Lesson Assessment #18
Receptacle outlets in or on floors shall not be counted as part of the required number of receptacle outlets for dwelling unit wall spaces, unless they are located within _____ in. of the wall.
18
There shall be a minimum of one _____ branch circuit for the laundry outlet(s) required by 210.52(F).
20 A
The recommended maximum total voltage drop on branch circuit conductors is _____ percent.
3
The total rating of utilization equipment fastened in place, other than luminaires, shall not exceed _____ percent of the branch circuit ampere rating where lighting units and cord and plug connected utilization equipment not fastened in place are supplied.
50
Appliance receptacle outlets installed for a specific appliance in a dwelling unit, such as laundry equipment, shall be located within _____ of the intended location of the appliance.
60 ft
For the purposes of 210.71, examples of rooms that are not meeting rooms include _____.
auditoriums schoolrooms coffee shops
In addition to the number of branch circuits required by other parts of 210.11, at least _____ 120V, 20A branch circuit shall be provided to supply the bathroom(s) receptacle outlet(s).
One
120V, single phase, 15A and 20A branch circuits supplying _____ installed in dormitory unit bedrooms, living rooms, hallways, closets, bathrooms, and similar rooms shall be protected by any of the means described in 210.12(A)(1) through (6). outlets
Outlets, devices
The Code provides rules for the minimum number of receptacle outlets required in a dwelling unit. The minimum required receptacle outlets shall be in addition to receptacle outlets that are _____.
part of a luminaire or appliance controlled by a wall switch for use as required illumination located more than 5 1/2 ft above the floor
120V, single phase, 15A and 20A branch circuits supplying outlets and devices installed in guest _____ of hotels and motels shall be protected by any of the means described in 210.12(A)(1) through (6).
rooms, suites