Chapter 41 Study Guide
When a direct spark ignition systems electrode and flame rod are packaged together, they provide what is known as ______ sensing
Remote
In gas-fired radiant heaters, about ________% of the heat energy is converted into radiant heat
50
Increasing a furnace's gas pressure can produce the following effects, except ________
A decrease of the flame temperature
In some gas furnaces, a device consisting of an inverted opening in the flue that can operate to help prevent back pressure is known as the ___________
Air break
After an annual gas furnace inspection, the customer should be reminded to shut off the system and notify the technician if there are ______
All the above
Many combustion analyzers can be used to measure
All the above
The stack temperature in a noncondensing gas furnace should be _________
Between 325°f and 500°f
Proper combustion in a gas furnace is shown in a flame that burns the color _______
Blue
The sheet metal chamber where heat collects before being distributed is called the ______
Bonnet
Radiant gas heaters typically use elements made of _______
Ceramic
Flame rectification involves using the pilot flame to _______
Change a small electric current from ac to dc
The type of venting that is composed of masonry is ________
Class A
Type of venting that is composed of double-wall Metal is ________
Class B
The primary action performed by a rollout switch when it is actuated is to
Close the gas valve
A single unit that contains multiple components, such as a manual shutoff, adjustments, and a pressure regulator, is called a _______ gas valve
Combination
A gas furnace produces heat for distribution through _______
Combustion
On modern gas furnaces, the first device that begins operation on a call for heat is the _____
Combustion blower
The higher the efficiency of a gas furnace, the more likely it is to develop ________
Condensation
A hot-surface ignite reaches flame ignition temperature through ___________
Conduction of electrical current
A gas piping installation to a furnace or boiler should include a _______ to trap and collect possible contaminants that may flow with the gas
Drip leg
A gas furnace's ignition control module monitors several _____, which prevent the furnace from operating unless certain conditions are met
Electric interlocks
During normal operation, disadvantage that only a direct-spark ignition system can produce is _________
Electromagnetic interference
The term ultimate carbon dioxide content refers to the specific amount of carbon dioxide by volume that is present in flue gas when the _______ to achieve complete combustion
Exact amount of air is supplied
Thermostatic draft regulators open when a bimetal element senses and reacts to the heat of _______
Flue gas
Category IV furnaces have a ______
Flue gas temperature less than 140°f
Which gas furnace device is very fragile, sensitive to vibration, and easily broken
Hot-surface igniter (glow coil)
The purpose of a standing pilot light is to _____
Ignite the gas burner flame
A single-port burner that directs the mixture of air and fuel gas through a large orifice to produce a large flame is a _______ burner
Inshot
Which two functions does a combustion blower perform
It pre-purges the heat exchanger and exhausted the flue gases
If a gas furnace has a fuel-air mixture with natural gas below 4%, the mixture is considered _________ for combustion
Lean
A _______ flame indicates that gas velocity is faster than the speed the gas can burn
Lifting
A gas furnace that does not burn natural gas is most likely adjusted to burn _________
Liquified petroleum (LP) gas
A gas valve provides low-pressure gas to the _______
Manifold
Combustion blowers are used in _______
Mid-efficiency and high-efficiency furnaces
As the amount of excess air increases, ______
More heat is carried through the flue to the outdoors
On a gas furnace service call when measuring flame sensor rectification, use a _________
Multimeter
In low-efficiency gas furnaces, flue gases are moved outdoors by _________
Natural convection
An ignition control module has _______ if it closes the gas valve but not the pilot valve when the flame rod does not detect a flame
Non-100% shutoff
An intermittent-pilot ignition system burns and monitors its pilot light _________
Only while the thermostat is calling for heat
The important element that must be present in proper amounts and is consumed as it supports combustion is __________
Oxygen
Factors that affect pipe size in a gas piping installations include the following except _____
Piping material
A primary difference between non interfered ignition controls and integrated ignition control is the ability to ________
Preform self-diagnostic function
In a gas furnace application, a switch that connects to the end of a damper motor shaft is a ______ switch
Pressure
The primary variables that determine a furnace's venting classification are the _____ of the flue gas
Pressure and temperature
The gas supply to a gas furnace is maintained at a low pressure by the __________
Pressure regulator
If the gas burners are operating when the combustion blower is not operating, the ______ may be ruined
Pressure switch
A burner that produces a solid flame along the top of its long, horizontal orifice is a _______ burner
Ribbon
If a gas furnace has a fuel air mixture with natural gas over 14%, the mixture is considered ______ for combustion
Rich
A flow switch that uses a large paddle to catch a draft to open or close its contacts is a ______ switch
Sail
Air that is added to a flame after ignition is _______
Secondary air
A burner that produces a series of individual flames along a row of horizontal orifices is a ________ burner
Slotted
Flame rollout is when a furnace's flame ______
Spills backward out of the burner
Gas radiant heating is primarily used for ______
Spot heating
Specially sized orifices attached to the gas manifold are ______
Spuds
Category III furnaces require venting made of _______
Stainless steel
Another term for present combustion is ______ combustion
Stoichiometric
During normal system operation, a gas valve allows flow primarily when __________
The thermostat calls for heat
The safety device used in a standing pilot system to sense the pilot is a _________
Thermocouple
The stack temperature in a condensing gas furnace should be ________
Under 140°f
Flame rectification is used for the primary purpose of _______
Verifying the presence of a pilot flame
Furnace gas pressure is usually measured in ______
in. WC
A chimney or pipe should extend at least ______ above the highest part of a roof
2'
Air mixed with the fuel prior to ignition is _______
Primary air