The NEC permits all bathroom receptacles to be on a single ____ branch circuit so long as it doesnt supply other loads
20 amp
ceiling-suspended paddle fans must be located within a zone measured ____ horizontally and ___ vertically from the top of a shower stall treshold
3ft , 8 ft
some inspectors consider the area within a ______-degree angle from a roof line or overhang to be a damp location
45
A doorjamb switch is usually mounted about _____ feet above the floor, on the inside of the 2x4 framing on the hinge side of the closet door.
6
a bathroom is defined as " an area including a basin,with one or more of he following
Toilet,Bidet,Tub
some portable appliances use double insulation place of grounding to provide shock protectionto users. Double insulated appliances normally have ___ power cords and attachment plug caps
Two wire
GFCI protected receptacles ____ permitted to be installed within a tub or shower space.
are nott
as defined in article 100, a bathroom is required to have a _____
basin
code classifications for open front porch
damp location
code classifications for receptacle on the bottom side of a roof overhang
damp location
with_____ products,it takes two failures to create a shock hazard to the user
double-insulated
lighting fixtures intended for installation in wet locations must be ____.
marked"suitable for wet locations"
Recessed or surfaced-mounted luminaires and recessed exhaust fans may be located within the restricted zone near the bathtub
may
The Code permits GFCI protected receptacles to be installed _____ inches from a tub or shower space
none of the above
A location exposed to the weather is a _____ location
wet
install luminaries listed for _____ locations if they will subject to shower spray
wet
code classifications for house side wall
wet location
code classifications for pole mounted light in a yard
wet location
When using nonmetallic boxes, the volume allowance is based on ______
wiring devices,cablle clamps, equipment grounding conductors