NACE CP 2 Concepts

Lakukan tugas rumah & ujian kamu dengan baik sekarang menggunakan Quizwiz!

The potential of a metal surface at a PH of 7 is -500 mV. What would be the potential of the same metal surface in a PH of 8?

-560 mV

Basic units of a rectifier

AC supply, circuit breaker, transformer, rectifying elements, meters, DC output terminals, fuses, surge protection

Metal surfaces in higher metal ion concentrations become more anodic or more cathodic?

Cathodic

Metal surfaces in higher oxygen concentrations become more anodic or more cathodic?

Cathodic

Metal surfaces in higher PH environments become more anodic or more cathodic?

Anodic

Metal surfaces in higher salt concentrations become more anodic or more cathodic?

Anodic

Metal surfaces in higher temperatures become more anodic or more cathodic?

Anodic

Anodic Interference

Current discharge, more negative structure potentials

Cathodic Interference

Current pickup, more positive structure potentials

When polarization increases, current and corrosion rate...

Decrease (when polarization is the control factor)

When movement in the electrodes and the electrolyte increases, polarization...

Decreases (and current increases)

When temperature increases, polarization...

Decreases (and current increases)

When there is an increase in cathodic metal ion concentration, polarization...

Decreases (and current increases)

What is used to prevent a reverse current at bonds

Diodes or reverse-current switches

Kirchoff's Law

E = IR

Nernst Equation

Expresses the exact electromotive force of a cell in terms of activities of products and reactants of the cell

Decrease in the potential difference between the anode and the cathode

Polarization

Faraday's law

Relates weight loss of metal in a corrosion cell with time and current

Corrosion can be expected at AC current densities at or above...

100 A/m^2

Voltages of ___ V AC are considered hazardous

15 V AC

Generally the lower the PH the _______ the CP current requirement

Greater

As oxidizers increase, the CP current requirement...

Increases

As temperature increases, the CP current requirement...

Increases

When there is an increase in anodic metal ion concentration, polarization...

Increases (and current decreases)

When current increases, polarization...

Increases (when current is the control factor)