My Sample test

अब Quizwiz के साथ अपने होमवर्क और परीक्षाओं को एस करें!

Joist bearing on a concrete foundation must be a minimum of: A. 3 inches. B. 2.5 inches. C. 1.5 inches. D. 2 inches.

A. 3 inches.

What is the MAXIMUM distance between foundation anchor bolts for sill plates? A. 6 feet. B. 4 feet. C. 18 inches. D. 2 feet.

A. 6 feet.

In a 1987 conventional wood-frame house, which one of the following signs (by itself) is a significant problem? A. A 1/2 inch wide wall/floor separation B. A long, straight, vertical hairline crack in one room, roughly 1 inch away from wall corners C. A hairline crack in the second floor ceiling next to the exterior wall D. A hairline crack over the corners of two doorways on the second floor

A. A 1/2 inch wide wall/floor separation

The water heater pressure relief valve discharge pipe MUST be: A. As large as the relief valve outlet B. Threaded at the bottom. C. A 3/4 inch pipe. D. Made of rigid pipe.

A. As large as the relief valve outlet

To measure carbon monoxide, you should use a(n): A. CO detector. B. CO2 detector. C. OC detector. D. OC2 detector.

A. CO detector.

Mortar used in brickwork may vary in composition, but always contains: A. Cement, lime, and sand. B. Cement, clay, and pumice. C. Lime, sand, and adobe. D. Lime, sand, and clay.

A. Cement, lime, and sand.

Generally, which type of item is NOT included in a home inspection? A. Cosmetic. B. Not present. C. Unsafe. D. Defective.

A. Cosmetic

Smelling sewer gas near a bathroom sink indicates that the drain trap is: A. Dried out B. Flooded C. Clogged D. Undersized

A. Dried out

GFCI protection is now REQUIRED for: A. Garage recepacles. B. All multi-wire branch circuits. C. 240 volt pool pump motors and pool sweep motors. D. Dishwasher and disposer receptacles.

A. Garage recepacles.

A main beam that supports floor joists is often called a: A. Girder B. Stringer C. Purlin D. Joist carrier

A. Girder

The causes of roof decking buckling include: A. Improperly installed materials that do not allow for expansion. B. Improperly applied moisture barrier and roof shingles. C. Lack of panel clips and insulation. D. Lack of nails and gluing decking to the rafters.

A. Improperly installed materials that do not allow for expansion.

Sewage ejector pumps are necessary when a toilet: A. Is below the sewer line. B. Backs up frequently. C. Is far from the main sewer stage. D. Is below the septic drainage field.

A. Is below the sewer line.

What type of foundation has a large amount of reinforced steel and is known as a floating foundation? A. Mat foundation slab. B. "Battered" foundation footing system. C. Pier-and-grade beam foundation system. D. "Inverted T" spread footing foundation.

A. Mat foundation slab

Three-hole grounding-type electrical receptacles: A. Must be grounded. B. Cannot be installed downstream of an ungrounded GFCI. C. Are required to have an insulated ground. D. Must connect to the nearest water pipe.

A. Must be grounded.

While inspecting a one-year-old house, slab on grade, you observe hairline cracks in the concrete floor with no vertical displacement. This indicates: A. Normal plastic shrinkage. B. Overhydrated concrete. C. Insufficient reinforcement. D. Unstable subsoil.

A. Normal plastic shrinkage.

You observe approximately 12 inches of loose fill fiberglass insulation in an attic space. You advise the client that the "R" value is approximately: A. R30. B. R19. C. R11. D. R13.

A. R30.

You are approached by a real estate agent/broker to advertise in their office brochure for a fee. In turn, they will promote your firm as a preferred vendor and recommend you. You should: A. Refuse since it is a violation of ethical practice. B. Refuse because such an arrangement may compromise your integrity. C. Accept since it is an acceptable method of marketing. D. Accept only if there is nothing which precludes your responsibility to your clients.

A. Refuse since it is a violation of ethical practice.

Soil surface adjacent to the foundation should be: A. Sloped away to provide proper drainage. B. Covered by granular soil. C. Sealed to prevent water entry. D. Compacted to provide foundation support.

A. Sloped away to provide proper drainage.

Leaks in gas piping can be detected by: A. Soapy water B. Discoloration. C. Condensation. D. Corrosion.

A. Soapy water

During your inspection you see small white insects. What do you say to your clients? A. Suggest obtaining the services of a pest control operator. B. There is damage to the structure due to an insect infestation. C. Do not say anything. D. There are termites in this property.

A. Suggest obtaining the services of a pest control operator

It is discovered that a 3" deep notch is cut at the end of a 2X10 floor joist. The home inspector's report should include: A. That the notch exceeds maximum allowable depth and needs proper repair. B. That no repair is needed because it is in the other 1/3 of the joist. C. Nothing about this because it does not exceed 35% of the depth of the joist. D. That the notch needs proper blocking.

A. That the notch exceeds maximum allowable depth OF 1 1/2 and needs proper repair.

Two roof trusses passing above an interior hallway have been cut to install a pull-down attic ladder. There is no cracking or indication of distress in the walls or ceilings. Which of the following is the MOST appropriate action? A. The inspector should recommend this situation be referred to a structural engineer. B. The inspector can evaluate the remaining pieces of the trusses as if they were site-built. C. This is not a concern since this is no indication of stress. D. This is beyond the scope of an inspection and does not need to be reported.

A. The inspector should recommend this situation be referred to a structural engineer.

If a well pump cycles on and off rapidly, it is an indication that: A. The pressure tank is probably water logged. B. There is a leak in the well supply pipe. C. Someone is turning a faucet on and off. D. The pressure switch is out of adjustment.

A. The pressure tank is probably water logged

You are inspecting a home built in 1996. In the garage you observe the walls are covered with 1/4 inch hardboard panels. You advise the client that: A. There does not appear to be any fire barrier between the garage and living space as currently required. B. Hardboard panels are excellent for a moisture barrier between the house and garage. C. The walls do not meet crush resistance requirements and should be replaced. D. The wall is properly sheathed, and no action is needed.

A. There does not appear to be any fire barrier between the garage and living space as currently required.

Which of the following is a safety mandate in a remodeled home where a hydro-massage bathtub has been added? A. There must be a ground fault circuit interrupted B. There must be a vacuum breaker. C. The faucets must be at the drain end. D. The tub area must have a venting fan.

A. There must be a ground fault circuit interrupted

Which of the following roofing materials is the heaviest? A. Tile or slate B. Wood shakes C. Gravel-surfaced built-up roof. D. Asphalt shingles over wood shingle

A. Tile or slate

If your inspection mirror fogs when places near a gas water heater draft hood the: A. Unit may not be venting properly. B. Water heater should be replaced. C. Water heater has an internal leak. D. Temperature of the water is too hot.

A. Unit may not be venting properly.

Looking into an open electric service panel you see a wire with evidence of burning. What should you do? A. Report on the condition, and inform the homeowner that an electrician should review. B. Disconnect the wire, cut the burned area off, and strip and reconnect the wire. C. You are not responsible for removing electric service panel so this situation will never occur. D. Check the wire to see if it is hot and then tighten any loose connections.

Answer A. Report on the condition, and inform the homeowner that an electrician should review.

To avoid scalding injuries, heating elements should be sent to: A. 130 degrees Fahrenheit. B. 120 degrees Fahrenheit. C. 100 degrees Fahrenheit. D. 110 degrees Fahrenheit

Answer B. 120 degrees Fahrenheit.

While inspecting the furnace you detect very high levels of carbon monoxide at the supply air registers. You should: A. Explain that the unit will need servicing in the future to prolong its life. B. Open windows, shut down systems, and advise immediate evaluation by an HVAC contractor. C. Advise that everyone run out of the house for safety. D. Immediately shut off the main gas valve to disable the unit.

Answer B. Open windows, shut down systems, and advise immediate evaluation by an HVAC contractor.

It is recommended that stucco sidewall finishes on houses with more than one story should be ______ framed. A. Platform. B. Post-and-beam. C. Balloon. D. Steel

Answer C. Balloon.

The MINIMUM width of stairways (not considering railings) is: A. 44 inches. B. 42 inches. C. 27 inches. D. 36 inches.

Answer D. 36 inches.

The term "wet vent" refers to a: a. Vent that traps water and therefore stays wet. b. Vent located above the roof line and exposed to rain. c. Vent that runs outside an exterior wall. d. Waste line that also functions as a vent.

Answer D. Waste line that also functions as a vent.

Subflooring may be omitted when a 1-inch nominal tongue-and groove wood strip is applied perpendicular to the joists and the joist spacing does NOT exceed: A. 18 inches. B. 16 inches. C. 12 inches. D. 14 inches.

B. 16 inches

A flame of sparking device within gas appliances MUST be elevated off the garage floor AT LEAST: A. 24 inches. B. 18 inches. C. 6 inches. D. 12 inches.

B. 18 inches.

Which deficiency should be considered an immediate potential safety hazard? A. Worn-out and leaking chimney flashing. B. A missing temperature and pressure relief valve on a hot water heater. C. A 1/8 inch diagonal crack in a foundation wall. D. Missing attic insulation around a skylight.

B. A missing temperature and pressure relief valve on a hot water heater.

Historically, spaced sheathing has been used for roof decking because it: A. Retards attic ventilation. B. Allows for drying of roof material. C. Is economical and strong. D. Provides a safe walking platform.

B. Allows for drying of roof material

While inspecting a home, you observe a large ceiling fan with built-in lamps. This installation requires a(an): A. Larger junction box. B. Approved brace or box. C. Strong ceiling. D. Pancake junction box.

B. Approved brace or box.

Water heaters are NOT allowed in: A. Laundry rooms open to the living area. B. Closets of bedrooms or bathrooms. C. Basements accessible only from interior stairs. D. Attics accessibly only from a permanent ladder.

B. Closets of bedrooms or bathrooms.

Ivy has grown across the entire exterior brick wall surfaces of a one-family house. The home inspector should report that the ivy: A. Needs additional maintenance and support to remain on the wall surfaces. B. Could cause damage to the surface and recommend removal. C. Will increase the resale value. D. Will keep the home cooler in the summer.

B. Could cause damage to the surface and recommend removal.

What appliance may vent into a chimney along with an oil-fired furnace if allowed by local code? A. Kitchen vent. B. Gas water heater. C. Bathroom vent fan. D. Woodstove.

B. Gas water heater.

When inspecting a home, the seller of the property has made the statement that all the appliances are in working order. As an inspector, you should: A. Assume the seller is hiding a problem, and report your suspicion to the client. B. If you inspect appliances, tell your client that you will check them out. C. Take the seller's information for granted, and do not test any appliances. D. Say nothing about the appliance in the report.

B. If you inspect appliances, tell your client that you will check them out.

Damage from ice dams could indicate: A. Attic vents left open during winter months. B. Insufficient attic insulation. C. Over-exposure of shingles or slates. D. Rain gutters with too low an outer lip.

B. Insufficient attic insulation.

When a water heater thermostat is set at 140 degrees Fahrenheit or higher, a _____ should be installed to temper the water. A. Temper Valve. B. Mixing Valve. C. Temperature Probe. D. Mixing Probe.

B. Mixing Valve.

A common term for the supply pipes going from the basement ceiling to the upstairs bathroom is: A. Leaders. B. Risers. C. Verticals. D. Stacks.

B. Risers.

The purpose of a thermocouple is to: A. Control fan. B. Shut gas off. C. Control temperature. D. Adjust flame.

B. Shut gas off

The MAXIMUM number of throws required to disconnect all power at the service is: A. Eight. B. Six. C. Two. D. Four.

B. Six

Which of the following is TRUE with regard to powder post beetles? A. They are known as "deathwatch" beetles. B. They create exit holes which are approximately 1/16 inch in diameter. C. They are normally detected by listening for the "clicking" sound they make when chewing on wood. D. Their presence is confirmed when shelter tubes are reconstructed after damage.

B. They create exit holes which are approximately 1/16 inch in diameter.

An electrical wire that is hanging loose with a bare end is seen in the attic of a home. The homeowner says it is an abandoned circuit and is not being used. The quickest way to check the wire is to: A. Use an amp meter. B. Use a voltage "sniffer". C. Touch the bare end with your fingers. D. Believe the homeowner because he knows his house.

B. Use a voltage "sniffer".

Which of the following is the MOST secure way to attach exterior deck joists to a ledger (or band joist)? A. Use screws angled through the ends of the joists to the ledger B. Use joist hangers nailed to both the joist and the ledger C. Toenail the joists to the ledger from both sides of the joist D. End nail through the ledger into the joists before installing the ledger

B. Use joist hangers nailed to both the joist and the ledger

Which of the following is the correct termination where the sloped roof terminates with an EIFS wall? A. Use only step flashing that is overlapped three inches. B. Use kick-out flashing into the gutter. C. Use polyurethane caulking between the gutter and the wall. D. Use silicone caulking between the gutter and the wall.

B. Use kick-out flashing into the gutter

The proper slope on a drain line is: A. No slope. B. 1 inch per foot. C. 1/4 inch to 1/2 inch per foot. D. Less than 1/4 inch per foot.

C. 1/4 inch to 1/2 inch per foot.

In order for soffit vents to operate properly, there MUST be: A. Continuous vent strips on the length of the soffit. B. Vents on both ends on the outside. C. A clear air channel between the roof boards and the insulation. D. An absence of insect, bee, and bird nests.

C. A clear air channel between the roof boards and the insulation.

When testing the GFCI test/reset device in the hall bathroom, you discover that the power shuts off to the outlets in the remaining bathrooms as well. You conclude: A. The entire circuit is illegal since each bathroom GFCI outlet must be provided with a dedicated control. B. The GFCI test/reset device is properly wired; however, test/reset devices are needed at the other outlets. C. All these outlets are properly wired on the same GFCI protected circuit, and no correction is needed. D. All these outlets are improperly wired on the same GFCI protected circuit, and correction is needed.

C. All these outlets are properly wired on the same GFCI protected circuit, and no correction is needed.

The purpose of a sanitary trap is to: A. Regulate waste flow. B. Eliminate radon. C. Block sewer gas. D. Catch objects.

C. Block sewer gas

The joints on the exterior of the brick chimney should be: A. Closed. B. Open. C. Concaved. D. Raked.

C. Concaved

Which statement BEST describes the action a home inspector should take when a safety issue is found in a home? A. Shut down the system and call a repair contractor. B. Repair the problem when possible. C. Determine the degree of immediacy, and report to the appropriate parties. D. Explain verbally to the client, but do not include in a written report.

C. Determine the degree of immediacy, and report to the appropriate parties

Water is dripping from the cold water pipes above a gas water heater. This might be caused by: A. Overfiring. B. A cold start. C. Exhaust spillage. D. Short cycling.

C. Exhaust spillage.

On a previous work day, you left a crawl space access cover off of the access to the pantry. A party fell the next day and was injured. Which of the following insurance types will be used to pay damages? A. Claims made and occurrence. B. Errors and omissions and broker liability. C. General liability and bonding. D. General liability and homeowners' coverage.

C. General liability and homeowners' coverage

In a forced air furnace, the burners are used to generate heat in the: A. Plenum. B. Flue. C. Heat exchanger. D. Draft diverter.

C. Heat exchanger.

Which of the following is currently required to be GFCI protected? A. Garbage disposer. B. Dishwasher. C. Hydromassage tub. D. Attic outlets.

C. Hydromassage tub.

A toilet in a residential bathroom: A. Requires a minimum four-inch drainpipe. B. Cannot be tightly sealed to a smooth floor such as sheet vinyl. C. Is secured to the plumbing "closet flange" by two closet bolts. D. Is not allowed to have a double wax ring.

C. Is secured to the plumbing "closet flange" by two closet bolts

Polybutylene (PB) water supply tubing is seen in the house. You should report that it: A. Is not a problem. PVC pipe is a problem. B. Should only have been used to waste pipe. C. May require expensive replacement. D. Is illegal to use this kind of pipe.

C. May require expensive replacement.

When inspecting a home, you note horizontal cracks. Which of the following would NOT be a cause of overload from the outside? A. Backfill B. Soil pressure C. Moisture D. Frost

C. Moisture

Which of the following is an indication that a masonry wall is veneer and NOT structural? A. There are no arches in the wall. B. The windows are inset 6" from the wall face. C. No bond courses are seen. D. The lintels are made of steel.

C. No bond courses are seen.

A room is built over a garage, with floor joists parallel to the garage door opening. To allow room to install a double-wide automatic garage door opener, the center of the joists may _____. A. Be notched only if a tension rod goes under the opener hardware. B. Be notched up to 1/6th their depth. C. Not be notched. D. Be notched up to 1/8th their depth.

C. Not be notched.

A common place for steel enamel sinks to "rust out" and leak is the: A. Drain control. B. Bowl clamps. C. Overflow channel. D. Sink rim.

C. Overflow channel

The purpose of anchor bolts in a sill plate is to: A. Prevent wall misalignment. B. Prevent wall collapse. C. Prevent movement. D. Prevent wall racking.

C. Prevent movement.

Ledger boards should be securely attached directly to the house by: A. Properly sized lag bolts into the foundation ledge. B. Properly sized joist hangers for the house. C. Properly sized lag bolts every 16 inches. D. galvanized nails placed every 16 inches.

C. Properly sized lag bolts every 16 inches.

During an inspection of a gas dryer, you observe no exhaust vent. Your report should: A. Recommend installing a flexible plastic dryer duct vented to the exterior. B. Indicate a code violation and state that corrective action should be taken. C. Recommend installing a metal dryer duct vented to the exterior. d. Indicate that this is not a problem because a stocking is placed above the opening lint trap.

C. Recommend installing a metal dryer duct vented to the exterior.

The following plumbing fixture valves should all be operated EXCEPT: A. Showers and tubs. B. Sink faucets. C. Shut-off valves. D. Hose bibbs.

C. Shut-off valves.

The functions of screened metal chimney caps include all of the following EXCEPT: A. Retarding rainwater penetration into the flue B. Preventing the entry of birds and other animals. C. Slowing the draft that accelerates at the top of the flue. D. Preventing the escape of sparks and embers.

C. Slowing the draft that accelerates at the top of the flue.

Inspection of the outside brick work over a window shows a horizontal crack. The cause of the crack is: A. Brickwork too close to wall sheathing. B. Missing wall tiles. C. The rusting of steel lintels is causing the expansion. D. Brickwork is not installed properly.

C. The rusting of steel lintels is causing the expansion.

What type of vent pipe material is allowed to run through a ceiling, roof, or wall for a natural gas appliance? A. Single-wall galvanized steel. B. Black steel, as long as there is nine-inch (9") clearance to combustibles. C. Type "B" UL approved. D. Type "A" UL approved.

C. Type "B" UL approved.

Which of the following describes partial vapor pressure? A. Water vapor is an indication of sick house syndrome. B. Water vapor is common with forced induction natural gas furnaces. C. Water vapor has a tendency to disperse itself equally in the available air. D. Water vapor causes new homes to require house wrap.

C. Water vapor has a tendency to disperse itself equally in the available air.

The safe domestic water temperature in a home should NOT exceed how many degrees Fahrenheit? A. 145 B. 135 C. 115 D. 125

D. 125

When evaluating the operation of an AC system during the summer months, the temperature differential between the supply and renew air should typically be: A. 20-25 degrees Fahrenheit. B. 15-30 degrees Fahrenheit. C. 10-15 degrees Fahrenheit. D. 15-20 degrees Fahrenheit.

D. 15-20 degrees Fahrenheit

The modern MINIMUM size water service pipe to a residence is: A. 1 1/4 inch. B. 1 inch. C. 1/2 inch. D. 3/4 inch.

D. 3/4 inch.

A GFCI functions by sensing: A. An open neutral. B. A short circuit. C. An overcurrent condition. D. A current imbalance.

D. A current imbalance.

A sewage ejection pump in a vacant single-family home continues to operate intermittently for a few minutes after all the fixtures have been operated. This is MOST probably due to: A. Siphoning at a trap. B. A stuck float switch. C. A leaking outside hose connection. D. A leaking check valve.

D. A leaking check valve

The framing method that uses studs continuously from the sill to the roof is called: A. California framing. B. Platform framing. C. Post-and-beam construction. D. Balloon framing.

D. Balloon framing.

You see during your inspection that the air conditioning system has supply registers in each bedroom, but only one large return register is located in the center hallway. Your FIRST course of action would be to: A. Report that the A/C system will not work well. B. Report that the life of the A/C equipment will be reduced. C. Recommend to your client that return ducts be installed in each bedroom. D. Check to see if the bedroom doors are undercut at the bottom.

D. Check to see if the bedroom doors are undercut at the bottom

The MOST common cause of chimney flue liner deterioration is: A. High wind. B. Bad cement. C. Rust. D. Condensation.

D. Condensation.

Flexible gas connectors for gas dryers may NOT be: A. Made of stainless steel. B. Over three feet (3') in length. C. Six feet (6') in length. D. Coupled together.

D. Coupled together

While inspecting a crawl space, you should probe for decay if the ______ is dark in appearance. A. Bearing wall. B. Masonry wall. C. King joist. D. Floor joist.

D. Floor joist.

Which of the following should NEVER be installed in a concrete slab-on-grade floor? A. Waste pipe. B. Electrical conduit. C. Heat ducting. D. Gas piping.

D. Gas piping.

You observe long horizontal cracks in a CMU basement wall or foundation stem wall. The cause is MOST likely due to: A. Expansion of rusted reinforcing steel B. Lack of floor drains. C. Excessive loading on top of the wall. D. Highly expansive clay soils.

D. Highly expansive clay soils.

Bowing in a foundation wall is usually the result of: A. Spalling. B. Settlement. C. Vertical forces. D. Lateral forces.

D. Lateral forces.

EIFS is a siding material that: A. Can be installed on top of a masonry surface. B. Can be installed on top of a modified bitumen membrane. C. It used in commercial buildings only. D. Looks like stucco but lacks a wire mesh.

D. Looks like stucco but lacks a wire mesh

A drain waste vent installed on an individual fixture when there is no access to a conventional venting system is known as a(n): A. Inside vent. B. Roof vent. C. Outside vent. D. Mechanical vent.

D. Mechanical vent

Direct connections between potable water piping and sewer-connected wastes shall: A. Be protected by trap primers. B. Be provided with anti-siphon valves. C. Be protected by a check valve. D. Not exist under any condition.

D. Not exist under any condition

A drainage tile can be recognized BEST as a: A. Concrete splash-block set below the termination of a flat roof drain system to divert water away from the building B. Ceramic-tile washboard installed at a laundry sink to divert water into the sink. C. Curved clay-tile assembly installed along the headwall of a dormer in lieu of stepped flashing. D. Pipe set in gravel running continuously along the exterior of a building's foundation footings.

D. Pipe set in gravel running continuously along the exterior of a building's foundation footings

The purpose of collar ties is to: A. Prevent truss uplift and movement B. Prevent ceiling joists from twisting. C. Secure the trusses to prevent lateral collapse. D. Secure the roof framing to prevent spreading outward.

D. Secure the roof framing to prevent spreading outward.

All vertical joints of panel sheathing shall occur over: A. Window headers. B. Braced walls. C. Fire blocking. D. Studs.

D. Studs

Reversed polarity in a receptacle means: A. The grounded and equipment-grounding conductors are reversed B. The hot and equipment-grounding conductors are reversed. C. The receptacle is installed upside down. D. The hot and grounded conductors are reversed.

D. The hot and grounded conductors are reversed.

While inspecting the attic, you observe that the 2 x 4 webbing has been removed from two (2) adjacent manufactured roof trusses to enable the installation of the attic-mounted HVAC air-handler unit, in a single-family dwelling. Your report should state that: A. The trusses have been compromised, and this area should be monitored for signs of future structural failure. B. The trusses remain structurally sound, since the top chord and bottom chords have not been cut, and the roof sheathing will provide stability. C. No problems exist since only two (2) trusses have been modified, and they are adjacent.

D. The trusses are no longer structurally sound, and the best method of correction should be determined by a qualified engineer.

Home inspectors report receptacles with reversed polarity as potentially hazardous because: A. They trip ground fault circuit interrupter outlets. B. Single phase appliance motors will run backwards. C. They contribute to the overheating of the receptacle. D. They increase the shock likelihood at connected equipment.

D. They increase the shock likelihood at connected equipment.

What single factor causes the most problems with concrete at the time of installation? A. The wrong kind of sand is in the mix. B. Too much portland cement is in the mix. C. The concrete's thickness is insufficient. D. Too much water is added.

D. Too much water is added.

Under which of the following circumstances would it be acceptable to cut a truss? A. When cutting a member loaded in compression. B. When cutting a member loaded in tension. C. When installing a whole house fan and loads are transferred to adjacent trusses using headers. D. Upon approval of a structural engineer.

D. Upon approval of a structural engineer.

A sacrificial anode (also called an anti-corrosion rod) is found in: A. Sump pumps B. Galvanized supply systems. C. Pressure tanks. D. Water heaters.

D. Water heaters.

You complete your inspection and deliver the report to the client. The seller calls and asks what you found on the inspection. What is your response? A. You may discuss your findings if they are willing to fix any problems. B. Tell them that nothing serious was found and not to worry. C. Explain in detail what you found. D. You are not allowed to discuss your findings with them.

D. You are not allowed to discuss your findings with them.

In new construction, which of the following items would NOT be considered an electrical system defect? a. A #12 copper wire is connected to a 15 amp breaker. b. A #14 and a #12 wire are connected to the same terminal. c. An incandescent light fixture next to a closet shelf. d. Open knockouts are in an electrical panel.

a. A #12 copper wire is connected to a 15 amp breaker.

Fireplace flues must extend AT LEAST: a. Three feet above roof penetration and two feet above the highest point within 10 feet. b. Two feet above roof penetration and three feet above the highest point within 10 feet. c. Thirty inches above roof penetration and 24 inches above the highest point within eight feet. d. Three feet above roof penetration and three feet above the highest point within eight feet.

a. Three feet above roof penetration and two feet above the highest point within 10 feet.


संबंधित स्टडी सेट्स

BUS 2500 Chapter 03: Aplia Assignment

View Set

Week 10 Early childhood teaching as the pursuit of social justice

View Set

T cell-mediated immune responses

View Set

Chapter 30- Quiz #4 & Lecture Material

View Set

Chapter 6 Cisco Netacad study guide

View Set

NUR Pharmacology II Chapter 3: Toxic Effects of Drugs

View Set