Actives Quizes 25,31,32 Dr. Ford (For Final)
In a mid-rise office building, the elevator system may account for as much as
10% of total construction costs
As a rule, no bank of elevators should have more than
4 cars in a row
Approximately ______ of the energy expended in lifting a traction elevator car is returned to the system by regeneration when the car is lowered
75%
An acoustic detector will produce an alarm when
A specific range of frequencies is detected
Materials utilized as fire barriers within a building may also be useful for
Acoustic isolation of airborne sound
The three commonly encountered types of photoelectric infusion sensors are
Audible, Visual, and Tactile
In terms of building design, smoke differs from fire mainly because
Barriers to fire spread are not good barriers to smoke spread
A traction elevator machine room is generally located
Directly above the hoistway
An exit-control alarm would most likely be found in the following building type
Educational
Which of the following subsystems is less likely that the others to be controlled by a "Building automation system (BAC)
Fire Suppression
The three elements of fire triangle of needs are
Fuel, High Temperature, and oxygen
The term Intelligent building has been
Generally defined as a building that is productive and cost effective
The four stages of fire are
Incipient, smoldering, flame, and heat
The common elements of all signal systems are best described as
Initiator, processor, and indicator
Typical applications for hydraulic elevator systems would include
Low-rise passenger and freight services
A biometric access control system will
Measure and compare an uniquely personal physical attribute
NFPA stands for
National fire Protection Association
An ionization type fire detector will be used to sense
Products of combustion generated in the early stages of a fire
A "thyristor" is used to
Provide a means of speed control for AC and DC motors
Portable fire extinguishers would normally be
Selected and specified by the architect
The three basic parts of a fire alarm system are
Signal initiation, signal processing, and alarm indication
When considering property protection, the designer must address _________ very early in the schematic design process
Site access for fire-fighting equipment
Interval Refers to
The average time between car departures from an elevator lobby
Regeneration describes the process whereby
The elevator machine generates electricity when a car is lowered
The primary difference between instruction and access control system is
The first focuses on unauthorized persons and the second on authorized persons
Standpipe and hose systems are classified primarily according to
The type of person expected to use the system
A "passive infrared (PIR) presence detector" is desirable for areas
Where frequent motion is unavoidable
"premise wiring" is a term used to describe
a system of conduits or raceways that can accommodate signal system needs
energy and power in an elevator system are related as follows
energy is a function of power needs and operational patterns
Handling capacity refers to
the percentage of building population that can be carried by an elevator system