Sterile items should be stored at least ___________ inches below the sprinkler heads. a. 8 b. 18 c. 12 d. 15

18

Before an item can be placed in a low temperature sterilization processing system they must be a. heated b. filled with air c. sterilized d. cleaned

cleaned

The shelving system of choice for the sterile storage area is a. closed b. semi-closed c. open d. track

closed

Three of the main phases of the terminal steam sterilizer cycle are a. gravity, exposure and exhaust. b. exposure, exhaust and dry c. conditioning, exposure, and exhaust.

conditioning, exposure, and exhaust

Steam sterilization is most commonly used method of sterilization used in healthcare because a. cycles are fast and inexpensive. b. it is versatile; the temperature can be adjusted to sterilize heat sensitive items. c. there is no need to run biological tests for steam sterilization. d. chemical indicators are optional in steam sterilization.

cycles are fast and inexpensive.

Aluminum foil is an approved packaging material for use in ethylene oxide sterilizers. a. true b. false

false

An extended aeration cycle is required for items sterilized in the ozone sterilization process. a. true b. false

false

Because shelf life is event related, stock rotation is no longer necessary. a. true b. false

false

Documentation is not required for items that are immediate use steam sterilized. a. true b. false

false

Ethylene oxide, hydrogen peroxide and ozone sterilization can all use the same packaging materials. a. true b. false

false

Gravity steam sterilizers use a pump or water injector to remove air from the chamber. a. true b. false

false

Hydrogen peroxide is an effective sterilizing agent for linens and gauze sponges. a. true b. false

false

Hydrogen peroxide kills microorganisms by a process called oxidation. a. true b. false

false

Immediate use steam sterilization is the process to sterilize trays for future use. a. true b. false

false

Immediate use steam sterilization was developed to process items when the facility does not have enough instruments to perform the surgery. a. true b. false

false

Lumens should be moist when using hydrogen peroxide as a sterilizing agent. a. true b. false

false

Personal protective equipment is not required when cleaning items for immediate use steam sterilization. a. true b. false

false

Steam flush pressure pulse sterilizers are a type of gravity sterilizers. a. true b. false

false

Temperature and humidity levels in the sterile storage area should be checked and recorded at least weekly. a. true b. false

false

Temperatures in a sterile storage area should be 55 degrees to 60 degrees Fahrenheit. a. true b. false

false

The sterilization method of choice for single-use items is immediate use steam sterilization. a. true b. false

false

When combining loads, hard goods should be placed on the top shelves to allow for more efficient removal of the condensate. a. true b. false

false

When sterilizing items at point of use an abbreviated cleaning procedure may be used due to the urgent need for the instruments. a. true b. false

false

Woven reusable fabrics are the packaging products of choice for ozone sterilization. a. true b. false

false

Woven reusable fabrics are the packaging products of choice for ozone sterilization. a. true b. false

false

it is recommended to use immediate use steam sterilization to sterilize instruments contaminated with CJD after the procedure has been completed. a. true b. false

false

lumens should be moist when sterilized using hydrogen peroxide as a sterilization agent. a. true b. false

false

Sterile storage areas should a. have positive airflow and at least 10 air exchanges per hour. b. have positive airflow and at least four air exchanges per hour. c. have negative airflow and at least four air exchanges per hour.

have positive airflow and at least four air exchanges per hour.

The most common reason steam sterilization failure is a. lack of steam contact with the instruments. b. temperature in the sterilizer chamber . c. time of the conditioning phase. d. dry steam.

lack of steam contact with the instruments.

What exposure is monitoring is required for all personnel using a hydrogen peroxide sterilizer? a. no monitoring is required b. daily c. semi annually d. monthly

no monitoring is required

Exposure monitoring is _________ for all personnel using a hydrogen peroxide sterilizer. a. not required b. required daily c. required semi-annually

not required

Heavy items should be placed a. on the shelf first. b. on the bottom shelf. c. on the middle shelves. d. on the lower shelves.

on the middle shelves.

Items to be disinfected or sterilized at point of use must be a. properly cleaned per manufacturer's instructions for Use. b. semi-critical devices. c. non-critical devices

properly cleaned per manufacturer's instructions for Use.

Outside shipping containers a. should be removed prior to placing the items in storage. b. may be stored in the sterile storage area as long as they are not stored near the in house sterilized items. c. make good storage containers to help keep items from falling from the shelves. d. all the above.

should be removed prior to placing the items in storage.

Implantable devices a. should be immediate use sterilized in the extended cycles. b. should only be sterilized using ethylene oxide. c. should not be immediately use steam sterilized unless there is a tracking system in the place to trace the item to a patient. d. should discarded if not used.

should not be immediately use steam sterilized unless there is a tracking system in the place to trace the item to a patient.

The bottom shelf of any sterile storage system should be a. solid and 8 to 10 inches from the floor. b. solid and 2 to 4 inches from the floor. c. wire and 8 to 10 inches from the floor.

solid and 8 to 10 inches from the floor.

One common cause of clogged drain screen is a. tape b. wrapper particles. c. poor steam quality. d. a malfunctioning baffle plate.

tape

The higher the bioburden on an object a. the more difficult it will be to sterilize. b. the less time it will take to sterilize. c. the more biological tests will be needed in the load.

the more difficult it will be to sterilize.

The coolest place in the steam sterilizer is a. the gasket. b. the thermostatic trap. c. the jacket d. the chamber

the thermostatic trap.

Wrapped trays should not be stacked because a. it can cause holes in the wrapper of the bottom tray. b. the trays will be damaged. c. it will cause the shelving to bend

the trays will be damaged

Both the association of periOperative Registered Burses and The Joint Commission recommend that a. the use of IUSS be minimized or decreased. b. IUSS be performed in only one sterilizer per facility. c. Healthcare facilities get the U.S. FDA approval for IUSS.

the use of IUSS be minimized or decreased.

When transporting items that have been IUSSed, it is required that a. the be transported in a closed container. b. they be transported to the patient area within 5 minutes of the completion of the sterilization cycle. c. they be transported in such a manner that reduces the potential for contamination.

they be transported in such a manner that reduces the potential for contamination.

When transporting items that have been immediate use steam sterilized, it is required that a. they be transported in a closed container. b. they be transported to the patient area within five minutes of completion of the sterilization cycle. c. they be allow to property cooled before transport. d. they be transported in such a manner that reduces the potential for contamination.

they be transported in such a manner that reduces the potential for contamination.

Central service technicians need to understand the anatomy of a steam sterilizer a. to know how to properly clean the chamber. b. to understand how the sterilizer operates. c. to understand how to test the thermostatic trap.

to understand how the sterilizer operates.

After sterilization the load contents may take 2 hours or more to cool. a. true b. false

true

All items should be removed from the storage shelves prior to cleaning the shelf. a. true b. false

true

All items sterilized or high level disinfected at point of use must be carefully monitored and logged. a. true b. false

true

All items sterilized or high-level disinfected at the point of use must carefully monitored and logged. a. true b. false

true

Cellulose-containing packaging materials are not compatible with hydrogen peroxide sterilization. a. true b. false

true

Ethylene oxide is toxic gas. a. true b. false

true

Ethylene oxide, hydrogen peroxide and ozone sterilization process must all be monitored using chemical, physical and biological monitors. a. true b. false

true

Information about a device's compatibility with a specific sterilization process should be obtained from the devices's manufacturer. a. true b. false

true

Information about a device's compatibility with specific sterilization process should be obtained form the device's manufacturer. a. true b. false

true

Items that are wrapped moist can be a cause of wet packs. a. true b. false

true

Jewelry is discouraged in sterile storage because it can damage or contaminate packages. a. true b. false

true

One of the goals of stock arrangement is to provide minimal product handling while allowing first in, first out rotation. a. true b. false

true

Sterile packages should be stored no lower than eight to 10 inches from the floor. a. true b. false

true

The guidelines for sterile storages are the same for both items sterilized in house and for items purchased sterile. a. true b. false

true

The steam sterilization process can be affected by the design of the medical device being sterilized. a. true b. false

true

The steam sterilization process can be affected by the design of the medical device being sterilized. a. true b. false

true

The steam sterilization process can be affected by the types of soil present on the devices to be sterilized. a. true b. false

true

To sterilize items using IUSS, the item's manufacturer instructions must state the item can be sterilized using an IUSS cycle. a. true b. false

true

Using the wrong container filter or poor filter placement can be a cause of a wet pack. a. true b. false

true

the sterile storage process starts a. when items are received in the decontamination area. b. after items are sterilized and cooled. c. when the sterilizer door is open.

when the sterilizer door is open.

Factors that can cause sterilant contact failure with the instrument are A. Cleaning, loosely packed load B. Conditioning, size and weight of the instrument C. Solid bottom containers, exposure time D. Crowded loads, clogged drain strainer

Crowded loads, clogged drain strainer

An extended aeration cycle is required for items sterilized in ozone sterilization processes. A. True B. False

False

Temperatures in the sterile storage area should be 64 to 78 degrees Fahrenheit. a. true b. false

False

The process by which instruments are sterilized for immediate use is called? a. emergency sterilization. b. immediate use steam sterilization. c. core sterilization. d. rapid processing.

Immediate Use Steam Sterilization

Which of the following statements about IUSS is true? a. It is the sterilization method of choice for metal instruments. b. It reduces turnaround time because it is not required. c. It should be used only when there is not time to process items using the wrapped method.

It should be used only when there is not time to process items using the wrapped method.

The relative humidity of central service storage area should be A. Less than 70% B. Less than 60% C. Less than 50%

Less than 70%

When loading steam sterilizer, basins should be a. placed in an upright position b. loaded first c. placed on edge d. placed in a wired basket

Placed on edge

Sterile trays should a. not be touched until they are properly cooled. b. lifted not dragged off the sterilizer cart. c. checked to be sure the external chemical indicators have turned the appropriate color. d. all the above

all the above

When loading a steam sterilizer a. basin sets should be placed on edge and tilted. b. solid containers should be placed so air can get out. c. there should be visible space between packs. d. all the above

all the above

IUSS documentation should include a. name of the patient for which the items were sterilized. b. sterilizer number and cycle. c. name of the instrument sterilized. d. all the above.

all the above.

When placing sterile items on the shelf, check a. package integrity. b. an expiration date. c. seals and filters to be sure they are intact. d. all the above.

all the above.

The drain screen in a steam sterilizer must be cleaned a. weekly, preferably daily. b. each cycle c. at least daily

at least daily

Trays that overhang the shelving a. can become contaminated b. is ok for rigid containers but not for flat wrapped trays. c. is an appropriate way to store trays as it allows for the use of proper body mechanics when lifting heavy trays.

can become contaminated

The weakest part of a steam sterilizer is the a. jacket b. gasket c. door d. thermostatic valve

door