_________ is/are often listed in order from the most likely to cause the symptom to the least likely to cause the symptom.

Faults

_________ windings in a DC motor include series windings and shunt windings.

Field

Common parameters associated with jogging include: Jog __________, Jog Accel, and Jog Decel.

Frequency

Two common types of variable speed AC drives are ___________ and vector drives.

General-Purpose

When using a megger to test insulation, one probe is connected to the winding and the other probe is connected to __________.

Ground

___________ is deep groves cut into the brush sliding face.

Hair lining

The DC voltage should only be inserted for a short period of time to prevent excessive ________ of the motor windings.

Heating

When all the external resistance is removed, the current in the rotor windings is limited by the amount of _____________ in the windings.

Inductive Reactance

Each winding should have about 2 to 8 ohms of resistance end to end, sometimes slightly higher. Resistance should be _________ to the frame and to the other windings.

Infinite

Field windings should have about 1 to 10 ohms of resistance end to end, sometimes slightly higher. Resistance should be ________ to the frame and to other windings.

Infinite

Stopping a motor by creating a stationary magnetic field in the stator is called DC __________ braking.

Injection

____________ are commonly used to test the winding resistance to indicate if a winding is open, shorted, or good.

Multimeter

Megger test voltage is based on the field voltage rating found on the motor ___________.

Nameplate

The first step to diagnose a DC motor failure is to _____________ using four of the five senses.

Observe

The first step to diagnose an AC motor failure is to ________ using the four of the five senses.

Observe

An electromagnetic fail-safe brake is engaged when the power is ______.

Off

A result of the reduced phase angle is that more useful ________ is supplied to the motor.

Power

Failure to lock out the ________ can result in possible injury, death, or test equipment damage.

Power

Speed control for a wound-rotor motor is only possible within the _________ of the external resistance.

Range

With ___________ braking, electricity is actually put back into the system

Regenerative

The _______ column lists the steps to take to correct the fault.

Remedy

If a capacitor is shorted, the ohmmeter will constantly display ____ ohms.

0

The insulation resistance to ground should be _____ megaohm per kilovolt, with a 1 megaohm minimum for any megger test.

1

The insulation resistance to ground should be _______ megohm(s) per kilovolt, with a 1 megohm minimum for any megger test.

1

A DC voltage that is at least _____% of the motor's peak voltage is required to stop the motor's rotation.

3

Determine the more suitable motor for the following scenario. A fan in a ventilation shaft is difficult to reach. It needs to be quiet and have a long life with minimal maintenance.

AC Motor

Determine the more suitable motor for the following scenario. A rotary saw blade requires a variable torque load from 9800 rpm down to 1750 rpm.

AC Motor

Determine the more suitable motor for the following scenario. An industrial blower requires a motor that uses little power at startup and is highly efficient.

AC Motor

The ___________ of an electromagnetic brake is connected to the motor shaft and can rotate freely when the brake is released.

Armature

Fifty-one percent of AC motor failures are the result of _________ damage.

Bearing

Applications where motors need to be halted require the use if motor _________ techniques.

Braking

The commutator film color should be a uniform light to dark _______.

Brown

The first step to test a(n) _________ is to inspect for a bulged case of leaks.

Capacitor

Troubleshooting ________ aid the troubleshooting process by providing a logical path to follow.

Charts

A phase winding to frame short usually trips __________ or opens fuses.

Circuit Breakers

The ____________ section of a general-purpose drive uses rectifiers to convert AC to DC.

Converter

Two common applications of wound-rotor motors are large hoists and _______ that are in fixed positions.

Cranes

The next step is to measure __________, voltage, and speed with the motor running.

Current

Determine the more suitable motor for the following scenario. A process control system needs a tank agitator that can run using battery power in the event of an emergency.

DC Motor

The pressure plate works with the clapper to prevent motor rotation when the brake is in the ____________ condition.

De-energized

DC motors failures can be mechanical or __________ in nature.

Electrical

Plugging should only be used in __________ and/or non-repetitive situations where rapid stopping is not often required.

Emergency

In many applications, ___________ controls are required to control a variable speed drive.

External

A wound-rotor motor can provide __________ starting torque per amp of current than a standard induction motor

Higher

DC motors are usually heavier and larger than 3-phase motors of equivalent ____________.

Horsepower

As the external resistance is reduced, the current in the motor windings _____________.

Increases

Electromagnetic brakes are load ____________.

Independent

The __________ parameter establishes the deceleration rate for a motor when a jog input is released.

Jog Decel

If the time delay of the off-delay timer is too ________, the motor will stop but then accelerate in the reverse direction.

Long

AC motor windings typically only have a few ohms of resistance, so set the meter to the _________ resistance range.

Lowest

DC motor windings typically only have a few ohms of resistance, so set the meter to the _________ resistance range.

Lowest

A(n) ________ or plugging switch can be used to plug a motor.

Magnetic-Not right

AC motors failures can be _________ or electrical in nature.

Mechanical

A(n) _________ is an instrument that uses high voltage to test wire insulation.

Megohmmeter

A(n) _____________ is an instrument that uses high voltage to test wire insulation.

Megohmmeter

The most common electrical instrument used to test a DC motor is a(n) _____________.

Multimeter

Some drives include ____________ that can be used to turn on external devices such as indicator light.

Output Relays

Variable frequency drives provide inputs for line power and ___________ for the motor.

Outputs

Dynamic braking is used on cranes, elevators, and locomotives when a condition called _________ can occur.

Overhauling

A(n) ___________ motor has to work harder than it was designed to work, which can lead to premature failure.

Overloaded

Connecting the full resistance of the rotor windings decrease the ____________ between the induced voltage and the rotor current.

Phase Angle

A three-phase AC induction motor can be reversed by swapping two of its ___________.

Phases

Common inputs to a variable frequency drive include manual inputs, __________ devices, potentiometers, and PLCs.

Pilot

A method of stopping a motor by momentarily reversing its direction is __________.

Plugging

Using a drum switch, speed switch, and off-delay timers are all different methods of ________ a motor.

Plugging

The ________ leads on a wound-rotor motor are labeled M1, M3, and M3.

Rotor

A speed controller connects to the _________ of a wound-rotor motor and controls the speed of the motor by adjusting the resistance of the rotor circuit.

Rotor Windings

DC motor field windings are subject to ________ in a winding, an open winding, and individual windings shorted to the motor frame or to other windings.

Shorts

A typical three-phase wound-rotor motor has ______ leads.

Six

A wound-rotor induction motor, also called a(n) __________motor, is an AC motor that provides AC variable speed control by varying the resistance of its rotors.

Slip-Ring

The user of a variable frequency drive can select what signal will provide the _________ command.

Speed

When jogging with a variable frequency drive, the direction and __________ of jogging can be controlled.

Speed

A speed switch is connected to the motor either directly to the ________ or via mechanical linkage.

Speed Switch

Reversing any two ________ leads will reverse the rotation of a wound-rotor motor.

Stator

A typical troubleshooting aid is organized by the _________ they are meant to test.

Symptoms

A typical troubleshooting aid is organized by the __________ they are meant to test.

Symptoms

Industry standard is to reverse the T1 and _____ leads.

T3

The _______ Method column tells the technician what tests to perform.

Test

The _________ column tells the technician what tests to perform.

Test Method

An automatic speed controller uses __________ and control relays to change the resistance.

Timers

Most motors are megger tested at _________ the nameplate rating.

Twice

A(n) ________ drive includes a feedback device to provide speed and direction feedback.

Vector

Reversing the rotor winding leads _______ reverse the rotation of a wound-rotor motor.

Will Not

Motor overloading causes high _______ current and high temperature which causes the winding insulation to fail.

Winding

The method for reversing the rotation of a(n) _____________ is the same as for reversing the rotation of a standard three-phase induction motor.

Wound-Rotor Motor

Determine the more suitable motor for the following scenario. A transformer coil winder needs a motor that provides constant torque between 500 and 1300 rpm and is capable of running 125% overload throughout the speed range.

DC Motor

The rotor windings of a wound-rotor motor are connected in either wye or ______ configuration on one end.

Delta

Plugging a motor using a timer is ____________ on the load.

Dependent

Depending on the drive, the inputs used to jog the motor may be _________ than the inputs used for standard control.

Different

One method of plugging a motor is to use a(n) _________ switch.

Drum

The rotation speed of a wound-rotor motor depends on the amount of ___________ connected to the rotor windings.

External Resistance

An example of a manual controller is a drum-type controller or a(n) ___________ controller.

Faceplate

________ is/are often listed in order from the most likely to cause the symptom to the least likely to cause the symptom.

Faults

The winding of a three-phase AC motor is tested by measuring the ________ with a multimeter.

Resistance

The external rotor circuit of a wound-rotor motor often consists of three high-wattage variable ________.

Resistors

To stop a motor, a(n) _________ on the brake pulls the clapper against the armature.

Spring

________ windings draw heavy current at startup. They are switched out of the power circuit by the centrifugal switch.

Start

One of the disadvantages of using an AC drive and motor instead of a DC drive and motor is that the AC motor cannot match the DC motor's __________ torque.

Starting