NCIDQ - IDFX EXAM STUDY SET
On the illustration shown, place the hot spot marker in the location that would make it difficult to install the glazing assembly in a level position.
A shim space should be provided above the blocking. Shim spaces allow accurately built construction elements to fit within an opening that may not be perfectly square so it can be leveled. Shim spaces are also used to provide enough clearance to slide the element into the opening. The shaded area in the illustration indicates the margin of error for placing the hot spot marker. The interior window assembly, including the glazing and frame, would be assembled in the woodworking shop and brought to the job site as a unit. The blocking indicated below the window assembly would follow the line of the structural floor. If there are variations in the floor slab, or variations in the thickness of the blocking members, the top of this blocking will likely not be level. Placing the finished glazed portion directly on the blocking will skew the window assembly and put it out of level.
Which section of the International Interior Design Association's Code of Ethics requires continuing education?
A) "Responsibility to the Association and Interior Design Profession" (B) "Responsibility to the Client" (C) "Responsibility to Other Interior Designers and Colleagues" (D) "Responsibility to the Public" The answer is A. In the section "Responsibility to the Association and Interior Design Profession," the second canon states that professional and associate members shall seek to continually upgrade their professional knowledge and competency with respect to the interior design profession. There is a similar provision in the American Society of Interior Designers Code of Ethics. Options B, C, and D are parts of the International Interior Design Association's Code of Ethics, but they do not relate to continuing education.
The drawing shown is a sketch detail of a partial-height partition, which, in plan view, is part of a U-shaped enclosure that will be used to support and enclose a built-in stand-up work surface. What problem in construction does this detail indicate?
A) The partition will be unstable due to its height. (B) The 2× blocking will not provide sufficient support for the work surface. (C) The 5/4 oak trim will be difficult to install level. (D) There is not enough blocking to attach the wood base. The answer is C. There is no shim space indicated below the 5/4 oak trim, so the metal stud top runner would have to be installed perfectly level, which is difficult with rough framing, so it would be difficult to install the oak trim level. Because of the U-shaped configuration and the additional bracing that the work surface will provide to the vertical elements, the partition will have sufficient stability. The 2× blocking will provide sufficient backing for the attachment of any work surface support, such as a wood cleat, on the outside of the partition. The blocking shown inside the metal stud runner would provide sufficient support for the wood base. It could even be omitted if metal stud finishing screws are used to attach the base to the partition.
Which of the following are critical planning concerns for a commercial office space? (Choose the four that apply.)
A) adjacencies (B) daylighting (C) means of egress (E) efficiency factor
The cover sheet of a set of interior design construction drawings typically includes which of the following? (Choose the four that apply.)
A) building department data B) client's name and address C) index to drawings D) small-scale reference floor plan E) symbols used on the drawings F) zoning department information
Understanding a client's sustainability goals when looking for office space will help the interior designer.
A) determine if the project can be LEED certified (B) review the energy conservation of the mechanical system (C) determine if the building can be located in a brownfield site (D) focus site analyses on features that support sustainable design
Which method of veneer cut results in the straightest grain possible from MOST species of trees?
A) half-round slicing (B) quarter slicing (C) flat slicing (D) rotary slicing
Where on the construction drawings is it MOST appropriate to indicate that corridors conform to surface requirements for accessible routes?
A) on the detail sections (B) on the elevations (C) on the floor plans (D) in the schedules The answer is A. The types of surfaces used in corridors, as well as minor changes in elevation such as those that may occur at thresholds and changes of material, usually must meet surface requirements for accessibility. Conformance to these requirements is best shown on the construction drawings' detail sections.
The three parts of a means of egress include the
A) public way, exit, and exit access (B) public way, exit access, and corridor (C) exit access, exit, and exit discharge (D) exit, exit enclosure, and exit discharge
Changing a ceiling from gypsum wallboard to acoustic tile would MOST affect the room's
A) reverberation time (B) sound transmission (C) decibel loss (D) impact insulation class The answer is A. Changing from wallboard to acoustic tile affects the total absorption of a room and thereby changes the reverberation time.
The given plan drawing diagrammatically illustrates a built-in seating arrangement within a larger room. Which Gestalt principle informs how the overall shape would be perceived?
A) simplicity (B) grouping (C) continuity (D) closure The answer is D. In Gestalt psychology, closure is the human tendency to perceive an incomplete form as complete. This tendency is especially strong when the form suggests a simple shape such as a circle or square. The seating arrangement shown in the drawing strongly suggests a circle.
Window treatments should be specified in which MasterFormat division?
(A) 08 (B) 09 (C) 10 (D) 12
Drawings for a single floor in a high-rise building containing commercial office spaces would MOST likely use what form of sheet notation?
(A) 1, 2, 3, 4, and so on (B) A1, A2, A3, A4, and so on (C) A1.1, A1.2, A2.1, A2.2, and so on (D) A23.1, A23.2, A23.3, A23.4, and so on
What construction should be used to enclose a 1-hour-rated corridor?
(A) 1/2 in (13 mm) Type X gypsum wallboard on 35/8 in (92 mm) metal studs (B) 5/8 in (16 mm) Type X gypsum wallboard on 35/8 in (92 mm) metal studs (C) two layers of 1/2 in (13 mm) Type X gypsum wallboard on 21/2 in (64 mm) metal studs (D) 3/4 in (19 mm) gypsum wallboard on 35/8 in (92 mm) metal studs The answer is B. Although there are several ways to achieve a 1-hour rating, a single layer of 5/8 in (16 mm) Type X wallboard is the easiest and least expensive. The size of the studs is not a critical variable. Two layers of 1/2 in (13 mm) wallboard or the special 3/4 in (19 mm) rated wallboard would work, but these are more than is required. 1/2 in (13 mm) Type X wallboard can only achieve a 45-minute rating unless there is a veneer finish.
What type of resilient flooring would be the BEST choice for a commercial kitchen?
(A) 1/8 in (3 mm) commercial-grade vinyl tile (B) sheet vinyl (C) heavy-duty cork flooring (D) sheet rubber
In a fully sprinklered office building, how many sprinklers would be required in a room measuring 20 ft × 25 ft (6100 mm × 7620 mm)?
(A) 2 sprinklers (B) 3 sprinklers (C) 4 sprinklers (D) 6 sprinklers
An interior designer is selecting lamps for a residential living room. What color temperature should the designer select to create a warm, comfortable atmosphere?
(A) 2700K (B) 4300K (C) 6500K (D) 7500K The answer is A. Color temperature, which is measured in kelvins (K), is the temperature to which a black body radiator would have to be heated to produce that color. The lower the temperature, the "warmer" or redder the apparent color is. A color temperature of 2700K would be good to create a warm atmosphere. 4300K is the color of a cool white fluorescent lamp, while a color temperature of 6500K is the color of a daylight fluorescent. An overcast sky has a color temperature of about 7500K. All of these would have more of a blue or "cool" component.
A clothing store located on the ground floor contains 15,000 ft2 (1394 m2) of retail area, a 2000 ft2 (186 m2) space for fashion shows for a seated audience with small cocktail tables, and a 3000 ft2 (279 m2) stock room. Using the table shown, determine the total occupant load.
(A) 394 occupants (B) 434 occupants (C) 546 occupants (D) 660 occupants
A designer has determined that a client needs about 8000 ft2 (740 m2) of usable office space. The leasing agent for the building says that the rentable-usable ratio will be 1.25. Approximately how much area should the interior designer recommend that the client lease?
(A) 7500 ft2 (700 m2) (B) 10,000 ft2 (930 m2) (C) 10,700 ft2 (1000 m2) (D) 13,300 ft2 (1200 m2)
What types of lamps would be best to use in the display cases inside a jewelry store? (Choose the three that apply.)
(A) 75W PAR quartz (B) 150W R quartz (C) 14W T5 fluorescent (D) 90W MR-16 (E) 40W T10 (F) 20W LED The answer is C, D, and F. There are two aspects to consider for this application: size and color rendition. T5 fluorescent lamps can be specified with a high color temperature and are small enough to fit within most types of display cases. MR-16 lamps are relatively small and are tungsten-halogen lamps that would provide good color rendition and sparkle to jewelry. Light-emitting diode (LED) lamps would be the best choice because of their small size, cool operating temperature, and availability in a variety of color outputs. Both the 75W parabolic aluminized reflector (PAR) and 150W reflector (R) lamps would be too large to use in a display case and would generate a great deal of heat. A 40W T10 would be small enough to use in the display case, but its incandescent color rendition would be too warm for jewelry display.
Refer to the illustration, which shows a reflected ceiling plan for an office space (do not use the ceiling grid as a scale). What is the maximum spacing of the sprinkler heads indicated by A and B, in accordance with National Fire Protection Association (NFPA) 13 for light hazard occupancies?
(A) A = 4 ft, B = 8 ft (1220 mm, 2440 mm) (B) A = 5½ ft, B = 10 ft (1676 mm, 3048 mm) (C) A = 7½ ft, B = 15 ft (2286 mm, 4572 mm) (D) A = 10 ft, B = 17½ ft (3048 mm, 5334 mm)
Which of the following is a true statement about the difference between a programmatic concept and a design concept?
(A) A design concept specifies a particular way to achieve the programmatic concept.
Which standard is used for construction drawing sheet sizes for nongovernmental projects in the United States?
(A) ANSI (B) architectural (C) ASTM International (D) ISO The answer is B. Architectural and interior design drawings commonly use the architectural standard sizes, which begin with the size A, or 9 in × 12 in. Each sheet size larger is a multiple of that module; a B-size drawing, for example, is 12 in × 18 in, and a C-size drawing is 18 in × 24 in. The ANSI standard is based on a module of 8.5 in × 11 in and is not commonly used. ASTM International does not have a standard for architectural sheet sizes. The ISO standard is based on a module of 210 mm × 297 mm (8.3 in × 11.7 in), and is not used in the United States.
Which standard of the Business and Institutional Furniture Manufacturers Association (BIFMA) establishes criteria for the sustainability of furniture?
(A) ANSI/BIFMA e3 (B) ANSI/BIFMA G1 (C) ANSI/BIFMA M7.1 (D) ANSI/BIFMA/SOHO S6.5 The answer is A. ANSI/BIFMA e3, Furniture Sustainability Standard, provides performance criteria addressing environmental and social impacts throughout the supply chain of furniture, as well as product-based characteristics that impact the environment, health and wellness, and society. ANSI/BIFMA G1, Ergonomics Guideline for Furniture Used in Office Work Spaces Designed for Computer Use, provides guidelines for furniture intended for computer use by applying measurable principles and design requirements. ANSI/BIFMA M7.1, Testing for VOC Emissions from Office Furniture and Seating, provides manufacturers, specifiers, and users with a basis for characterizing the initial release of various airborne chemicals emitted from a furniture workstation and seating. ANSI/BIFMA/SOHO S6.5, Small Office/Home Office Furniture—Tests, provides performance and safety requirements for storage and desk furniture intended for use in the small office and home office.
What characterizes an isometric drawing?
(A) All axes are drawn to the same scale. (B) A three-dimensional view can easily be created by tilting a floor plan and extending vertical lines. (C) Lines of projection are perpendicular to the picture plane. (D) The view shows a cut approximately 5 ft (1525 mm) above the floor
Which of the following statements is true about seismic restraint for suspended acoustical ceilings in seismic design categories D, E, and F as defined in the International Building Code (IBC)?
(A) All ceiling-high partitions must be braced independently from the grid. (B) After determining the appropriate seismic design category, the interior designer can follow industry-standard detailing. (C) Main runners must be securely attached to the ceiling angles on opposite sides of a room. (D) Rigid compression struts are required at the grid intersections every 96 in (2.44 m) on center.
Which of the following organizations would be the BEST resource for an interior designer looking for independent, third-party information on the sustainability of architectural woodwork materials?
(A) Architectural Woodwork Institute (B) BuildingGreen (C) Forest Stewardship Council (D) U.S. Green Building Council The answer is B. BuildingGreen is an independent publisher offering unbiased information on sustainable building design and product information. It publishes Environmental Building News, a monthly newsletter, and the GreenSpec Directory, which lists product information for sustainable materials. BuildingGreen also offers various online tools on its website. The Architectural Woodwork Institute is the primary source for standards and information about woodwork in general, but has limited data on sustainability, and generally refers people to other sources for information on that subject. The Forest Stewardship Council oversees the development of standards for forest management principles; these standards cover all types of wood products, not specifically sustainable woodwork materials. The U.S. Green Building Council establishes criteria for the certification of sustainable buildings in its LEED rating systems. Although the rating systems contain criteria for the use of wood, they are not specifically concerned with woodwork.
What is the best source an interior designer could use to research the flammability and VOC ratings of several sofas the designer was considering specifying for a client?
(A) BIFMA standards (B) each manufacturer's local representative (C) the internet (D) local showrooms that sell the sofas
Which furniture test requires that an actual piece of furniture, or an accurate full-size mockup, be tested for flammability in a large furnace?
(A) CAL TB 116 (B) CAL TB 117 (C) CAL TB 129 (D) CAL TB 133 The answer is D. California Technical Bulletin (CAL TB) 133, similar to National Fire Protection Association (NFPA) 266, requires an actual sample of furniture, or an accurate mockup of it, be tested for flammability in a large furnace. CAL TB 116 and CAL TB 117 test the cigarette ignition resistance of upholstered furniture and only require samples of furniture upholstery components. CAL TB 129 tests the flammability of mattresses.
Which of the following are correct statements about corridors? (Choose the three that apply.)
(A) Corridors are part of the exit access. (B) Corridors are part of the exit. (C) Corridors must be used exclusively for egress. (D) Corridor construction must be fire rated. (E) Corridors are included in calculating travel distance. (F) Corridors must never have dead ends.
Which of the following statements are true about fire-rated door assemblies? (Choose the four that apply.)
(A) Either hinges or rated pivots may be used. (B) Glass area is limited based on rating. (C) Under some circumstances, a closer is not needed. (D) Doors must be the hollow metal type. (E) Ball bearing steel hinges are required. (F) Labeling is required for both the door and frame. The answer is A, B, E, and F. Either hinges or rated pivots may be used, glass area is limited based on rating, ball bearing steel hinges are required, and labeling is required for both the door and frame. Closers are always required at fire-rated door assemblies (protected openings). While doors with higher fire ratings (greater than 1 hour) are generally hollow metal, wood doors are available with fire ratings of less than 90 minutes.
An interior designer is looking for independent, third-party information specifically about a carpet's volatile organic compound (VOC) emissions. The BEST source would be the
(A) Green Label Plus program (B) GreenSpec Directory (C) Greenguard Environmental Institute (D) U.S. Green Building Council
For a project with an irregular plan and multiple wall finishes, what is the BEST method to describe finishes on the construction drawings?
(A) Identify all finishes on a schedule. (B) Develop a code number for each wall that references a finish schedule. (C) Provide elevations as necessary and use a standard finish schedule. (D) Use a finish plan with codes referenced to a legend and draw elevations when required. The answer is D. For a project with both an irregular plan (with angles, curves, and rooms with more than four walls) and multiple wall finishes on the same surface, a finish plan using lines extending the length of each finish along with a code is the best way to show where wall finishes start and stop. For walls with multiple wall finishes that may start and stop at various points above the floor, an elevation is the most accurate way to indicate finish layout. Using a schedule where finishes are referenced by room numbers is appropriate only for projects with simple finishes and on floor plans where each room has only four walls, and all are scheduled to receive the same type and color of finish. Using code numbers for each wall would result in an excessively large amount of numbers on the plan, many of which would be unnecessarily repetitious and still could not describe single walls with multiple finishes. While interior elevations would be useful, a standard finish schedule referenced to room numbers could not easily describe an irregular plan or communicate instructions for spaces where walls are to receive different finishes.
In a plenum, how can a fire be prevented from spreading horizontally?
(A) Install sprinkler systems. (B) Use fire-rated dividers. (C) Use fiberglass material. (D) Install fire dampers. The answer is B. In the space between a suspended ceiling and the structural floor above, fire-rated dividers are required if partitions do not extend through the plenum. Fire dampers are used in partitions and other fire-rated separations to allow fire-rated openings for duct work.
What are some of the advantages of continuing education for the interior designer? (Choose the four that apply.)
(A) It is a way to advance the designer's career. (B) It is a way to keep up to date with changes in the profession. (C) It is required by all states and Canadian provinces. (D) It is required for membership in many professional organizations. (E) It ensures all designers have a comparable level of knowledge. (F) It encourages professional organizations to develop learning opportunities.
. The partial floor plan given shows the subdivision of one side of an existing building into five offices with the architectural dimensions given on the outside of the building. Why is office #305 not dimensioned?
(A) It is the same width as office #304. (B) Dimension strings are left incomplete. (C) There may be a potential conflict with the existing overall dimension. (D) The dimensions can be calculated by subtraction from the existing architectural dimensions. The answer is C. When an existing space is subdivided, the designer is relying on information gathered through onsite measurement or record drawings. The existing overall dimension may or may not be exactly what is shown on the architectural drawings. By leaving what is known as an open dimension in the dimension string, the undimensioned space can accommodate any slight variation between the actual dimension and that shown on the architectural plans without the contractor raising questions. The open dimension should be the space that is the least important to have exactly as dimensioned. There is no information given on the plan that would allow the contractor to determine that an adjacent office should be the same size as another just by visual inspection (option A). Dimension strings are not necessarily left incomplete in all circumstances (option B). The contractor should not have to calculate dimensions, and in this case, the dimension of office #305 would not be accurate because the thickness of the existing exterior wall is not known.
When taking field measurements using a tape measure, what is the FASTEST way to verify accuracy?
(A) Measure each dimension twice from different directions. (B) Have two people take the same measurements and compare. (C) Use a laser-based device to compare with measurements taken manually. (D) Compare a string of dimensions with the overall dimension measurement. The answer is D. The fastest way is to take an overall dimension and compare it with the sum of a string of dimensions of the same elements. If the two values are close, the individual measurements are probably close enough to be used for planning and construction documents. If the values are divergent, the measurements should be taken a second time. While measuring twice and having two people take the same measurements may be good ways to check work, they are not the fastest methods for verifying the accuracy of the data. If a laser-based device is used to check measurements made by a tape measure, the laser should have been used in the first place.
When doing design work for remodeling toilet rooms to make them accessible, the designer finds that it is impossible to provide adequate clearance on one side of a door. What is the BEST course of action?
(A) Propose to the client that walls be demolished and replanned to provide the necessary clearances. (B) Apply to the building department for a variance because of the remodeling problem. (C) Specify a power-assisted door opener that meets accessibility standards and incorporate this into the design. (D) Suggest that a unisex toilet be built nearby that complies with all accessibility requirements.
An interior designer has just finished reviewing the plans for a large office suite when the building department states that the lighting budget has been exceeded. If the design is composed of 80% fluorescent lighting and 20% incandescent lighting, what is the BEST course of action to begin redesign?
(A) Reduce the number of luminaires by spacing them farther apart. (B) Substitute all incandescent lights with fluorescent lights. (C) Change to a task-ambient lighting system. (D) Investigate whether lamps with higher efficacies will bring the design within the budget. The answer is D. Option D allows everything but the lamps to be left unchanged. If this investigation did not bring the design within the budget, then the other options consistent with the design could be explored. Option A is not the best action because the illumination can easily be lowered below an acceptable level. Option B is a possibility and may ultimately be necessary, but other options should be explored first because the question asks what should be done to begin redesign. Option C is also a possibility, but the original design was developed for a reason and the first action should be to try to make that work.
What ratings are the MOST important in evaluating the acoustic quality of a floor and ceiling assembly?
(A) STC and NRC (B) IIC and STC (C) NRC and IIC (D) IIC and NC The answer is B. Impact isolation class (IIC) and sound transmission coefficient (STC) are both important ratings for evaluating transmission loss through a floor and ceiling assembly.
An interior designer is selecting luminaires and lamp sources to illuminate the waiting area of a medical clinic for which the furniture and finishes have been selected. In order to maintain the most accurate color rendition of the furniture and finishes, what is the best approach for selecting the lamps?
(A) Select those with the highest color rendering index (CRI). (B) Analyze the correlated color temperature (CCT) of the lamps. (C) Review the spectral energy distribution curves. (D) View the samples under each lamp being considered.
How can a drapery treatment be BEST changed to minimize its hazard during a fire?
(A) Shorten the length of the fabric. (B) Use an open-weave fabric. (C) Increase the amount of fabric. (D) Use a composite fabric.
Surface-mounted luminaires are MOST often used for which of the following reasons?
(A) Some side and uplighting is desired. (B) There is not enough space above the ceiling. (C) They are easier and less expensive to install. (D) They are used as a design feature.
What does the symbol shown in the illustration indicate?
(A) The area within the bubble is drawn at a larger scale elsewhere in the drawing set. (B) A section cut of the area in the bubble is shown on sheet A6 of the drawing set. (C) An elevation within the bubble is shown elsewhere at a different scale. (D) The portion within the bubble is described in more detail in the specifications. The answer is A. The symbol shown is a detail reference mark, which can be thought of as a magnifying glass. This symbol indicates that the portion of construction within the dashed bubble is drawn at a larger scale somewhere else. In this example, a larger-scale representation of the area is shown as detail number 12 on sheet A6 of the drawing set. This symbol indicates that the larger-scale drawing will have the same point of view; that is, if it encloses part of an elevation, the drawing referenced will still be in elevation view, just larger. It can be used on all types of drawings, including plans, elevations, and details. This is not a section-cut symbol. The symbol is not limited to just elevations and is typically used mostly for plans. This symbol does not refer to specifications.
While working on a large restaurant project, an interior designer and ASID member is given a set of drawings by the client for a public seating area that another designer developed for the client's previous restaurant. The interior designer is told to incorporate them into the current project and reduce their fee. What should the designer tell the client?
(A) The drawings will be included, and the fee that was originally built into their fee proposal for developing their own seating area plans will be reduced. (B) The drawings can be included, but the client will have to pay the original design fee for that portion of the project. (C) The drawings cannot be used because of ethical concerns, and the designer must develop new plans and drawings for the original set fee, but will include as much of the previous design as possible. (D) The drawings cannot directly be included in the designer's own set of documents because the designer did not prepare or supervise their development, but the designer could use them if the client paid for the extra time required to professionally review them. The answer is D. In the section "Responsibility to the Public," the American Society of Interior Designers (ASID) Code of Ethics prohibits the designer from sealing or signing drawings or other design documents, except where the designer or designer's firm has prepared, supervised, or professionally reviewed the documents. In this case the designer did not prepare them, but the Code of Ethics allows them to use the drawings if they review them. Options A and B are incorrect because the designer is not allowed to use the drawings directly regardless of whether the fee was reduced or remained the same. Option C is incorrect because they could use the drawings if they professionally reviewed them.
In which building type are fire-resistive construction requirements likely to be LEAST restrictive?
(A) Type I (B) Type II (C) Type III (D) Type IV
Which vinyl wall covering should be recommended for the family room in a single-family dwelling?
(A) Type I (B) Type II (C) Type III (D) Type IV The answer is A. Type I vinyl wall covering is the lightest weight of the three types and is appropriate for residential use. There is no Type IV wall covering.
In designing a room in which work will take place both at video display terminals and at standard work surfaces at each individual workstation, what approach to lighting design would be MOST appropriate?
(A) Use indirect ambient lighting, and use individual task lights at each workstation. (B) Locate downlights over work surfaces, and use indirect lighting fixtures over the terminals. (C) Use low-brightness troffers controlled by dimmers, and use task lighting on the work surfaces. (D) Specify a direct-indirect system that is locally controlled at each workstation. The answer is A. Any design with provided direct lighting, as in options B, C, and D, might result in reflections off the screens. Because the question does not state that the video display terminals are in known locations, an ambient/task light system is best.
Preliminary space planning shows that it is impossible to satisfy all the programmed adjacencies shown on the adjacency matrix, which has been approved by the client. What is the BEST course of action?
(A) Verify that the adjacencies require physical connection, and then review the problem with the client. (B) Satisfy as many adjacency connections as possible, and present this information to the client for review and approval. (C) Ask the client to downgrade the importance of the problematic adjacencies. (D) Develop several alternatives that come as close as possible to the requirements, and have the client select the one that best satisfies the program. The answer is A. Option A lets the client clarify the programming adjacencies and, if necessary, modify them so the designer can proceed with good information. If the client wants to see sketches to prove that the required adjacencies cannot be made to work, these are already available from the initial work on the problem. Options B and D are possible but require that the designer make guesses and do a lot of work before the client reviews the problem. Option C is risky because the problematic adjacencies may turn out to be the most important ones for the client, while the ones easily achieved may be less important.
An interior designer is creating a color-coding system for use in a housing facility for the elderly. Which of the following color combinations would be the MOST vivid and easily perceived?
(A) a bright color against a background of a noncomplementary color (B) complementary colors of high saturation (C) highly saturated warm or cool colors next to a neutral gray (D) the primary colors and white
A window covering that is made from fabric and is generally not intended to be opened is called
(A) a curtain (B) an Austrian shade (C) a vertical blind (D) drapery
Which design element could be used to make a ceiling appear lower?
(A) a dark, highly textured ceiling (B) strong horizontal lines on the walls (C) fine-grained patterns on the ceiling and dark walls (D) a light ceiling and textured walls
Consider the following diagram. The diagram shown is an example of
(A) a decision tree (B) an evaluation matrix (C) a materials hierarchy (D) a matrix chart The answer is B. The diagram is an example of an evaluation matrix. An evaluation matrix is a good tool for analyzing alternatives of a design by looking at specific aspects of the design and giving them ratings. Ratings can be shown graphically, as in this example, or with numbers; the numbers can then be totaled to see which alternative has the best rating. The alternative with the highest ratings may be deemed to be the best choice, and a decision can be made. The evaluation matrix can be fairly simple (as this example shows) or larger and more complex for complicated design issues. While the diagram is a matrix chart, given its grid of vertical and horizontal lines, that name doesn't describe its function for analysis and research. It also does not represent a hierarchy of materials. It is not in the form of a tree with branching alternatives, as a decision tree would be.
The BEST way to avoid fabric slippage over a cushion would be to specify
(A) a heavy fabric pulled tightly over the cushion (B) a high-density foam cushion with an interliner (C) rounded corners with welts (D) channeling
A designer is hired by a large corporation for its new headquarters. The designer estimates that the corporation needs approximately 73,000 ft2 of net space for its new facility. The corporation has leased three floors of 30,000 ft2 each. The designer needs to program the facility, assign specific areas for each space, and assist in assigning spaces more or less equally to the various floors. The best tool for the designer to use for this task would be
(A) a hierarchical list (B) an outline format (C) a process diagram (D) a spreadsheet The answer is D. To show a large number of individual spaces with attached floor areas and to make a summation for floor totals, a spreadsheet would be ideal. The spreadsheet's functions could accurately sum the areas, and the designer could also perform "what if" scenarios to move various spaces to each of the three floors to balance out the distribution of areas. An outline format would be cumbersome and time consuming, and would not easily show how spaces could be assigned to the three different floors. A process diagram is not used to show a summary of spaces. A hierarchical list could be used to show the assignment of individual rooms and spaces to larger departments, but would not have the flexibility of a spreadsheet.
A designer wants to give visual weight to a sofa. Which of the following color combinations would be the BEST choice for the sofa and the surrounding walls?
(A) a hue with a dark value for the sofa and a slightly lighter value for the walls (B) any light-colored hue for the sofa and a color with a dark value for the walls (C) a color with a warm hue and a dark value for the sofa and a much lighter color for the walls (D) a light, cool color for the sofa and a color of similar value and hue for the walls
The flame-spread rating of wood panel wainscoting must be
(A) a minimum of class A (B) class B if the wainscoting takes up more than 10% of the wall area (C) nothing, because it is not regulated (D) based on location and occupancy
A 216 pitch carpet has
(A) a pile height that is almost 1/4 in (6 mm) high (B) 8 surface yarns per inch (25 mm) (C) an equivalent gauge of 1/6 (D) a commercial-grade stitch rate
A designer has calculated the occupant load of a large, sprinklered hotel ballroom, and has determined that three exits are required from the space. The diagonal distance of the room is 160 ft (14.9 m). According to the International Building Code (IBC), two of the exits must be separated by at least one-third of the diagonal distance of the room. Where does the code require the third exit to be located?
(A) a reasonable distance from the others (B) a minimum of 80 ft (7.4 m) from the first two (C) as determined by the building official (D) at least one-half the diagonal distance from the first two
When a project includes both fixed partition walls and a full-height moveable partition system, on what plan should the moveable partition system be shown?
(A) a separate moveable partition plan (B) the construction floor plan (C) the furniture plan (D) both the floor and furniture plans The answer is B. A full-height moveable partition system should be shown on the construction floor plan, along with the fixed partition walls. This is because any type of full-height partitions will affect egress, as well as the HVAC system design, lighting, and sprinkler layout. A moveable partition plan is not necessary and is not a typical type of interior design drawing. A furniture plan would show cubicles and other moveable equipment but not moveable partitions.
An interior designer has been retained for a building project that is currently being planned by an architect. On the second floor of the building, slate flooring over a concrete subfloor is being used. What type of installation should ideally be designed for?
(A) a thick-set application using a cleavage membrane (B) a bonded thick-set installation (C) a 1/2 in (12 mm) layer of mortar with the stone dry-set on top (D) a standard thin-set installation
When selecting paint for a hospital, which of the following characteristics is MOST important?
(A) abrasion resistance (B) chemical resistance (C) flammability (D) VOC emissions The answer is D. Of the characteristics provided, volatile organic compound (VOC) emissions are the most important to consider when choosing interior paint for a hospital. Paints, varnishes, carpets, adhesives, and other household products can emit VOC gases, which have a variety of short- and long-term adverse health effects, such as headaches, fatigue, dizziness, or liver and kidney damage. In all indoor environments, but especially in healthcare facilities, products with low VOC emissions should be used. Where abrasion resistance is an important consideration, a finish other than paint should be used. Chemical resistant paint is a specially formulated finish that is unaffected by chemicals; for most hospitals, chemical staining is not an issue. Water-based paint is not flammable.
The most naturally fire-resistant untreated fabric is
(A) acrylic (B) cotton (C) nylon (D) wool
Which of the following are effective strategies for controlling moisture when detailing the area around a spa pool? (Choose the four that apply.)
(A) adhesives (B) drainage (C) slip resistance (D) flashing (E) tile selection (F) sealants The answer is B, D, E, and F. Drainage, flashing, tile selection, and sealants must be used correctly to prevent penetration of water to the substrates. Material selection must include impervious tile. Although the correct selection of adhesives and flooring materials with appropriate slip resistance ratings is important, these choices do not directly affect moisture control.
Adjacency requirements for the physical movement of goods in a manufacturing plant would BEST be illustrated with a(n)
(A) adjacency matrix (B) bubble diagram (C) flowchart (D) stacking diagram The answer is C. In a manufacturing plant, goods travel from one station to another during the process of fabrication. A flowchart would show the adjacencies as well as the steps in the process of manufacture. A bubble diagram would show the adjacencies but not necessarily the specific sequence of manufacture. Neither an adjacency matrix nor a stacking diagram would adequately illustrate the relationships between stations.
Which of the following would be the MOST important consideration in the design of ergonomically correct chairs for air traffic controllers?
(A) adjustability (B) firm cushions (C) lumbar support (D) tilt and swivel capability The answer is A. All the options are important considerations in designing ergonomically correct chairs. However, at most airports air traffic control is in operation around the clock, so the same chair will be used by different people at different times, and each person will be sitting in the chair for long stretches. Because of this, it is most important that the chair be easily adjustable to accommodate variations in body size.
For a member of the International Interior Design Association (IIDA), which action is a clear violation of the IIDA Code of Ethics?
(A) advertising in trade journals showing projects that the member firm has completed (B) including website photos of a project that was created by an employee while previously working for another firm (C) offering support to students of interior design, including information about the firm's projects (D) refusing to accept their client's instructions concerning copying a specific desired design feature the client saw in another project The answer is B. In the section "Responsibility to Other Interior Designers and Colleagues," a professional or an associate member may only take credit for work that was actually created by the member or the member's firm. Showing previous work by an employee that was performed while working at another firm is a clear violation of the IIDA Code of Ethics. Advertising is allowed as long as it is done without any form of false or misleading advertising or promotion. Members and associate members are encouraged to offer support, and information to students of interior design. Members may not accept instructions from their clients which knowingly involve plagiarism.
Thermal comfort for a person sitting in a classroom depends on...
(A) air temperature and humidity only (B) clothing type, air temperature, and air movement (C) air movement, convection, radiation, and conduction (D) air movement, air temperature, radiation, and humidity The answer is D. These are the four basic components to human thermal comfort: air movement, air temperature, radiation, and humidity. Although air temperature and humidity are two of the most critical aspects of comfort, they alone are not sufficient to describe it. Clothing can moderate the effects of air temperature, but it is not one of the basic components of comfort. Conduction is a very minor part of how the human body gains and loses heat.
The drawing shown occurs at the exterior wall of a high-rise building. The purpose of this detail is to
(A) allow for installation of a modular partition (B) provide for lateral movement of the building (C) provide for a finished end of the partition (D) give a tight seal to limit sound transmission
For a member of the American Society of Interior Designers (ASID), which action is a clear violation of ASID Code of Ethics?
(A) allowing the client to pay the designer with a part interest in the project instead of money (B) not disclosing that the interior designer has a financial interest in the building where the client's project will be located (C) as an employer, giving permission to an employee leaving the firm to take drawings on projects the employee worked on (D) sharing nonproprietary information about a project type with another allied professional
What type of drawing is shown in the illustration?
(A) alternatives diagram (B) parameter study (C) needs matrix (D) morphological chart The answer is D. A morphological chart is a graphical method used to explore various possible solutions to a design problem. As shown in the illustration, the various requirements of a design are listed across the top of the chart, with the number of possible solutions along the left column. These are combined in various ways to suggest a physical response to the issue at hand—in this case, how an entrance to a bar from a hotel lobby should be designed.
According to William Peña's book, Problem Seeking, all design problems can be stated in terms of form and which three other factors?
(A) analysis, synthesis, and function (B) function, economy, and time (C) goals, facts, and function (D) economy, time, and synthesis The answer is B. Design problems can be stated in terms of form, function, economy, and time. Each of these statements can be further broken down into more specific terms. For example, economy can be studied in terms of initial cost, operating cost, and life-cycle cost.
During preliminary planning for a day care center in a low-rise office building, the interior designer discovers that the zoning ordinance limits the area of such centers to about 20% less than the client's programmed needs. How could the interior designer best attempt to resolve the problem?
(A) apply for a conditional use permit (B) suggest the client apply for a variance (C) reduce the area planned to that allowed (D) appeal to the local planning commission The answer is B. A variance is a deviation from zoning regulations. The interior designer could assist the client in applying for a variance and present the case to the zoning board. In the case of a day care center requesting a relatively small size increase, it is likely that the hardship would be recognized and a variance granted. A conditional use permit is typically used to allow a nonconforming use in a zoning district and would not be the appropriate way to solve the problem. It is unlikely that the client would want to decrease the size of the planned center. The local planning commission would not be involved with this kind of issue.
What kind of scale is best used to measure the size of a drawn feature in feet and decimal fractions of a foot?
(A) architect's scale (B) engineer's scale (C) metric scale (D) graphic scale The answer is B. When a feature is measured with an engineer's scale, which uses scales such as 1″ = 40′ or 1″ = 100′, the measurement is read in feet, tenths of a foot, and hundredths of a foot. Civil engineers use scales of this type, or their CAD equivalent, to mark dimensions when drafting. When an architect's scale is used, the measurement and subsequent dimension is read in feet and inches, not feet and decimal fractions of a foot. A metric scale is similar to an engineer's scale in that it has 10 graduations per division, but the resulting dimensions are in millimeters, centimeters, or meters, not feet and decimal fractions of a foot. A metric scale is used when a project is planned and presented with SI units. A graphic (e.g., graphical, bar, linear, map) scale is a feature printed in the legend of a map or other drawing. Its resolution is usually coarse. Where smaller than whole divisions are indicated on a graphic scale, they are generally limited to 1/4, 1/2, and 3/4 graduations, so it would be difficult to measure the size of features in feet and decimal fractions of a foot.
What is the drawing shown most likely used for?
(A) as a starting point for design development (B) as a basis for construction documents (C) for the further development of a preliminary stacking diagram (D) to show the client a conceptual approach to a design
Which of the following activities can an interior designer engage in to fulfill their social responsibility as well as expand their professional development? (Choose the four that apply.)
(A) avoid conduct that would involve misrepresentation in professional activity (B) develop public service announcements promoting interior designers (C) join committees that develop or review industry standards (D) serve on design review boards in the location where the designer practices (E) participate in student critiques at the local interior design school (F) volunteer time to provide public education about the profession The answer is C, D, E, and F. Volunteering time for public education, serving on design review boards, helping to develop industry standards, and participating in student critiques are all excellent ways to give back to the community as well as to expand professional development. Option A is part of a code of ethics and would not serve as a way to satisfy social responsibility. Option B is not really a social responsibility.
When specifying the method by which two veneer pieces are to be applied, the MOST pleasing result is usually obtained with a
(A) balance match (B) book match (C) center match (D) slip match
Which type of plan is always needed to begin space planning in an existing building?
(A) base plan (B) circulation plan (C) exiting plan (D) reflected ceiling plan The answer is A. A base plan shows the layout of the existing building. It is always needed to begin the interior design space plan.
One basic theory about how inherent human motivation acts as a psychological influence on socialization and design is
(A) behavior setting theory (B) proxemics (C) McClelland's human motivation theory (D) Maslow's hierarchy of needs
The overall departmental relationships within a large company planning to occupy a multistory building would MOST likely be shown in a(n)...
(A) block diagram (B) adjacency matrix (C) stacking diagram (D) bubble diagram The answer is C. The company is large and will occupy a multistory building and therefore multiple floors. To show overall departmental relationships (rather than individual space relationships), a stacking diagram is used. Then, individual block diagrams or bubble diagrams are developed for each floor.
A designer is programming a large office installation that will occupy four floors in a high-rise building. In trying to determine which departments should be located on each floor, which of the following planning diagrams should the designer use?
(A) block plans (B) bubble diagrams (C) floor plan alternatives (D) a stacking diagram The answer is D. The most useful planning diagram in this situation is a stacking diagram, which is a drawing that shows the locations of major spaces or departments when a project occupies more than one floor of a multistory building. A stacking diagram based on departments or major groupings of spaces is usually worked out before each floor area is planned in detail. Bubble diagrams show space relationships graphically as outlined by adjacency matrices, and floor plan alternatives just show possible ways programmed spaces can be laid out; neither of these relates directly to how spaces are organized floor by floor. Block plans are developed after a concept diagram and before a final schematic space plan, so the planning of which department goes on which floor should already be done by the time a block plan is developed.
Which of the following must have AT LEAST a Class III (or C) fire rating?
(A) bookshelves (B) wainscoting (C) built-in base cabinets (D) door and window trim
Consider the following drawing. The drawing shown would typically be developed between the...
(A) bubble diagram and block diagram (B) bubble diagram and final schematic space plan (C) concept diagram and design development plan (D) concept diagram and final schematic space plan The answer is D. The drawing shows a block diagram, which is used as a transition-type diagram. The block diagram is typically developed after a concept diagram and before a final schematic space plan, which shows a hardline drawing of a floor plan. At this stage of a project's schematic planning process, a block diagram identifies adjacencies, relative sizes of spaces, and the location of circulation, without showing the exact positions of partitions, doors, fixtures, or other details. A concept diagram is developed based on a bubble diagram, and shows major influences and constraints on the design as well as the broad, overriding ideas the designer wants to incorporate into the project. A final schematic plan is developed from the block diagram and shows the exact positions of partitions, doors, plumbing fixtures, millwork, and other features that will later be developed into a design development plan.
Information concerning limitations on the use of a product can BEST be obtained from the
(A) building code official who inspects the product (B) specialty contractor who installs the product (C) manufacturer who makes the product (D) trade association representing the product type
Sharing common information in the same CAD file to create different types of drawings is known as
(A) building modeling (B) using the drawing modules standard (C) layering of drawings (D) using the U.S. National CAD Standard (NCS) The answer is C. Layering of drawings refers to the practice of placing different information on separate layers (or levels) in a CAD or BIM system. This allows individual layers to be shown or hidden as required to develop different types of drawings (floor plan, reflected ceiling plan, or furniture plan) using shared information from the same computer file. Building modeling simply refers to a three-dimensional representation of a structure. Drawing modules refers to how individual drawings are organized on a sheet within a grid system. The U.S. NCS is a collection of drawing standards, with layering being only one of those standards.
Dimensions on interior design floor plans are commonly drawn from the
(A) centerlines of partitions (B) finish faces of partitions (C) face of studs or structural walls (D) centerlines of structural walls and finish faces of partitions
Which type of seaming is the MOST appropriate for upholstered furniture in a smoking lounge?
(A) channeling (B) buttoning (C) railroading (D) welt cording The answer is C. When smoldering resistance, sometimes referred to as cigarette ignition resistance, is a high priority (such as in a smoking lounge), railroad seaming should be used. Railroading is the application of fabric to furniture so that there are no intermediate seam details where cigarettes could lodge and ignite. Dropped cigarettes can easily lodge and ignite in channeling, buttoning, and welt cording seams; therefore, they should not be used.
Consider the drawings shown. These kinds of drawings are known as...
(A) circulation components (B) parti diagrams (C) plan sketches (D) programmatic concepts The answer is B. A parti diagram is a rough drawing or diagram used early in the schematic design process to represent a design concept. The diagrams shown are concept alternatives for ways to design an entry to a bar area from a hotel lobby and are an example of a parti diagram. There is no such type of diagram as a circulation component. These diagrams also don't represent plan sketches, nor do they show programmatic concepts, which are typically text descriptions of a programmatic idea.
When specifying a specialty flooring material, the interior designer can obtain unbiased information on the hazards of a cleaning agent required for maintenance from the
(A) cleaning agent manufacturer (B) Environmental Protection Agency (EPA) (C) flooring manufacturer (D) safety data sheet
Furniture plans for commercial projects typically include which of the following? (Choose the four that apply.)
(A) code number for each piece of furniture (B) computers (C) desk lamp location (D) furniture location (E) partitions (F) telephone and data outlets
Which of the following terms represents the efficiency of a luminaire in distributing lamp light to room surfaces?
(A) coefficient of utilization (B) lamp lumen depreciation factor (C) lamp luminance (D) luminaire efficacy
It is essential that sample boards include
(A) color photographs of the furniture (B) a floor plan showing where each item will be used (C) actual samples of the materials (D) manufacturers' product data sheets
An accurate representation of materials can BEST be shown with a...
(A) computer rendering (B) full-size mockup (C) presentation model (D) study model The answer is B. A full-size mockup of an actual material would be the best way to represent the materials accurately.
What is one feature of inclusive design that differentiates it from accessibility and universal design?
(A) conforms to ADA requirements (B) considers cultural and social needs (C) does not include a broad range of diversity (D) responds to a broad range of users The answer is B. Inclusive design as it relates to architecture and interior design is the design of environments and products in such a way that a diverse variety of people can use them. It also considers cultural, social, and other needs that extend beyond those of the typical user. Inclusive design includes accessibility, but it extends design solutions not just to people with disabilities but to all users, accommodating a broad spectrum of diverse needs. Universal design seeks to make the same design features useful to a broad range of people, including people with disabilities. For example, using a lever handle on a door serves people with disabilities but also makes it easier for all people to use. Inclusive design differs, however, in that it may involve different solutions or different groups rather than just one solution to accommodate everyone.
The American Society of Interior Designers (ASID) is an example of a
(A) constituency-based organization (B) cause-based organization (C) knowledge-based organization (D) combination of constituency-based, cause-based, and knowledge-based organization
A designer is developing a space plan for a full floor tenant in a high-rise building. The designer needs to know which of the following to determine the maximum travel distance allowed by the IBC?
(A) construction type and height of the building (B) occupancy classification and whether the design involves an exit or exit access (C) occupancy classification and whether the building is sprinklered (D) construction type and whether the building is sprinklered
In starting a design project in a multi-use building, what information would an interior designer need to determine?
(A) construction type, adjacent occupancies, and sprinkler condition (B) construction type, fire-zone classification, and accessibility requirements (C) adjacent occupancies, sprinkler condition, and fire-zone classification (D) adjacent occupancies, fire-zone classification, and accessibility requirements
To confirm that a particular project meets material flammability requirements, an interior designer should
(A) contact each manufacturer whose materials are used (B) refer to state flammability regulations (C) contact the authority having jurisdiction (AHJ) (D) review the International Building Code (IBC) The answer is C. Although there are flammability requirements in the IBC and in state regulations, the jurisdiction in which the project is located may have additional requirements. For this reason, it is necessary to contact the authority having jurisdiction.
When developing adjacency requirements, the interior designer must consider
(A) contacts between people, transfer of objects, and electronic information (B) outside contacts with service people and visitors, as well as internal contacts (C) shared equipment and transfer of objects between people (D) frequency of required contacts between people and transfer of objects
Which of the following interior design services is normally performed during a project's contract documents phase?
(A) coordinating the consultant contracts (B) performing a code review (C) preparing furniture drawings (D) reviewing shop drawings
A designer wants to select a floor covering that is sustainable and resilient, and offers acoustical control. What flooring material BEST meets these criteria?
(A) cork (B) linoleum (C) vinyl tile (D) wood parquet The answer is A. Cork is a sustainable material, is soft underfoot, and provides the best acoustical control of the four options listed. Linoleum is a sustainable material and a resilient type of floor covering, but would not provide the best acoustical control of the four options. Vinyl tile is also resilient, but it is not a sustainable material. Wood parquet can be a sustainable material, but is hard underfoot and reflective of sound.
Important criteria for designing a lighting cove would include which of the following? (Choose the four that apply.)
(A) cost (B) design intent (C) ergonomics (D) aesthetics (E) support framing (F) lighting level
Which of the following should an interior designer FIRST take into account when designing a church's interior?
(A) cultural attitudes (B) proxemics (C) regionalism (D) symbolism
An interior designer is developing plans for the ceiling in a 25,000 ft2 (2323 m2) corporate office. The program calls for the office space to consist of 70% closed offices and rooms and 30% open office space. The program has also specified that the operation of the company changes frequently, requiring rearrangement of personnel teams and project organizations. Assuming a relocatable partition system is used, which type of ceiling system should the interior designer recommend to the client?
(A) custom track system (B) 60 in (1524 mm) lay-in acoustical grid (C) integrated ceiling system (D) narrow bar exposed T-bar system
In a 90,000 ft2 (8360 m2), single-story office building, what would be of greatest concern in space planning?
(A) dead-end corridors (B) corridor widths (C) horizontal exits (D) travel distances The answer is D. A 90,000 ft2 (8360 m2) building would be approximately 300 ft (91 m) on a side or about 250 ft (76 m) wide and 360 ft (110 m) long. The size combined with typical rectangular planning of corridors would create very long distances to exits.
An interior designer would MOST likely use anthropometric information to...
(A) design countertops for a public restroom (B) determine the percentage of children who would be comfortable on custom-designed benches in a puppet theater (C) develop the best position for multiple VDT screens in a stock trader's workstation (D) evaluate a new chair design that has just come on the market The answer is B. Anthropometrics is primarily concerned with measuring the size of the human body and developing dimensional ranges within which certain percentages of a given population fall. Such raw data would be directly useful for choosing the height, depth, and other aspects of the benches so that the greatest percentage of children would be comfortable seated on them. The other options relate more to ergonomics, or human interaction with the environment.
An interior designer typically develops color and material boards during the...
(A) design development phase only (B) schematic design phase only (C) programming and schematic design phases (D) schematic design and design development phases The answer is D. In most cases, the selection of finishes and furniture begins during the schematic design phase. The selection is then refined and finalized during the design development phase, before drawings and specifications are finalized in the construction document phase.
An interior designer talking with a client could justify the use of bright colors in an elderly care facility by referring to
(A) design theory (B) evidence from research (C) Gestalt psychology (D) historic precedent
Which of the following should the interior designer cite to support the inclusion of a large expanse of glass in a new office...
(A) design theory (B) factual evidence (C) Gestalt psychology (D) programmatic concepts The answer is B. The interior designer should cite factual evidence for this decision. The client is more likely to be persuaded by evidence of measurable benefits than by theories or philosophies. For example, studies conducted by the U.S. Department of Energy have found that natural light and visual access to the outside can increase the health, comfort, and productivity of building occupants. The term for the design approach that uses quantitative and qualitative research to support design decisions is evidence-based design. Design theory directs designs based on personal philosophies or beliefs. Gestalt psychology holds that humans perceive things as larger wholes, not as individual bits of stimulus. Programmatic concepts are statements about functional solutions to a client's performance requirements.
In the five-step programming process outlined by the book Problem Seeking, the fifth step is to state the problem. What is the order of the first four steps?
(A) determine needs, collect and analyze facts, uncover and test concepts, establish goals (B) collect and analyze facts, determine needs, establish goals, uncover and test concepts (C) uncover and test concepts, establish goals, determine needs, collect and analyze facts (D) establish goals, collect and analyze facts, uncover and test concepts, determine needs
A designer uses the principle of harmony in order to...
(A) develop visual consistency and equilibrium among individual elements (B) elicit compositional unity from different elements (C) establish two elements as more important than the others in a composition (D) provide variation in the elements of a composition The answer is B. Harmony is used to create a feeling of compositional unity from elements that are different from one another. Option A relates more to balance and repetition. Option C describes the principle of emphasis. Option D is incorrect because harmony is used to unify a composition rather than provide variation, even though variation is often part of a harmonious design.
A designer has developed a new workstation layout for a large corporate client. The workstation is unlike anything the client has used previously. The designer could BEST communicate the design and functionality of the workstation by
(A) developing large-scale plan views with details and large-scale elevations (B) having a full-scale mockup built that includes the actual workstation furniture being used (C) rendering a detailed perspective drawing with accompanying finish and material samples (D) commissioning a fully rendered, three-dimensional computer model that shows a "fly-through"
What type of lighting system would be the most appropriate for a call center where each employee works in front of a bank of computer monitors?
(A) direct-indirect (B) general diffuse (C) semi-indirect (D) indirect The answer is D. An indirect lighting system, where all the ambient light is directed upward and reflected off the ceiling, would provide the most uniform lighting with no hot spots, and would minimize glare. Any system that directs light downward has the potential for creating glare on a reflective surface, reducing visibility and causing eye strain. Options A, B, and C would all create this condition.
When considering the initial space planning of an accessible toilet room, which of the following design elements should be of MOST concern?
(A) door swing and toilet position (B) grab bar location and approach dimension (C) stall depth and grab bar location (D) door swing and approach dimension The answer is D. The size of accessible stalls, whether standard or end-of-row type, is fixed. Factors that could affect the total space required would be use of an in-swing door (which adds to the area required) and whether the design uses a side or front approach (latch side takes the least room). Refer to the following illustration. Grab bar locations and the toilet position relative to the stall are fixed and would not be of initial concern.
Division 05 of the MasterFormat system includes which of the following?
(A) doors (B) wall finishes (C) ornamental metal (D) architectural woodwork
A designer is developing a large, multilevel retail space with a variety of finishes, lighting, and fixture types. How can the designer BEST communicate the design to the client if cost is not a factor?
(A) draw several quick sketches of the space from different points of view (B) make a large-scale model with representations of the finishes applied (C) color a detailed perspective rendering as accurately as possible (D) commission a fully rendered 3-D computer model that can show a "fly-through"
An interior designer has received a construction cost estimate for an acoustical ceiling system. The area of the ceiling is 15,000 ft2 (1394 m2). The estimate is $6000 over the budget. The owner requests that the currently specified 2 ft × 2 ft (610 mm × 610 mm) grid with tegular tiles be replaced with a less expensive system while maintaining acoustical qualities and a similar aesthetic. The contractor has provided pricing for alternative ceiling systems as shown in the matrix. Based on this pricing information and knowledge of the acoustical properties of each of these types of assemblies, which alternate system should the interior designer recommend to the client?
(A) drywall with level 4 finish (B) standard tile in 2 ft × 2 ft (610 mm × 610 mm) narrow grid (C) standard tile in 2 ft × 2 ft (610 mm × 610 mm) standard T-bar (D) standard tile in 2 ft × 4 ft (610 mm × 1220 mm) narrow grid
Prior to determining the preferred location of luminaires, the interior designer is reviewing the mechanical engineer's HVAC layout, as shown in the partial plan in the illustration. If there is a conflict in position between a luminaire and ductwork, which ductwork would be the easiest and least expensive to relocate?
(A) duct A (B) duct B (C) duct C (D) duct D The answer is B. Duct B is a flexible duct and could be pushed out of the way or relocated easily along with the supply air diffuser to which it is attached. Duct A is a small duct for the exhaust fans in the janitor closet and the restrooms. Duct C is an 8 in × 10 in (203 mm × 254 mm) rigid duct and would be only moderately easy to relocate. Duct D is a larger rigid duct and would be difficult to move.
An interior designer is creating the design concept for a home. In addition to satisfying the program and meeting the specific needs of the client, the designer would typically be MOST responsive to the influence of
(A) economic conditions (B) cultural attitudes (C) regionalism (D) symbolism
Which of the following information about gypsum wallboard partitions should be part of a project's specifications, not its drawings?
(A) edge treatment (B) fastener spacing (C) stud depth (D) wallboard thickness
When coordinating the location of emergency warning systems consisting of audio and visual alarms as part of the reflected ceiling layout, the interior designer must coordinate with the
(A) electrical contractor (B) electrical engineer (C) fire protection engineer (D) mechanical engineer
An interior designer is providing complete space planning and furniture, fixtures, and equipment (FF&E) specification services for a large law firm. The location of electrical, telephone, and communication outlets for the space is BEST shown on the
(A) electrical plan (B) floor plan (C) furniture plan (D) power/communications plan The answer is D. In this case, it is best to use separate power/telephone plans and furniture plans. There would then be sufficient space to dimension and annotate the outlets on one plan and sufficient space for furniture locations and annotations on the furniture plan. The electrical plan (option A) is produced by the electrical engineer. It indicates the general locations of the outlets and shows the circuiting, conduit, and other technical information. An electrical plan does not typically include dimensions indicating where the receptacles are to be installed. For a large commercial project, the floor plan (option B) is not an appropriate place to show outlet locations because the floor plan will most likely be crowded with other information. While outlets are sometimes shown on a furniture plan (option C), for a client such as a large law firm, there would be numerous electrical, telephone, and communication outlets, as well as many furniture items. Trying to combine them and include all necessary information would result in a cluttered and difficult-to-read drawing.
The drawing shown in the illustration is an example of a(n)
(A) electrical plan (B) power plan (C) telephone/electrical plan (D) lighting plan
On a large hotel project, the interior designer is collaborating with the architect and other consultants. In reviewing preliminary drawings of the consultants to finalize the reflected ceiling plans, where should the designer look to find required fire detection and alarm locations?
(A) electrical plans (B) electrical drawings schedules (C) fire protection drawings (D) mechanical plans The answer is C. On a large project, there are separate fire protection drawings that show fire detection and alarms, as well as sprinkler plans. On a larger project, electrical plans generally do not show the fire detection and alarm locations, but they may show electrical service to them. Neither the schedules nor the mechanical plans show the fire detection and alarm locations.
When selecting a sofa for a residential family room, an interior designer is generally most concerned with which of the following? (Choose the four that apply.)
(A) fabric color (B) fabric type (C) cushion density (D) tufting pattern (E) flame-retardant composition (F) bacterial resistance The answer is A, B, C, and E. An interior designer who is choosing a sofa for a residential family room would be most concerned with the sofa's color, durability, cleanability, health implications, and flammability, all of which are influenced by the type of fabric selected. Cushion density affects the durability of the sofa. While bacterial resistance may be important in commercial installations, such as a hospital or doctor's office, it would be of minor concern in a residential setting. The type of flame retardant used can have health implications. In most cases, the tufting pattern in a residential family room does not directly affect any of these, so this would be of least concern to the designer.
What type of wall treatment would be appropriate for an office waiting room where durability and low cost are required?
(A) fabric wallcovering (B) thin stone tiles (C) vinyl wallcovering (D) wood veneer paneling
An interior designer is preparing drawings for a tenant build-out. Which of the following items are required by the International Building Code (IBC) when submitting for a building permit? (Choose the four that apply.)
(A) finish schedule or finish plan (B) architectural millwork details (C) all portions of the means of egress (D) custom furniture drawings (E) mechanical drawings (F) plan of interior space relative to entire floor or building
What is illustrated in the following partial drawing?
(A) floor finish plan (B) floor plan (C) lighting plan (D) reflected ceiling plan
Door fire ratings are typically given in the
(A) floor plan (B) door elevations (C) door schedule (D) specifications The answer is C. A schedule shows data in the rows and columns of a table. The door schedule includes a column in which to indicate what fire rating (in hours or minutes) is required for each door. If no rating is required, the space is left blank or filled with a dash or a zero.
Which type of drawing would typically include the symbol shown in the illustration?
(A) floor plan (B) reflected ceiling plan (C) elevation (D) section detail The answer is A. The symbol shown is an elevation reference mark and is used on floor plans to indicate (point to) a wall surface that is shown in elevation view elsewhere on the set of drawings. The bottom number is the sheet on which the elevation is drawn, and the top number is the sequential number on that sheet.
Which of the following normally shows the locations of exit signs?
(A) floor plan (B) reflected ceiling plan (C) life safety plan (D) fire protection plan
Smoke detector locations are shown on the
(A) floor plan only (B) reflected ceiling plan only (C) electrical plan only (D) reflected ceiling plan and electrical plan The answer is D. The electrical engineer is responsible for locating and circuiting smoke detectors, which are shown on the electrical plan. Smoke detectors are also shown on the interior designer's reflected ceiling plan so that the designer can coordinate them with other ceiling-mounted objects.
Which of the following corridor elements must be finalized with the floor plan during design development?
(A) floor surface material, turnaround space, and recesses for drinking fountains (B) corridor width, handrail projection, and exit sign locations (C) door swings, recesses for drinking fountains, and corridor width (D) location of visual alarms, turnaround space, and door swings The answer is C. During design development, the corridor configuration must be finalized to meet accessibility and code requirements. For this to happen, elements that can influence the width and layout of corridors must be finalized. These elements include protruding objects, door swings into the corridor, and recesses for anything that could interfere with the accessible route. While decisions regarding elements such as floor surfacing, exit sign locations, and the location of visual alarms may be important to the final construction drawings, these elements can be finalized in the construction drawing phase and are not required during design development.
Which test is MOST frequently used to evaluate carpet in the United States?
(A) flooring radiant panel test (B) Steiner tunnel test (C) methenamine pill test (D) methods of fire tests of building construction and materials
Which type of lighting would BEST enhance the appearance of a rough, plastered wall?
(A) fluorescent cove uplighting on all four sides of the room (B) decorative chandeliers near the wall (C) track lighting near the center of the room, aimed at the wall (D) recessed incandescents close to the wall
During space planning, the designer must locate a 36 in (915 mm) door leading from a corridor, where limited space is available, into another room. One option is to orient the corridor either perpendicular or parallel to the wall separating the corridor from the room and to swing the door in any direction. The door will have a latch only, with no closer. In order to provide for accessibility and minimize the width of the corridor, which of the following door orientations and approach directions would BEST meet the criteria?
(A) front approach, door swings into room (B) latch side approach, door swings into corridor (C) hinge side approach, door swings into room (D) front approach, door swings into corridor The answer is C. Looking at the required maneuvering clearances shown in Illustration for Solution 45, it is clear that the side approach with the door swinging into the room only requires a minimum of 42 in (1065 mm) (assuming the door has no closer). This would allow the use of a 44 in (1118 mm) minimum corridor. The front approach (door swings into room) and latch side approach (door swings into corridor) both require a minimum of 48 in (1220 mm). The front approach (door swings into corridor) would require a 60 in (1525 mm) corridor (a 36 in door plus 24 in of side clearance [915 mm plus 610 mm]).
The illustration shown represents a(n)
(A) function assignment (B) block diagram (C) departmental grouping (D) area diagram
Which of the following design principles would MOST appropriately govern the design of a hotel lobby?
(A) functionalism (B) proxemics (C) regionalism (D) symbolism The answer is B. Hotel lobbies provide a variety of functions for occupants who generally do not know one another. Therefore, proxemics—which deals with the spacing between people and the organization of those spaces—would be the most important design principle in the design of a hotel lobby. Using proxemics, the interior designer could determine the lobby's ideal front desk layout, waiting area configuration, furniture types and positions, and overall size. While the designer could also incorporate the principles of functionalism (e.g., simple, no extraneous decoration), regionalism (e.g., design reflecting local geographic area), and symbolism (e.g., using representative symbols) into the lobby decor, its overall design would best be governed by proxemics.
An interior designer has been hired by a client to design an office space. The client tells the designer to use discount chairs in order to save money. The designer initially agrees that the style and comfort level of the chairs will be compatible with the other furniture the designer will be selecting. On further investigation, however, the designer discovers that the chairs do not meet required VOC limits or flammability standards. What should the designer do?
(A) give the client documentation about the VOC and flammability standards, and tell the client that the designer cannot incorporate the chairs in the designs but will look for substitutes (B) suggest that the client try to find other chairs from the same discount source that will meet the VOC and flammability standards (C) accept use of the chairs (D) find substitute chairs as close as possible to the client's in cost but that meet the VOC and flammability standards
When reviewing flooring materials to determine which options meet life safety and accessibility standards for slip resistance, the interior designer should
(A) have the material tested (B) review the coefficient of friction (COF) (C) verify requirements of the Americans with Disabilities Act (ADA) (D) study pertinent ASTM International standards
During the preliminary planning phase, the diagram shown would be used to
(A) help the designer present data for adjacencies and area (B) show the client which programmed spaces belong in this zone (C) determine maximum floor areas on a building floor (D) begin the process for developing a stacking diagram
What type of cushioning would be BEST for a hospital waiting room?
(A) high-density foam (B) cotton batting (C) combustion-modified foam with a low ILD (D) low-density polyurethane The answer is A. High-density foam is used to create firm cushions. Firmer cushions prevent fabric coverings from stretching, thereby extending their useful life and appearance from the constant and heavy use of a hospital's waiting room. Cotton batting and low-density polyurethane are not as durable as high-density foam, and any material with a low indentation load deflection (ILD) implies a soft cushion (which is also much less durable than a firm cushion).
The construction assembly shown would be BEST for controlling which of the following kinds of acoustic situations?
(A) impact noise (B) transmission from room A to room B (C) transmission from room B to room A (D) mechanical vibration The answer is B. The assembly shown would not be the best for controlling impact noise (because it is a partition) or mechanical vibration, so options A and D are incorrect. Although the partition construction shown would be good for preventing sound transmission in both directions, it would be better from room A to room B. This is because noise transmission between two rooms is dependent on the transmission loss of the wall, the area of the wall, and the absorption of the surfaces in the receiving room.
Where are flame-spread ratings in a building MOST restrictive?
(A) in exit enclosures (B) on corridor floors (C) in access ways to exits (D) in enclosed spaces The answer is A. Exit enclosures, such as stairways and exit passageways
Which of the following would be the best source for looking at items just introduced to the furniture industry?
(A) industry magazine advertisements (B) local dealer showrooms (C) merchandise marts (D) trade shows The answer is D. Trades shows are typically events where new furniture items are introduced to the industry. They are excellent places to see actual examples of the furniture and to talk to the manufacturers about costs and technical specifications. Local dealer showrooms and merchandise marts usually lag a little behind trade shows in making new items accessible. Magazine advertisements may show previews of what will be shown at the trade shows, but they cannot take the place of seeing the real thing and being able to sit on it or touch it.
What type of system would be MOST appropriate in a large commercial remodeling project where a decorative acoustical ceiling and plenum access are required?
(A) integrated (B) linear metal strip (C) gypsum wallboard (D) concealed spline
A perspective drawing is the BEST type of drawing to use when presenting to a client because it
(A) is the quickest method of rendering space (B) most accurately shows vertical dimensions relative to the viewer (C) is most like the way space and objects are actually perceived (D) offers the widest choice of viewpoints
The primary advantage of an oblique drawing is that
(A) it shows the most realistic view of an object (B) all three axes are drawn at the same scale (C) existing orthographic drawings can be used as a starting point (D) it shows foreshortened lines and planes accurately
For the most durable wood finish, which of the following finish types should be specified?
(A) lacquer (B) penetrating oil (C) polyurethane (D) varnish
According to the affinity matrix shown, to which rooms must the kitchen be adjacent? (Choose the three that apply.)
(A) living room (D) laundry (E) dining room
A restaurant in an old building is undergoing remodeling. Which of the following existing building elements would have the MOST influence over the space plan for the proposed dining area?
(A) loadbearing columns and interior walls (B) building dimensions (C) plumbing fixtures (D) decorative millwork and ornate lighting fixtures
A demolition plan is required when the
(A) local authority having jurisdiction (AHJ) requires one (B) use of an additional line type for removed items would be too confusing (C) demolition involves partitions, doors, and cabinetry (D) mix of new construction and demolition is too complex for one drawing The answer is D. Demolition plans are required when the overlay of significant amounts of demolition interferes with the linework required for new construction. Local AHJs do not typically require a separate demolition plan. Using an additional line type, such as a dashed line, can be confusing if the plan is dense with linework, symbols, and notations. Whether demolition specifically involves partitions, doors, and cabinetry is not the important factor in determining if a separate plan is required.
A designer wants to emphasize one particular item in a client's retail store. Which of the following design features would BEST achieve this goal?
(A) locating the item on a main circulation axis and highlighting it (B) arranging a grouping of several of the items among single pieces of the other items (C) having an oversized model of the item made for display near the entrance (D) putting the item on a brightly colored pedestal in its usual place in the store
What existing condition in a building would MOST affect the cost of a new interior de
(A) location of exits (B) limited views and daylight (C) lack of a sprinkler system (D) remote location of an electrical closet
A new office suite is planned for the fifth floor of a building. Which of the following existing characteristics would MOST affect egress planning?
(A) location of stairs and presence of a sprinkler system (B) size of the existing building and fire rating of the existing corridors (C) area and shape of the fifth floor and location of stairs (D) location of the elevators and area of the fifth floor The answer is C. The location of the stairs is the primary factor in determining where and how the new space's exit access door or doors should be located. Exit access travel distance and the number and length of dead-end corridors should all be minimized, and the common path of egress travel should be considered. Furthermore, the area and shape of the existing floor plate could affect the exit access travel distance and, therefore, the layout of the new space. The presence of a sprinkler system could have an effect on egress planning, but a smaller one. The fire rating of the existing corridors and the location of the elevators will generally have little or no effect on where to locate the exit access doors
A library is being designed to occupy only one portion of a building, and a complete set of drawings is available for the building. What information would be the MOST important to obtain from the field survey?
(A) locations of structural elements (B) existing natural light sources (C) sources of noise within the building (D) locations and capacities of electrical power
Which of the following schedules are MOST likely to be found on a set of interior design drawings? (Choose the four that apply.)
(A) luminaire schedule (B) window schedule (C) door schedule (D) equipment schedule (E) millwork schedule (F) toilet accessory schedule
The interior designer is responsible for which of the following life safety considerations? (Choose the four that apply.)
(A) maintaining compartmentation according to the original architect's plans (B) planning for an exhaust system in the remodeled spaces (C) locating fire extinguishers as required by the local fire code (D) specifying gaskets and closers on fire doors (E) including fire protection of structural members according to the building type (F) locating fire dampers in new ductwork where fire partitions have been located The answer is A, C, D, and E. The interior designer is responsible for maintaining compartmentation, locating fire extinguishers, specifying gaskets and closers on fire doors, and including fire protection of structural members. The mechanical engineer is responsible for any exhaust system, if one is required. The mechanical engineer is also responsible for locating and specifying fire dampers, but the placement of these items is based on the location of any fire separations determined by the interior designer.
A designer can MOST improve the safety of a restaurant's design by
(A) making the exits highly visible (B) maintaining adequate spacing between tables (C) avoiding a level change of one or two steps (D) keeping the entrance to the kitchen away from seating The answer is C. While all the options are important in developing a safe restaurant design, a level change of just one or two steps is especially dangerous for any public space that will be used by people with a wide variety of physical abilities and limitations. Steps are also dangerous for servers carrying food.
In the illustration shown, the purpose of the device in the vertical partition section is to
(A) minimize reverberation (B) increase the sound absorption average (SAA) (C) reduce sound transmission (D) decrease potential impact noise
A residential design involves a bedroom, bath, and garage addition. At a minimum, the due diligence site investigation should include
(A) neighborhood character and zoning setbacks (B) zoning setbacks and septic capacities (C) heating system capacity and neighborhood traffic (D) zoning height limitations and street characteristics
A residential design in a rural area involves the addition of two bedrooms and two bathrooms. Which of the following should be the two GREATEST concerns during the home's due diligence investigation?
(A) neighborhood character and zoning setbacks (B) zoning setbacks and septic capacity (C) heating system capacity and septic capacity (D) zoning height limitations and heating system capacity The answer is C. Rural areas tend to use septic tank systems rather than sewer systems. Because the addition includes two bathrooms, the home's septic capacity should be a primary concern during the due diligence investigation. The addition of two bedrooms would also increase the home's heating requirements, so the heating system's capacity should also be a primary concern of the investigation. Although zoning setbacks, neighborhood character, and zoning heights should be reviewed in any due diligence investigation, they are less of a concern in rural areas than in cities because rural houses are typically much farther apart.
What is considered the primary canon of the Code of Ethics of both the American Society of Interior Designers and the International Interior Design Association?
(A) not to knowingly violate any law, regulation, or code (B) not to withhold any financial interest the designer may have in a project (C) to consider the health, safety, and welfare of the public (D) to perform services in the best interest of their client The answer is C. While all canons of the American Society of Interior Designers (ASID) and International Interior Design Association (IIDA) codes of ethics are important, the most important is to consider and protect the health, safety, and welfare of the public. An interior design member of ASID and IIDA should also always perform services in the best interest of the client; not violate any law, regulation, or code; and always disclose any financial or other interest the designer has in a project.
An interior designer's client wants to remodel a one-story office building into a restaurant and nightclub. Under the IBC, the life safety of the building that will require the MOST significant change is the
(A) number and location of smoke detectors (B) capacity of the sprinkler system (C) size and number of exits (D) addition of a smoke control system The answer is C. With a change of occupancy from an office that was originally a B occupancy designed using an occupant load of 100 ft2 (9.29 m2) per occupant to an assembly occupancy, A, with an occupant load of 5 ft2 (0.46 m2) (standing space for a nightclub) to 15 ft2 (1.39 m2) per occupant (for a restaurant with tables and chairs), the size of exits will have to be enlarged to accommodate more people. This could require major changes to the size and possibly the number and location of exits. While additional smoke detectors and their precise locations are important, they do not represent a significant change to the building. Both offices and restaurants are considered light hazard occupancies for the purpose of designing the sprinkler system, so the overall capacity would not be affected, just the exact location of sprinkler heads once the floor plan is established. For a one-story building of assembly occupancy, a smoke control system is not needed, as it is in a large high-rise building or a building with an atrium.
The BEST way to gather programming information from workers in a large office is through
(A) observation (B) questionnaires (C) interviews (D) benchmarks
The two MOST important factors in determining the number of exits required for a particular room or space are the
(A) occupancy and the distance from the room exit to the building exit (B) exit widths and the common path of egress travel (C) occupant load and the building size (D) occupancy and the occupant load
Which of the following pairs of building code requirements is MOST critical for the interior designer to know before starting the preliminary space planning?
(A) occupancy group and total floor area (B) number of exits and maximum distance to exits (C) allowable length of dead-end corridors and glazing requirements (D) occupant load and corridor construction requirements
Working under the IBC, a designer has calculated that a total exit width of 8 ft (2 m) is required from a store. What combination of door widths would meet most exiting requirements?
(A) one 36 in (915 mm) door remotely located from a pair of 34 in (864 mm) doors (B) a pair of 32 in (813 mm) doors remotely located from one 38 in (965 mm) door (C) three 34 in (864 mm) doors remotely located (D) three 36 in (915 mm) doors remotely located The answer is D. Options A, B, and C include doors that would provide less than a clear 32 in (813 mm) wide opening.
An occupant load calculation has shown that an office suite requires a total of 71 in (1804 mm) of egress width and two exit access doors. In order to meet all International Building Code (IBC) and accessibility requirements, what are the minimum door widths that should be used?
(A) one 36 in door and one 42 in door (914 mm and 1067 mm) (B) one 38 in door and one 34 in door (965 mm and 864 mm) (C) one 36 in door and one 44 in door (914 mm and 1118 mm) (D) two 36 in (914 mm) doors
Which of the following partition wall assemblies would be the least expensive to provide a 1-hour fire rating in a Type V-A building?
(A) one layer of ⅝ in (16 mm) Type X gypsum board on each side of wood studs (B) one layer of ⅝ in (16 mm) Type X gypsum board on each side of metal studs (C) two layers of ½ in (13 mm) gypsum board on each side of metal studs (D) two layers of ⅝ in (16 mm) Type X gypsum board on each side of wood studs
Interior designers can continue to develop their knowledge, serve their community, and enhance their professional development by
(A) participating in trade association work (B) volunteering in the community (C) serving on design review boards (D) teaching or mentoring young professionals
The method of constructing a fire-rated partition is typically indicated in the
(A) partition details (B) floor plan keynotes (C) partition schedule (D) contract specifications The answer is A. The partition details would indicate the method of constructing a fire-rated partition. The details include the framing, type, and thickness of gypsum wallboard or other construction, as well as how the partition's edges and other penetrations are sealed. Floor plan keynotes indicate only a partition's fire rating, not the actual method of constructing it. Partition schedules are seldom used, and in any case, they indicate only a partition's fire rating. Although contract specifications include important information about standards, quality of construction, and other aspects of fire-rated construction, they would not show a partition's actual construction method.
A client has asked a designer to create an intimate seating area for a hospital waiting room. Which of the following will be MOST important in achieving the client's goal?
(A) pattern (B) scale (C) texture (D) color
A college dormitory room shared by two people contains two identical sets of furnishings, symmetrically positioned. Which of the following psychological needs is this arrangement attempting to satisfy?
(A) personal space (B) territoriality (C) group interaction (D) personalization
The MOST appropriate time to determine the exact requirements for grab bars in a building's toilet rooms is during which project phase?
(A) programming (B) schematic design (C) design development (D) construction drawing development The answer is C. Only broad planning issues related to barrier-free design need to be made during the early design phases of programming and schematic design. While decisions about detailed items, like the locations of grab bars, can be made during the construction documents phase, it is better if they have been settled before the construction drawings are begun.
Exits are ALWAYS
(A) protected by fire-resistance-rated construction (B) limited in length (C) constructed as either corridors or stairways (D) required to have a 2-hour rating
For most planning problems, the MOST efficient type of circulation system is a...
(A) radial system (B) single-loaded corridor system (C) double-loaded corridor system (D) grid system The answer is C. Because a double-loaded corridor system serves rooms on both sides of it in a straight line, this is the most efficient option for most interiors. Radial and grid systems generally have much higher proportions of corridor to space served than double-loaded systems do.
During programming, what would the diagram shown be used for?
(A) recording notes from a client design meeting (B) showing an analysis of one of the facts of the program (C) exploring and presenting alternatives for design concepts (D) presenting part of a summary of a programmatic concept
On what type of drawing would the symbol shown in the illustration be used?
(A) reflected ceiling plan (B) egress plan (C) construction floor plan (D) mechanical floor plan The answer is C. The drawing shows a partition type indication with an accompanying flag note. It would be used on a construction floor plan to graphically show the construction of the partition and to differentiate it from adjacent partitions of another construction type. The flag note numbers are references to a legend that would give additional information about the construction, such as its fire rating, stud size, and finish.
The full extent of slab-to-slab partitions on a project is best shown on the
(A) reflected ceiling plan (B) interior elevations (C) wall section details (D) finish plan
Which of the following major areas is included in the ASID Code of Ethics but not in the IIDA Code of Ethics?
(A) responsibility to the public (B) responsibility to the profession (C) responsibility to the employer (D) responsibility to other interior designers and colleagues
What should be called out on cabinet drawings to ensure the BEST fit and appearance next to existing construction?
(A) reveals around all edges (B) spacers at cabinet backs (C) scribe pieces at cabinet edges (D) blocking, where necessary
An interior designer has drawn a floor plan of a large office space to a scale of ⅛ in = 1 ft 0 in (1:100) and determines that an enlarged floor plan of the toilet rooms needs to be included. What information should be shown on the enlarged floor plan that is not shown on the small-scale plans? (Choose the four that apply.)
(A) room names and numbers (B) dimensions to centerlines of fixtures (C) door swings of toilet partitions (D) dimensions to walls within the toilet rooms (E) dimensions of toilet partitions (F) toilet accessories with a key to a schedule
Which of the following generally include the MOST detailed information about doors? (Choose the four that apply.)
(A) schedules (B) floor plans (C) enlarged floor plans (D) room elevations (E) specifications (F) shop drawings
When completing a set of construction drawings for a restaurant kitchen, an interior designer should include an enlarged floor plan in order to
(A) show all kitchen equipment and reference notes (B) indicate detailed dimensions of the countertop layout (C) show all plumbing drains and hot and cold supply points (D) satisfy health department requirements for submitted drawings The answer is A. A commercial kitchen contains a complex collection of equipment, work surfaces, and plumbing. A standard ¼ in scale plan drawing probably would not be large enough to show all the equipment, dimensions, and annotation required, so a large-scale plan is typically necessary to communicate this information. Detailed dimensions of the countertop are not the only pieces of information required for a commercial kitchen. As with countertop layout, plumbing information (option C) is not the only information required and would be included on the mechanical engineer's drawings. Health department requirements do not require an enlarged floor plan as long as all the required information is shown. In some cases—for example, for a simple kitchen layout—this may be possible with the same scale drawing as the rest of the project.
An interior designer would minimize potential conflicts in the contract documents by doing which of the following? (Choose the four that apply.)
(A) showing dimensions on only the drawings, not in the specifications (B) having someone who has not worked on the project check the drawings before they are issued (C) writing the project specifications after the drawings are completed (D) ensuring that terminology in the specifications matches the drawings' terminology (E) developing a new drawing sheet organization method to match the needs of each project (F) using a master specification
Proxemics would be MOST helpful to a designer who is deciding on the
(A) size of a doctor's examination room (B) location of the office of the president within an office suite (C) size and shape of a conference table (D) type and spacing of seating in an audiovisual presentation room
An interior designer is developing a floor plan for a new tenant in an existing office space and will reuse a number of existing partitions to meet LEED reusability requirements. What notation should the interior designer use on the demolition plan to clearly distinguish partitions to be removed from partitions to be reused?
(A) solid lines for partitions being removed and dashed lines for partitions being reused (B) solid lines for partitions being removed and solid black fill for partitions being reused (C) dashed lines for partitions being removed and solid lines for partitions being reused (D) dashed lines for partitions being reused and solid black fill for partitions being removed
An interior designer is consulting with an architect for a new bariatric care facility. What does the interior designer need to be most concerned with? (Choose the four that apply.)
(A) space for health care workers around the bed (B) chairs and other seating (C) integration of bariatric seating with standard seating (D) door sizes (E) equipment storage (F) bedside amenities such as refrigerators
When considering the safety of smooth flooring materials, the interior designer should
(A) specify materials with a rough finish (B) require that the dynamic coefficient of friction have a value of 0.42 or greater (C) consider the values given by the DCOF AcuTest as well as other variables (D) use the coefficient of friction values and recommendations of ASTM C1028
In working with an electrical engineer on a project, what information would the designer MOST likely put on the interior design power plan?
(A) switch locations (B) dedicated outlets (C) conduit sizing (D) speaker locations The answer is B. The interior designer would not determine conduit size or put speaker locations on the power plan. This eliminates options C and D. Switch locations would be placed on the reflected ceiling plan.
Which of the following is the BEST choice for safety glazing in a hazardous location?
(A) tempered or laminated glass (B) tempered or wired glass (C) heat-strengthened glass or wired glass (D) laminated glass or wired glass
In developing a signage system for a health care clinic, the designer decides that the room identification signs should be mounted perpendicular to the wall near the door to each room. Which of the following are of greatest concern in the design work? (Choose the four that apply.)
(A) the color of the lettering and its background (B) that the amount the Braille lettering is raised above the surface (C) whether or not the width of the accessible route is reduced (D) the mounting height to the center of the sign (E) the use of the standard ADA font (F) whether or not the lettering is uppercase
The model number and color of a piece of furniture would commonly be found on
(A) the furniture plan (B) the furniture schedule only (C) the specifications only (D) either a furniture schedule or the specifications
When selecting interior partition finishes to meet flame-spread standards, the MOST important considerations are
(A) the occupancy group and the location in the building where the finishes will be used (B) whether or not the building has an automatic sprinkler system and the construction type (C) whether or not the partition is a fire barrier and the ratings of assemblies in the partition (D) the hourly rating of the partition on which the finish will be installed and the construction type The answer is A. Building codes limit flammability of finishes based on the occupancy of the building and whether the finishes are in an exit or not. A sprinkler system may allow a reduction in one flame-spread class rating but is not the overriding variable. Flame-spread requirements are also independent of the rating of the assembly on which the finishes are placed.
On a remodeling project with new construction, including partitions, a demolition plan is necessary when
(A) there is a complex mix of items to be removed and new construction (B) the authority having jurisdiction (AHJ) requires a separate demolition plan (C) the sustainability plan requires recycling and reuse of removed items (D) the contractor requests it in order to speed construction and avoid mistakes
Composite wood veneers can be used
(A) to improve the appearance of book matching (B) as a substitute for HPDL (C) as a "green" alternate to standard wood veneers (D) to increase the yield of veneer from a log
What is the purpose of construction element A in the following diagram of a wood floor?
(A) to minimize squeaking (B) to prevent chemicals from the subfloor from contaminating the wood (C) to act as a vapor barrier (D) to provide added resiliency
Which of the following are the two main factors used to determine whether a space must have more than one exit?
(A) travel distance and exit width (B) occupant load and occupancy (C) travel distance and occupant load (D) exit width and occupancy
Which carpet type allows a complex, custom-patterned carpet with varying pile heights?
(A) tufted (B) Axminster (C) Wilton (D) velvet The answer is C. Both the Axminster and Wilton processes allow for complex patterns, but only the Wilton process allows for varying pile heights.
What MOST affects the flammability of upholstery?
(A) type of chemical retardant used (B) cushioning and surface fabric (C) surface fabric and interliner (D) surface fabric The answer is B. Although chemical retardants and interliners are important considerations in upholstery flammability resistance, the combination of surface fabric and cushioning has the greatest effect.
When visiting a job site, the interior designer notices that a handrail appears to be out of place. When measuring it, the designer finds the top of the handrail to be 39½ in (1003 mm) above the nosing. In what direction and how far should the designer tell the contractor to move the handrail?
(A) up by ½ in (13 mm) (B) down by 1½ in (38 mm) (C) down by 3½ in (89 mm) (D) down by 6 in (152 mm)
Specifications can be made MOST concise by
(A) using reference standard specifications (B) avoiding the use of such words as "a," "the," and "all" (C) using phrases instead of complete sentences (D) using descriptive specifications
Which type of sink is BEST for barrier-free design?
(A) vanity (B) pedestal (C) wall hung (D) free standing
Interior spaces often need to be multifunctional or flexible. What are the three components of flexibility as a programmatic design concept?
(A) versatility, convertibility, and grouping (B) expandability, hierarchy, and flow (C) flow, hierarchy, and convertibility (D) convertibility, expandability, and versatility The answer is D. The three components of flexibility are convertibility, expandability, and versatility. Convertibility refers to a space's usefulness for different functions through the conversion of the space. Expandability refers to a space's ability to accommodate growth through expansion. Versatility refers to a space's ability to accommodate a variety of activities.
Which pair of performance tests should be specified for a custom-blended fabric that will be used in a recreation center's reception area?
(A) vertical ignition and Fade-Ometer (B) Wyzenbeek and Fade-Ometer (C) Taber and Wyzenbeek (D) indentation load deflection and Taber
What fabric would have the BEST appearance for the longest time when used in theater seating?
(A) vinyl (B) wool-nylon blend (C) acrylic-acetate blend (D) cotton-rayon blend
What are the MOST important design elements to incorporate into a hotel to provide safe egress for people with physical disabilities?
(A) visual alarms and audible alarms (B) visual alarms and flashing smoke detectors (C) audible alarms and large emergency lettering (D) audible alarms and tactile signage The answer is A. Emergency warning systems must provide both visual and audible alarms.
What is the MOST important criterion for lighting a fabric showroom?
(A) visual comfort probability (B) color rendering index (C) coefficient of utilization (D) apparent color temperature rating
Which of the following items does NFPA 701 relate to?
(A) wallcoverings (B) fabrics (C) draperies (D) floor coverings
In the drawing shown, where else would the capital letters under each elevation be found?
(A) with the frame details (B) in the specifications (C) on the door schedule (D) on the hardware schedule
In the detail shown, which dimension of the transition strip needs to be changed to meet accessibility requirements?
(A) ⅜ in (9.6 mm) (B) ¾ in (19 mm) (C) 1 in (25.4 mm) (D) 4 in (101.6 mm) The answer is D. The 4 in (101.6 mm) dimension needs to be changed. The ⅜ in (9.6 mm) carpet pile height leaves a vertical change in level of ⅝ in (15.9 mm), which must be accommodated with a ramp slope of 1:12. Either the height of the leading edge of the transition strip needs to be increased or the width of the sloped portion of the strip needs to be widened. Increasing the height of the leading edge of the transition strip to ⅝ in (15.9 mm) with a ⅜ in (9.6 mm) pile height results in an acceptable ¼ in (6.4 mm) vertical change of level from the top of the carpet to the strip, leaving a distance to the top of the wood floor of ⅜ in (9.6 mm). However, this is unrealistic because the carpet will be crushed under the weight of a wheelchair, effectively making the vertical change in level greater than ¼ in (6.4 mm). If the ⅜ in (9.6 mm) dimension remains unchanged in order to create a slope of 1:12, the width of the strip has to be widened from 4 in (101.6 mm) to 7½ in (190.5 mm) to create a 1:12 slope. ⅝ in (15.9 mm) × 12 = 7½ in (190.5 mm) The ¾ in (19 mm) dimension is horizontal and has nothing to do with accessibility. The 1 in (25.4 mm) dimension is fixed by the thickness of the wood floor. While the Americans with Disabilities Act (ADA) allows for a change of level up to ½ in (12.7 mm), with ¼ in (6.4 mm) being vertical and ¼ in (6.4 mm) having a slope of 1:2, this approach is not possible with the given thicknesses of the carpet and the wood floor.
Which of the diagrams is best suited for making a record of required space relationships just before initial space planning?
(B) Bubble Diagram The bubble diagram is better for showing relationships just before space planning. The relative sizes an positions of the bubbles indicate spatial relationships and sizes of the various spaces needed.
What is a block diagram?
A drawing that shows the various functions of a system by a series of blocks. These blocks do not include any detail, but instead indicate what happens in each block.
ANSI/BIFMA G1 IS?
Ergonomics Guideline for Furniture Used in Office Work Spaces Designed for Computer Use, provides guidelines for furniture intended for computer use by applying measurable principles and design requirements.
On the drawing shown, place the recommended dimensions for comfortable seating at a residential dining table in the boxes given. Some dimensions may not be required.
For comfortable dining, a 30 in (762 mm) width should be provided for each person, with an allowance of 18 in (457 mm) at the ends of the table for those diners. An 18 in (457 mm) depth should be allowed for each diner's place setting, with a 12 in to 18 in (305 mm to 457 mm) area in the center of the table. This gives a recommended table width of 48 in to 54 in (1220 mm to 1372 mm).
What is a flow diagram?
Is used as a scheduling chart or to show a flow of materials or another kind of process from one point to another
ANSI/BIFMA/SOHO S6.5 IS
Small Office/Home Office Furniture—Tests, provides performance and safety requirements for storage and desk furniture intended for use in the small office and home office.
ANSI/BIFMA M7.1 IS
Testing for VOC Emissions from Office Furniture and Seating, provides manufacturers, specifiers, and users with a basis for characterizing the initial release of various airborne chemicals emitted from a furniture workstation and seating.
Which seating group shown would be BEST for planning a waiting area to accommodate six people in a health clinic?
The answer is A. Because a waiting area is generally filled with strangers who prefer not to share the same sofa, a layout that provides individual seating is best, which eliminates options B and D. Option A is better than option C because it makes it easier for people to circulate to and from the chairs, and it increases the distance between people facing each other if all chairs are occupied.
Which of the diagrams shown might best represent a designer's concept planning for the operation and workflow of an urgent care facility?
The answer is B. Option B represents a centralized organization controlling or directing other groups. This would be appropriate for an urgent care facility where the entry/reception area is the starting point for directing patients to other parts of the facility. Option A represents a departmental organization with one person or department in the lead and other departments and groups organized below it. Option C is a linear organization where there is a starting point and subsequent activities occur in a strict sequence, which is not how an urgent care facility would operate. Option D is a network organization where activities may occur in many directions from any given starting point.
When reviewing the mechanical engineer's plan to identify the location of HVAC controls in the finished space, what symbol should the interior designer look for?
The answer is C. The thermostat is the primary HVAC system control in the finished space, and is represented by a circle with the letter T in it. The interior designer would be concerned with this to coordinate its position with an elevation of the interior space. Option A is not a standard mechanical symbol. Option B indicates a fire damper in a duct when used on a mechanical plan, and is also the symbol for a floor telephone outlet when used on an electrical or telephone plan. Option D is the symbol for a smoke detector in the ceiling.
When a fabric has been fire-retardant treated, it will
When a fabric has been fire-retardant treated, it will
The adjacency diagram shown is used for space planning for an executive group
Which personnel should be located closest to the VP of exploration? (Choose the three that apply.) (A) CEO (B) controller (C) traffic (D) treasurer (E) executive VP (F) VP of operations The answer is A, E, and F. In the adjacency diagram, the heavy lines and the number "1" indicate a primary relationship. The CEO, executive VP, and VP of operations are linked to the VP of exploration in this way in the diagram, so they should be located the closest.