SF-50 Electrical System

अब Quizwiz के साथ अपने होमवर्क और परीक्षाओं को एस करें!

How is power output regulated on Gen 2?

Thru the Alternator control unit (ACU)

How many MCU's do we have?

Two AFT and forward MCU

Where is BAT 1 Located?

Under the baggage floor

When would BAT 2 power the EMERGENCY bus?

When Gen 1 Gen 2 and BAT 1 fail

Can Gen 1 power all aircraft buses?

Yes

How many Volts/AMPS is BAT 2?

26.4 Volts 17 amp/hour

How many Volts/Amps is BAT 1

26.4 Volts 17 amp/hour

Generator 1 Volts/Amps

27.8 Volts 270 amp

How many Volts/Amps does Gen 2 have

28.7 Volts 72 Amp

Where is Gen 2 located

Accessory Gearbox

Where is generator 1 located

Accessory Gearbox

In normal operations what does gen 2 power?

Essential, Emergency bus and BAT 2

How is power from the generator regulated

Generator Control Unit (GCU)

Where is BAT 2 located?

In the left side of the nose cone

In normal operations what does generator 1 power

Main Bus and BAT 1

What are the different busses

Main, Essential and Emergency bus

Besides electrical power what does generator 1 have

Starter generator