CH 39 Three-Phase Electricity & Power

Lakukan tugas rumah & ujian kamu dengan baik sekarang menggunakan Quizwiz!

characteristics of three-phase delta circuit

1. AC generators and/or loads connected in delta shape. 2. delta connections = line-to-line 3. no neutral connection 4. has phase voltage, line voltage.

3 sinusoidal voltage spacing

120 degrees apart due to location of windings.

impedance required to fully load a 3-phase voltage source.

3

terminal voltages of 3-phase AC GENERATOR produces

3 sinusoidal voltages of equal amplitude but different phase angles.

three-phase power: complex power delta load

S

3-phase wye connection line voltage

VL = measured between the lines.

wye connected source made by

connecting one ed of each on 3 windings with equal amplitudes that are separated by phase angle of 120 degrees.

delta-wye connection: convenient to

convert delta system to equivalent wye system and vice versa.

since power transfer for 3 phases = constant & not pulsating as for a single or 2 phase machine, 3 phase ....

vibrations are reduced = bearing life is extended

3-phase wye connection phase current

I p = current in single winding or phase.

three-phase power: apparent power

Q.

three-phase power: aka

complex power

three-phase power: components of power

complex, real, imaginary

3-phase wye connection line current

current in the lines

unless otherwise clarified, 3-phase voltages & currents are

effective values = RMS VALUES.

in 3-phase delta networks, line current = IL is always

greater than phase current IP.

delta-wye connection: have relationship with

impedance between balanced 3-phase delta-connected load & equivalent wye-connected load.

a six-conductor transmission line could be used to transmit power generated by 3 voltages, it is more efficient to

interconnect the windings & reduce # of conductors to 3 / 4.

for balanced circuits, the equations are used to find

line current from phase current.

what are all identical in a balanced system?

magnitude of voltages & line currents. real, complex, & reactive powers.

3-phase wye connection phase voltage

measured across a single winding or phase.

three-phase power: use of complex conjugates

necessary to keep complex power in the first and fourth quadrants bc apparent power is arbitrarily assigned a positive sign with inductive loads.

three-phase power: real power is never

negative or imaginary.

balanced systems analyzed on a

per-phase basis = one-line analyses.

3-phase wye connection: line-to-line voltages expressed in terms of

phase voltages.

3-phase system can produce magnetic field that

rotates in a specified direction = simplifying the design of electric motors.

single-phase alternating voltage

rotation of magnetic field thru the conductors of stationary coil.

power factor for each phase

same

3-phase wye connection phase sequence

what line to neutral voltages go through their maxima in regular order. Va reaches its peak before Vb. Vb peaks before Vc

3-phase wye connection line-to-neutral voltages differ from each other by

a third of an electrical cycle or 120 degrees.

3-phase wye connection balanced system, net current in neutral line =

0.

3-wire wye circuits have

1. 3 energized wires 2. more economical = eliminate neutral wire. 3. high-voltage transmission circuits.

4-wire wye circuits have

1. 3 energized wires and one neutral wire. 2. more flexible. 3. common distribution voltage circuits

using 3-phase power results in...

1. 3-phase currents that tend to cancel each other. 2. 3 phases sum to 0 in linear balanced load.

2 types of 3-phase wye sources

1. 4 wire wye circuits 2. 3 wire wye circuits.

benefit of 3-phase currents canceling each other?

1. allows size of neutral conductor to be reduced or eliminated.

2 methods used to interconnect the windings & reduce # of conductors to 3 / 4.

1. delta (mesh) connections 2. wye (start) connections

benefits of 3 phasor power.

1. smaller conductors. 2. more efficient than multiple single-phase systems proving same power. 3. uniform torque. 4. induction motors do not require additional starting windings or associated switches. 5. when rectified, has smoother waveform & less ripple to be filtered.

characteristics of three-phase delta circuit: phase voltage

Vp = voltage measured across a single winding or phase.

phase voltage

Vp or coil voltage, generated voltage from terminal voltages.

impedances in 3-phase system are BALANCED...

when they are identical in magnitude and angles.

characteristics of three-phase delta circuit: line voltage

VL = voltage measured between the lines.

3-phase wye connection. balanced circuits line-to-neutral voltage

VLN. equation Vl = sq rt 3 * Vp = sq rt 3 * VLN.

3-phase wye connection : ABC sequence

Va reaches its peak before Vb. Vb peaks before Vc

3-phase wye connection: CBA

ACB = negative sequence. obtained by rotating the field magnet in opposite direction, the phase of generated sinusoids is reversed.

3-phase wye connection which is greater line or phase voltage

V L > V P.

three-phase power: complex conjugate in equation

Z* of actual impedance. with 180 degrees phase change.

3-phase wye connection: line-to-line voltage calculated

apply KVL to generator circuit, use equations.

3-phase wye connection line and phase currents

are equal.

describe induced voltages changes polarity in magnetic field

as alternate polarities of magnetic field lines intercept conductors of stationary coil, induced voltage changes its polarity at the same speed as the rotating magnetic field.

three-phase power: components of power combine

as vectors to form complex power triangle.

three-phase power: equations are used to calculate complex power for

balanced loads.


Set pelajaran terkait

Elementary Statistics Homework, Quizzes, and Exams

View Set

Biology - Chapter 7-8: Photosynthesis

View Set

Chapter 23 Musculoskeletal System

View Set

STAT 201 - Canvas Content Quizzes 1-4

View Set

LAS RELACIONES INTERPERSONALES-TODO EN ESPAÑOL

View Set