Ch 3 : Use and occupancy classification
A Group __________ occupancy is the general classification for miscellaneous and utility structures.
U (302.1)
Which of the following uses is not considered a Group B occupancy?
convenience store (304.1)
Which of the following uses is typically considered a Group A-4 occupancy?
indoor hockey arena (303.5)
In a Group E middle school, an assembly area associated with the Group E shall be separated at what minimum level from the remainder of the school building?
no separation is required (considered same occupancy) (301.1.3)
Accessory religious educational rooms need not be considered separate occupancies where the occupant load is less than ___________ occupants.
100 (303.1.1)
An accessory assembly area may be classified as a Group B occupancy where the floor area is a maximum of ____________square feet.
750 (303.1.2 #2)
The gaming floor of a casino shall be classified as a Group ___________ occupancy?
A-2 (303.3)
An institutional occupancy is typically considered Group ______ .
I (302.1)