Phoenix Hydraulics Power Point
Pumping Sprinkler Systems
1. Secure a water supply 2. Use 2 1/2" hose 3. Connect to all inlets 4. Reports of fire or active fire pump at 150 PSI 5. Nothing showing has two options: Pump at 100 PSI and wait for reports, Leave lines dry and wait for reports
0.434 PSI
A column of water 1' high exerts a pressure of ______ PSI at the bottom
50 psi
ALF ladder appliance value
100 PSI
All fog nozzles except TFT PSI?
Stream shaper
All smooth bore nozzles on master streams require a _________ ___________.
200
Any line with ______ GPM or greater flows must be shut down prior to repositioning the line
125
Automatic fog nozzles- Maximum ______ GPM with one firefighter on the line.
350
Automatic fog nozzles- Maximum ______ GPM with three firefighters on the line.
250
Automatic fog nozzles- Maximum ______ GPM with two firefighters on the line.
100 PSI
Automatic- Elkhart PSI?
75 PSI
Automatic- Fog Nozzle TFT (Task Force Tip) PSI?
90 psi
Baker Ladder appliance value
100
Both the fixed gallonage nozzles and adjustable gallonage nozzles have a set flow pressure of ______ PSI
250
Cellar nozzles produce ______ GPM
15 psi
Deck gun appliance value
NP
Desired or designed nozzle pressure for the nozzle being used
50 PSI plus the friction loss
Example: the forward pumper is pumping 200psi. How much PSI does the key pumper need to give.
((GPM x HS)/10) - 10) = FL/100'
Friction loss formula
((100 x 3(HS value for 1 3/4")/10)-10 ; (300/10)-10 ; 30-10=20 ; 20 x 1.5(150ft of hose) = 30
GPM = 100 ; HS = 1 3/4" ; 150ft
((125 x 4(HS value for 1 1/2") / 10) - 10 ; (500/10) - 10 ; 50 -10 = 40 ; 40 x 1.5 (150 feet) = 60 FL
GPM = 125 ; HS = 1 1/2" ; 150 ft
((150 x 3 (HS value for 1 3/4") / 10) - 10 ; (450/10) - 10 ; 45 - 10 = 35 ; 35 x 2 (200 ft of hose) = 70 FL
GPM = 150 ; HS = 1 3/4" ; 200 ft
((200x 1(HS value for 2 1/2") / 10) - 10 ; (200/10)-10 ; 20-10 = 10 ; 10 x 3 (300 ft) = 30 FL per 100 ft of hose
GPM = 200 ; HS = 2 1/2" ; 300ft
((200 x 2(HS value for 2") / 10) - 10 ; (400/10)-10 ; 40-10= 30 ; 30 x 2(200 feet of hose) = 60
GPM = 200 ; HS = 2" ; 200ft
((95 x 4(HS value for 1 1/2") / 10) - 10 ; (380/10)-10 ; 38-10= 28 ; 28 x 2(200 feet of hose) = 56 FL per 100' of hose
GPM = 95 ; HS = 1 1/2" ; 200ft
Intake to intake
How are dual pumping trucks connected?
70 PSI plus friction loss
If the forward pumper is pumping 220 PSI, what is the starting pressure for the key pumper?
50 or 75
Low Pressure Fog Nozzles operate at _____ or ______ PSI
1 3/8" , 1 1/2" , 1 3/4" , 2"
Most Common Stack Tip Sizes
Single
Multiple hand lines- Engine pressure is the highest ___________ line
95
Penetrating nozzles produce _____ GPM
(PSI drop x 100) / Static pressure = % drop
Percent method formula
25
Portable monitor multiple inlet ________ PSI
FL
Pressure lost as water travels through hose, fittings, appliances, piping, and adapters?
Head
Pressure produced as water moves downhill is ______ pressure.
Back
Pressure pushing back against the pump while trying to move water uphill is ______ pressure.
1/2 = 4/8 ; 4 + 2 = 6 ; 6 x 100 = 600 GPM
Rule of Eights Example: 1 1/2" tip
3/4 = 6/8 ; 6 + 2 = 8 ; 8 x 100 = 800 GPM
Rule of Eights Example: 1 3/4" Tip
1 8/8 ; 8 + 2 = 10 ; 10 x 100 = 1000 GPM
Rule of Eights Example: 2" Tip
50
Smooth bore on hand lines require ______ PSI
80
Smooth bore on master streams require ______ PSI
200, 250, 300
Solid stream nozzles on hand lines- GPM for 1", 1 1/8", and 1 1/4"
EP
The engine pressure or pump discharge pressure
70 psi
Tractor ladder appliance value
1. Fixed gallonage (flow) 2. Adjustable gallonage (flow) 3. Automatic
What are the three basic types of Fog Nozzles?
Fins or vanes
What are two other names for a stream shaper?
2 1/2" connection
What is the connection size for a cellar nozzle?
150
When you are the key pumper, if you're exceeding _____ psi you lose volume. This is your signal that there is a need for a second line.
350
_______ GPM is the maximum on any single hand line