HVAC Systems Quiz

Lakukan tugas rumah & ujian kamu dengan baik sekarang menggunakan Quizwiz!

PHIUS+ requires a separation distance of [?] between the ventilation intake and any known contamination source.

10 feet

For a very efficient air-source heat pump, heating COP (coefficient of performance) of [?] is a reasonable expectation.

3-4

Which of these choices does not provide overflow protection for bedrooms with closed interior doors while the ventilator is running?

A pressure switch in the supply register

What type efficiency rating would you expect to find for a gas/combustion-based space heating system?

AFUE

What is a potential problem with whole house fans?

Air leakage

Which of the following is a major difference between ASHRAE 62.2-2016 and PHIUS+ with regard to ventilation?

Assumptions about envelope air leakage rate

What common gas serves as a controlling variable for demand-controlled or advanced ventilation systems?

Carbon Dioxide

What part of an air-conditioning or heat pump system is outdoors?

Condenser

Which term best describes the ventilation system shown here?

Counterflow

How does a ceiling fan enhance summer comfort?

Creates moving air

Which function is an Energy Recovery Ventilator (ERV) not capable of?

Dehumidifying indoor air

What type of ventilation system would you choose for a building in a hot, humid climate?

Energy recovery ventilator (ERV)

Which of the following does a ducted mini-split system have that ductless system does not have?

Forced-air ducts

What are two key factors that affect the overall performance of a domestic hot water system?

Hot water heating efficiency, Hot water distribution efficiency

What are the two main components of the indoor unit of a ductless mini split system?

Indoor coil and fan

What is the minimum filter level required for fresh-air ventilation for PHIUS+ projects?

MERV 8

What building pressure difference with outdoors exist inside a building when a whole-house fan is operating

Negative pressure

What component does a heat pump have that an air conditioner does not?

Reversing valve

What function does this HRV perform that most HRVs sold do not perform?

Space conditioning

Evaporative coolers are best suited for [?] climates.

dry

An HRV is suitable for [?] climates.

heating‑dominated, dry


Set pelajaran terkait

Ch 8: Project Quality Management

View Set

Exercícios - Conferências ambientais: ENEM Geografia

View Set

NUR 110 Taylor Chapter 7 - Legal Dimensions of Nursing Practice

View Set

Elite Grammar Week 6 (Misused modifier)

View Set

Cell compounds and biological molecules ch. 2 & 3

View Set

Quiz #1 -Radiation Protection (Chapters 1 & 2)

View Set