iron sectional boiler, the spaces between the sections are sealed with high temperature

Asbestos rope

An agency or cold with which fittings must comply is

Asme code

The term heating plant is defined in

Asme section 4 and Alberta Power Engineers regulation

How many pressure relief valve on a hot water heating boiler have

At least one

The temperature indicator of a hot water boiler should indicate water temperature

At the boiler Outlet

The reduction of oil into very small particles is termed

Atomization

A closed type expansion tank on a hot water heating system must

Be partially filled with air at all times

Boiler blowdown lines have a specific size range based on

Boiler capacity

The ratio of heat released to heat transferred to the boiler water is known as

Boiler efficiency

If the boiler pressure increases then the

Bourdon tube will tend to straighten

The copper tube tubular boiler

Can be gas or oil fired

Cast iron boiler capacity

Can be increased by simply adding sections

A hot water boiler pressure relief valve

Can be installed anywhere in the system but preferably close to the expansion tank

Name of the different methods by which oil can be atomized for burning

Care, steam, mechanical, rotary cup

Your boiler is operated with automatic water feeders. If the boiler suddenly requires an increase in water treatment, what should you look for.

Check for a loss of feedwater

Try cocks are used to

Check the level of water in the boiler

If the power is cut off to an automatic gas valve, the valve will

Close immediately

The two basic varieties of mechanical atomizing oil burners are the

Constant capacity burner & modulating burner

The blank pilot is most often used on a small boiler

Continuous

Modular cast iron boiler water flow is

Continuous through all modules

The pilot burner for gas fired heating equipment can be

Continuous, interrupted and intermittent.

Heating boilers attain maximum efficiency only when they are operated

Continuously at full load

A reason for preferring copper tubing in a tubular boiler is

Corrosion resistance

To maintain high gas velocities through all gas passes in a 4 pass fire tube boiler, the cross-sectional area of each succeeding passes

Decreased

In a closed expansion tank system, an air separator

Direct air into the expansion tank

The force of the steam pressure acting on the safety valve discharge is a function of

Disc area

A steam boiler is blown down in order to

Discharge sediment and scale forming matter from the boiler

An initial problem with the tubular boiler being used as a steam unit was

Dissolved impurities forming scale on the tube

A pressure or altitude gauge for a hot water heating boiler

Does not require a siphon. Because there is no Steam

When too much air has been absorbed by water in the expansion tank of a closed system, the tank must be

Drained

One of the advantages of the low pressure Serpentine tube water tube boiler is

Ease of replacement of defective tubes

The Friends cast on the flat surface of the sections of a cast-iron sectional boiler are used for the purpose of increasing the

Effectiveness of heat transfer

A function of a bourdon tube gage hairspring is to

Eliminate backlash

One of the advantages of the low pressure Serpentine tube water tube boiler is virtually

Eliminate expansion and contraction stresses

One of the earliest fire tube boilers was the

HRT boiler

A membrane water wall

Has metal connecting the tubes

An internally fired boiler

Has the furnace surrounded by water

Smaller fire tube boilers are low cost and

Have simple rugged Construction

A steel plate vertical fire - unit is divided into two sections and the upper part is often called the

Heat exchanger

A disadvantage of a gauge glass safety shut-off valve is

It requires more maintenance

When a gas fired burner is burning fuel properly

It will have a blue flame with short yellow tips

When a packaged fire tube boiler is used as a power boiler rather than a heating unit

It will have a much stronger design

A cast iron boiler disadvantages

It's pressure limitations

A disadvantage of the water tube or tubular boiler is

Its water treatment monitoring

A siphon tube is necessary to

Keep steam out of bourdon tube

A siphon on a boiler is necessary to

Keep steam out of the bourdon tube

A steam pressure gage is graduated in

Kilopascals

An intermittent pilot

Lights the main flame and remains on with it.

The popping action of a safety valve is due to the

Lip on the valve disc

The combustion chamber of a serpentine tube water tube boiler is

Located below the tubes

The advantages of a package boiler are

Lower freight costs because of less handling. Lower initial cost because they are mass produced. Quality control is easier to implement. the boilers can be Factory tested before being sent to the customer. It requires little time to put the unit into operation at the plant.

Steam heating boilers must be equipped with a marker indicating the

Lowest permissible water line

The chief advantage of a package boiler is that it can be

Mass-produced

To which of the following oil burners is the oil supplies under high pressure

Mechanical atomizing burner

The working medium in the dead weight tester is

Medium weight oil

A steam heating boiler safety valve lever test should be performed

Monthly

Testing the safety valve by means of the try lever method, is considered good practice when carried out on a

Monthly basis

Boiler blowdown piping

Must be full size to the point of discharge

Open type expansion tanks

Must be located above the heating system

Boiler fittings

Must be registered by the government

One of the advantages of using natural gas as a fuel in a boiler is

No storage space is required.

At what other point, besides being connected to the boiler, put an expansion tank in a closed water heating system be located

On the supply Maine

What limits the height of a package boiler

Transportation requirements

The lip on a safety valve

Allows it to pop open

How many blow off valves does a steam heating boiler require

1

The scale on the dial of the pressure or altitude gauge on a hot water heating boiler Shelby graduated approximately 2 not left then blank times the pressure at which the safety relief valve is set

1.5

Low pressure heating boilers are those that operate below

100 kilopascals

According to current code, steam heating boilers shall have one or more safety valves, adjusted and sealed to discharge at a pressure not exceeding blank kPa

103

Low pressure hot water heating boilers are those that operate below

1100 kilopascal

According to current code, no safety valve on a steam boiler shall be larger than

110mm or 4.5 in

According to the current code, no safety valve on a steam heating boiler shall be smaller than

12.7 mm or 1/2 inch

According to current code, the valve seat diameter of the safety valve on a steam heating boiler must not be smaller than

12.7mm

Low pressure hot water heating boilers are those that operate below

120 degrees Celsius

The temperature reading of valves and cocks used for blow-off or drain purposes on a steam out hot water heating boiler shall be not less than

121 degrees Celcius

The current code states that each steam heating boiler shall have one or more water gauge glass attached either directly to the boiler or to a water column by means of valve fittings not less than blank mm size

15

According to the current code, the minimum blowdown for a steam heating boiler safety valve is

15 kPa. Max is 30 kPa

The pressure control connection to a steam heating boiler taping, -, or piping to the boiler shall not be less than blank wear steel, wrought iron piping or tubing is used

15 millimeters

The water column water connection for a cast-iron sectional steam heating boiler shall be made on an end section not less than blank below the bottom connection to the water gauge glass

150 millimeters

The minimum size of the drain piping, valves and cocks of a steam out hot water heating boiler shall be

19 mm

A minimum distance from furnace to oil storage tank is

2.1 meters

For hot water boilers operating up to 400 kilopascals, a pressure relief valve opening pressure tolerance maybe as much as

20 kilopascals

The minimum pressure rating of valves and cocks used for blow-off or drain purposes on a steam out hot water heating boiler shall be at least equal to the pressure stamped on the boiler, but in no case less than

200 kPa

According to the current code, no safety relief valve on a hot water heating boiler shall be smaller than

20mm

What is the minimum size of the connecting pipes attached to his steam heating boiler

25 millimeter

For a steam heating boiler, the safety valve shall be such that, with the fuel burning equipment installed and operated at maximum capacity, the pressure cannot rise more than blank above the maximum allowable working pressure when all steam outlets are closed

35 kPa

If the safety valve on a steam heating boiler opens, what is the pressure above the maximum allowable working pressure that the boiler is allowed to rise

35 kPa

The water column drain pipe and valve on a steam heating boiler shall not be less than

51 mm

Burner light oil supply pressure range is approximately

550 - 700 kPa

Before out of migration can occur, heavy oils are heated to approximately

95 degrees Celsius

Before entering the boiler, the feed water pipe must contain

A check valve, and hey stop valve in between the check valve and the boiler

Gauge glass rupture may be caused by

A cold draft

A closed expansion tank is usually equipped with

A gage glass

A modulating pressure atomizer has its return oil flow regulated by

A modulating valve in the return line

An air atomizing compressor is usually

A positive displacement type

Oil flow rates to a modulating burner is regulated by

A return line, modulating valve

A hot water boiler is protected from overpressure by means of

A safety relief valve

What does the boiler inspector install to prevent tampering with a safety valve setting

A seal

The blowdown on a safety valve is adjusted by turning the

Adjusting ring

Oil burners can be divided into three classes

Air and steam atomizing burners. Mechanical or pressure atomizing burners. And centrifugal or rotary cup burners

The purpose of the small vent valve or cock on top of the shell or on top of the water column on most boilers is to allow

Air to escape whole the boiler is being filled.

The term fitting is defined in

Alberta pressure equipment safety regulation

Water column supply line crosses will

Allow for piping cleaning and inspection.

An expansion tank is used to

Allow for the expansion of the water

On a multiple steam heating boiler system, a stop valve must be placed at each boiler Outlet valve to

Allow the boiler to be isolated from the system

Boilers are designed with more combustion gas passes

Allowing more heat to be absorbed from the combustion gases increasing boiler efficiency

The air released from the water in the closed expansion tank type hot water heating system is directed to the

Expansion tank

Cast iron boiler sections maximize heat transfer by

Exposing as large a surface as possible to the hot gases

True or false. Steel plate heating boilers use normal tubes to allow the combustion gases to flow through the boiler

False. They use fire tubes with thin steel strips installed on the inside of the tubes to promote a swirling motion to the gas

A reason for preferring copper tubing in a tubular boiler is

Faster heat transfer rate

In order to maintain gas velocity throughout all boiler passes a fire tube boiler have

Fewer tubes in each pass so that tubes of the same size can be used

When the hot combustion gases travel through boiler tubes which are surrounded by water, the boiler is called a

Fire tube boiler

A stop valve is fitted between the boiler and the feed water check valve

For isolation and to create a positive shut-off

When a packaged fire tube boiler is used as a hot water unit

Forced circulation is required

According to the current code, the scales on a pressure gage for a steam heating boiler shall be graduated between one of the following

From 200 to 414 kPa

Atmospheric burners are used for

Gas stoves, hot water heaters, heating furnaces and many heating boilers

Boiler outlet valves are usually

Gate valves because of their low resistance to flow

The venturi tube in the atmospheric burner mixing head has a

Gradually increasing cross-sectional area

In order to ensure a safety valve seats properly, it uses

Guides and bushings

A hot water tank is not considered to be a heating boiler unless one of the following is exceeded

High capacity greater than 454 liters. A temperature greater than 93 degrees Celsius. An energy input of greater than 58.6 kilowatts

One of the reasons that industrial type watertube boilers are seldom selected for low-pressure heating plants

High cost

A refractory burner disadvantage is

High initial cost

When the water connection between the boiler and the gage glass becomes plugged, the water level in the glass will eventually show a level that is

Higher than level in the boiler.

Regarding fire to boilers, HRT stands for

Horizontal return tubular

The purpose of the pipe siphon installed between the boiler and the pressure gage is to prevent

Hot steam from entering the gage.

A boiler feedwater stop valve

I'd used to isolate the feedwater line

boiler stop valve shall be

Identified with durable tags

LP boiler safety valves can be repaired

In Canada, provincial regulations state By a qualified boiler operator after permission from the inspector. Otherwise only from the manufacturer.

To increase the opening pressure of a safety valve

Increase spring compression

Boiler water legs

Increase the heating surface

An operator should check that a boiler safety valve will open at its set pressure by

Increasing the boiler pressure until the valve opens, noting the pressure on the pressure gage when the valve opened

The purpose of the test connection on a boiler pressure gage is to

Install a boiler inspectors pressure gage

A solenoid type fuel valve

Is held closed by fuel pressure

An inspectors test connection

Is not mandatory on LP boilers

When using a dead weight tester, the effect of friction

Is reduced by rotating the platform

When a closed type expansion tank on a hot water boiler is completely filled with water, and the water in the system is raised in temperature so that it expands, the result will be that the

Pressure build-up opens the safety relief valve

On a steam heating boilers, the safety valve test lever must not be used unless

Pressure is at least up to 34 kPa

The purpose of the deflector vanes in the center of a ring burner are to

Promote turbulence of gas and air mixture.

The main function of a gas burner is to

Provide intimate mixing of gas with combustion air

The main function of a gas burner is

Provision of air fuel contact

In order to prevent the possibility of a furnace explosion, it is important that the furnace is blank before the ignitor is energized and fuel is supplied to the burner nozzles

Purged

Sectional cast iron boiler sections are connected with

Push nipples

The Steam and water spaces of a cast-iron sectional boiler are connected by

Push nipples

The quick closing valves on the water gauge only require a blank turn of the valve spindle to change the valve from full open to full closed

Quarter

The use of bent tube boiler design allows the furnace wall to be lined with tubes, thereby exposing more of the heating Surface 2

Radiant heat

An outside screw and yoke valve

Readily shows its position

Blank burner haeds are most common for use in heating boilers

Rectangular

An atmospheric burner head which is very popular on heating boilers is the

Rectangular type

All boiler fittings not properly or clearly identified should be

Rejected

A fitting that is not clearly identified should be

Rejected completely

Quick closing gage glass valves

Require 90 degrees for full travel

Packaged fire tube boilers

Require relatively small building volumes

A very popular packaged boiler gas burner is the

Ring burner

The boiler steam outlet stop valve should be a

Rising stem gate valve

The prime importance of boiler fittings is

Safety

An advantage of a packaged low pressure tubular or water tube boiler is

Safety due to the low volume of water it contains

The following fittings should be found on a steam heating boiler

Safety valve, water gage glass, low water cutoff

The Forerunner of the modern packaged fire tube boiler was the

Scotch Marine boiler

An atmospheric premix burner has air entering around the burner that is termed

Secondary air

The bent tube boiler designs allows the tubes to be attached radially on the outside of the

Shell or drum

When installing a siphon, it

Should be first filled with water

Large capacity burners

Should have minimum flow on ignition

If you found the safety valve on your heating boiler stuck in the closed position while the boiler was I operation, the best thing to do is

Shut down the boiler and repair or replace the safety valve.

In a vertical sectional boiler, the sections are placed

Side by side

As essential fitting between the boiler and the steam pressure gage is a

Siphon

The advantage of motorized or hydramotor gas valve is that the valve opens blank, thus preventing furnace puff

Slowly

A relief valve is placed on the discharge of a fuel oil pump

So burner design pressure is not exceeded

Hot water heating boilers have stop valves in their Inlet and Outlet piping

So that the boiler can be drained without draining the system

Low pressure boilers are made of

Steel and cast iron

A fire tube boiler commonly used for hot water heating systems in residences and small apartments is the

Steel plate vertical unit

One of the advantages of the refractory gas burner is

The air and gas mixture is thoroughly preheated before it enters the furnace

When a closed expansion tank is used in the system is cold

The auto-fill of valve will maintain a system minimum pressure

A cast iron boiler Advantage is

The choice of assembly locations

Blowdown of a safety valve is defined as

The difference between opening and closing pressures

A packaged tubular steam boiler Austin has a steel sheeting in front of the water wall tubes due to

The erosive action of the flame

When the gauge glass nuts are leaking

The glass should be isolated and depressurized before tightening,

An indication of a pressure gage not performing properly is

The needle not returning to zero on depressurizing

A multi burner cluster has secondary and tertiary nozzles ignited by

The primary burner

Can a hot water system, if the pressure pointer on a pressure temperature indicator Falls below the altitude pointer, what does this mean

The system is not full of water

If a heating boiler with an automatic feed water system requires a large amount of water to be fed manually, this may indicate

There is probably a leak in the system

Hot water heating boilers must be equipped with a

Thermometer

Which of the following fittings would you expect to find on a hot water heating boiler

Thermometer, safety relief valve, blow off or drain valve.

In a low-pressure serpentine watertube boiler, the serpentine tubes are attached to upper and lower headers with blank connections

Threaded

A fuel filter consists of

Three main parts

The Steam and water spaces of a cast-iron sectional boiler are held together by

Tie rods

Gauge glass may be surrounded by a number of thin metal rods

To protect the glass

Purpose of hairspring on bourdon tube gage

To take up any backlash or play between teeth of the pinion gear

According to current code, for what distance from a boiler shall a blow-off pipe be full size

To the point of discharge

Initially, the fire tube boiler was not up to manufacturing expectations because

Too many equipment suppliers were involved in its manufacture


संबंधित स्टडी सेट्स

Child Health - Archer Review (3/3) - Growth & Development, Infectious Disease, Endocrine, Urinary/Renal/ Fluid and Electrolytes, Visual/Auditory

View Set

AP Biology- Unit 5 GENETICS REVIEW

View Set

ELIE WIESEL'S REMARKS AT THE DEDICATION OF YAD VASHEM HOLOCAUST HISTORY MUSEUM

View Set

Chapter 14: Capitalism and Economy - Inquisitive Questions

View Set

Restorative Art - Muscles of Form and Expression test 2

View Set

English II Unit 7 - Bias, Media, and Persuasion

View Set