Residential chapter 5

Lakukan tugas rumah & ujian kamu dengan baik sekarang menggunakan Quizwiz!

Three terminals

number of terminals :Three-way switch

Four terminals

number of terminals: Four-way switch

Two terminals

number of terminals: Single-pole switch

Travelers, source

A 4-way switch does not have "ON" and "OFF" markings. Four-way switches are connected to the _______between two 3-way switches. One 3-way switch is fed by the ______ ; the other 3-way switch is connected to the load.

tamper resistant

All 125-volt, 15- and 20-ampere receptacles in a dwelling are required to be______

2

Alternating current, general-use snap switches are UL-listed to control motors rated up to what horsepower?

Green hexagonal screw

Equipment grounding conductor screw color

More than two locations

From how many locations does four-way switching allow a lighting outlet to be controlled?

Single pole, 3-way, 4-way, double-pole, dimmer, occupancy sensor, and speed control. Available in snap, push, rocker, slider, rotary, electronic, w/ or w/out pilot lights

Name at least four kinds of lighting switches.

is not

On isolated ground receptacles, the metal yoke___ integrally bonded to the equipment grounding terminal of the receptacle.

are not

Phase conductors 6 AWG and smaller______ permitted to be re-identified as equipment ground conductors using green paint, tape, or other effective means.. po

Solid 14 AWG copper conductors

Screwless push-in terminals (i.e., back wiring holes) on receptacles are listed only for use with what type of branch-circuit conductor?

metal

Snap switches with nonmetallic yokes (straps) have a terminal for the equipment grounding conductor. Using this type of switch provides a means for grounding ______faceplates when nonmetallic boxes are used.

30 amperes

Specify the maximum overcurrent protection permitted for the following the circuit conductor sizes: 10 AWG copper

20 amperes

Specify the maximum overcurrent protection permitted for the following the circuit conductor sizes: 12 AWG copper

15 amperes

Specify the maximum overcurrent protection permitted for the following the circuit conductor sizes: 14 AWG copper

ungrounded

The NEC requires that switching be done only in ______conductors.

Neutral point

The common point on a wye-connected polyphase system or the mid-point on a single phase system is the _____

Switch loop

The conductors that run between a switched outlet and the switch controlling the outlet are called a(n) ______

white, gray, three continuous white stripes

The grounded (identified) conductor of 6 AWG or smaller must have an outer finish that is_____

grounded

The long slot on a 15-ampere, 125-volt, receptacle is the ______conductor.

all circuit conductors be run in the same raceway

To avoid inductive heating in metallic raceways, the NEC requires that______

Return conductor

When is a reidentified white conductor NOT permitted?

removed

When receptacles or switches have No. 6-32 screws secured to them with small pieces of cardboard, these pieces of cardboard must be ______when the wiring device is installed in a metal outlet box.

Silver, brass

When terminating a receptacle, the white (grounded) conductor is always connected to the _______ -colored terminal, and the phase (hot) conductor is always connected to the______ -colored terminal.

green with three white stripes

When using individual conductors in raceway, which insulation color is NOT permitted for the grounded conductor (neutral)?

For use with a tungsten filament lamp. They are designed to handle momentary high inrush currents

"T"-rated snap switches are intended for what application?

Where more than ne equipment grounding conductor enters a box, they are to be spliced with devices "suitable for use" no solder

Describe what NEC 250.148 requires to maintain the continuity of the equipment grounding path.

Silver-colored screw

Grounded (white) conductor screw color

Brass-colored screw

Hot (phase) conductor screw color

Use nonmetallic faceplates or provide GFCI protection

In older existing installations, where an equipment ground does not exist in a metal switch box that is located within reach of a conductive floor such as tile or cement, NEC 404.9(B) requires the use of what kind of faceplate?


Set pelajaran terkait

Chapter 17: From Gene to Protein

View Set

Lesson 20 (AB) - Reproductive and Urinary Systems *NSFW*

View Set

Chapter 46: Nursing Care of the Child With an Alteration in Cellular Regulation/Hematologic or Neoplastic Disorder

View Set

MAR4802-Lesson 14: Engaging Consumers and Communicating Customer Value - Integrated Marketing Communication Strategy

View Set