Special Imaging Procedures

अब Quizwiz के साथ अपने होमवर्क और परीक्षाओं को एस करें!

The range of CT numbers or Hounsfield units varies from

-1000 to +3000

Modern pulsed CT scanners operate at:

120 kVp 1 to 5 msec pulses 1000 mA

The CT table is

Carbon graphite, rated for max weight and motor driven.

Who is credited with designing the first medical CT scanner in the 1970s?

Godfrey Hounsfield

The ______________ ___________________ is how well the detectors detect the incoming photon energy.

absorption efficiency

A ____________ artifact is caused by attenuation of the beam as it passes through the patient

beam hardening

The process of combining detector elements into various combinations in order to set slice thickness is called detector ____________.

binning

The ___________ ______________ is how well the detectors receive photons from the patient.

capture efficiency

Which of the following is best described as the body plane that divides the body vertically, front from back?

coronal

What is the term that best describes the IR in CT?

detector

In order for a CT x-ray photon to be measured, it must

enter the detector, be absorbed by the detector material, be converted to light and then electrical energy as a signal

What CT imaging characteristic allows for image differentiation among different tissue types?

excellent contrast resolution

The most recent generation of CT scanners use a ____ motion.

helical

This occurs when small structures lose detail in large volume areas.

partial volume effect

How is helical scan pitch best described?

ratio of the distance the table moves to the beam width during one revolution of tube travel

A _____________ artifact is caused by detector error.

ring

Which of the following is best described as the body plane that divides the body longitudinally, right from left?

sagittal

The CT console provide the radiographer access to:

software program, table movement, gentry

A ____________ artifact is caused by the presence of metal in the patient.

star

What is the primary advantage of CT over conventional digital radiography?

the ability to overcome the superimposition of structures

Computed tomography sections are acquired in the __________ plane.

transverse

Which of the following is best described as the body plane that divides the body into superior and inferior parts?

transverse

The gantry of the CT unit contains the

x-ray tube


संबंधित स्टडी सेट्स

chapter 6 art appreciation assessment

View Set

Pop Music Chapter 25 Study Guide

View Set

Technology: Application Software

View Set

The Catcher in the Rye by J.D. Salinger

View Set

Chapter 9 - Reviewing the basics

View Set

Chapter 9 Art QuizThe work of Hannah Höch is considered to be a part of what artistic styl

View Set

ES MODULE 2 chapter 15 BIODIVERSITY

View Set