Code

Lakukan tugas rumah & ujian kamu dengan baik sekarang menggunakan Quizwiz!

_______,_______,_______,________ The association that maintains and improves the quality and reliability of electrical products

(NEMA) national electrical manufactures association

Guest suit

A _________ is an accommodation with two or more contiguous rooms comprising a compartment that provides living,sleeping,sanitary,and storage facilities

1 in x 2 in 314.23 b ,2

A wood brace used for supporting a box for structural mounting shall have a cross section less than nominal___________

___________ are the main topic of the NEC beginnibf with NEC ARTICLE 90 INTRODUCTION, and ebding with NEC ARTICLE 830 network powered broad band systems

Articles

1 1/2 inches

Cable, box,be installed under corrugated sheet roof deck shall be supported so thrip of the cable raceway or box is not less than ______ from the lowest surface of the roof decking to the top of the cable raceway or box

There is _______ from the broad structure of the NEC

Chapters

Thread into the convolutions

Cut ends of FMC shall be trimmed or otherwise finished to remove tuff edges, except where fittings ____________

True

Direct buried conductors or cabled can be spliced or tapped without the use of splice boxs when the splice or tap is in accordance with 110.14 b t or f

_____________ explanatory material that follows specific NEC sections

Fine point note (FPN)

Cooking

Guest tons or guest suites provided with permanent provisions for ________ shall have receptacles outlets installed in accordance with all of the applicable requirements for a dwelling unit as specified in 210.52

Luminaries,cord and plug connected loads of 1440 va or less 210.6 a,1 and 2

In dwelling units the voltage between conductors that supply the terminals of ______ shall not exceed 120 volts

Concealed

Lmfc shall not be required to be secured or supported where fished between access points through ______ spaces in finished buildings or structures and supporting is impractical 350.30 A

______ _______ ______ ________ the publishers of the NEC THE NFPA Devils standees to minimize the possibility and effects of fire.

National fire protection association (NFPA)

______ ______ _____ ______ product safety certification laboratories that are responsible for testing and certifying electrical equipment

Nationally recognized testing laboratories (NRTL,s)

______ certain articles in the NEC are subdivided into parts. Parts have letter designations

PARTS

True

Raceways cable assemblies Box's ,cabinets and fittings shall be securely fastened in place. 300.11

True

Running threads shall not be used on IMC for connection at couplings 342.42 b

________ parts and articles are subdivided into sections. Sections have numeric designations that follow the article number and are preceded by period.

Sections

metal cable tray systems

Shall be permitted to support the wiring methods and equipment permitted to be used on other spaces. 300.22

Wet

The interior of underground raceways shall be considered a _____ location 300.5 b

20.25 cu in

The total volume occupied by two internal cable clamps , six 12 awg conductors, and a single- pole switch is ? 314.16 A table 314.16 b and 314.16 b -4

Multi wire branch circuit 210.4

The underground and grounded conductors of each _______ shall be grouped by wire ties or similar means in at least one location within the panel board or other point or origination.

Motel 220.61 c,2

There shall be no reduction in the size of the neutral of grounded conductor on _______ loads supplied from a 4 wire wye- connected, three phase system.

False

Thread less couplings and connectors used on threaded IMC end shall be listed for the purpose

That of 60 c conductors 320.80

Type ax cable installed in thermal insulation shall have conductors that are rated at 90 c. The ampacity of the cable in this application shall be based on

No 6

Utilization equipment weighing less than 6 ib can be supported to any box or plaster ring secured to a box provided the equities by id secured with at least two ______ or larger screws 314.27d

Supported

Wireing methods installed behind panels that allow access shall be _____ according to their applicable articles 300.40

Metal, nonmetallic, cable

_____ wiring methods can be installed in a cable trey 392.10

Angle

_______ connectors shall be used for concealed installations of LMFC 350.42

Angle

__________ connectors shall not be used for concealed installations of LMFC


Set pelajaran terkait

Final Exam: Questions and Answers

View Set

PT Lecture 21 - More Principles of Economic Justice

View Set

Principles of Business: 4.00_Understand Business Operations Management

View Set

Legal Environment of Business - Agency

View Set

Sear's Driving Book Chapter 10 Review

View Set

Repaso de Vocabulario 1 Spanish 3

View Set

Health and Skill-Related Components

View Set

Multiply Fractions by a Whole Number- Word Problems

View Set