A short section of roadway that lies perpendicular to the end of a dead-end street with equal sections on each side of the dead end is a ____ turnaround. pg 288

"T"

Water has a specific gravity of: pg 90

1

Illuminated exit signs must be positioned so that no point in the exit access is more than: pg 263

100 feet (30 m) from the nearest visible sign.

What size outlets should generally be used to conduct hydrant flow tests? pg 484

2½-inch (65 mm)

A permanent record of all detector tests must be maintained for at least: pg 640

5 years

The actual hose connections of a standpipe hose valve can be located no more than: pg 530

6 feet (1.8 m) from floor level.

What percentage of finished foam is water? pg(580)

94% to 99½%

Incineration can reduce the bulk of waste as much as: pg 333

95 percent.

What is a "mixed occupancy"? pg 131

A situation in which a variety of occupancies may be included in the same structure

Which is the BEST option for preventing an owner/occupant from attempting to omit a requirement? pg 652

A team approach

Which type of locking hardware requires that the occupant use a security card or enter a code to gain entrance? pg 254

Access-controlled egress

Which of the following establishes the basis for all future inspections of a building? pg 654

Accurate and complete record keeping during plans review and field verification visits

Which dry-chemical system component releases agent into the piping system? pg(568)

Actuating mechanism

What can an inspector advise property owners to do to increase safety in temporary occupancies? pg 141

Add additional signage and fire protection

In what way does the combustibility of an interior finish contribute to fire behavior? pg 217

Adds to the intensity of the fire because it contributes fuel

What information do calculations or graphical analyses from fire flow tests provide? pg 479

Amount of water flow from individual hydrants

What type of shingle produces characteristically black smoke? pg 200

Asphalt shingles

Which of the following must inspectors understand to perform their jobs properly? pg 14

Assigned duties

How often should control valves be exercised? pg 474

At least once a year

Which listening skill focuses on the speaker and ignores other distractions? pg 692

Attending

Who generally establishes requirements for marking fire lanes and access roads? pg 289

Authority Having Jurisdiction (AHJ)

Which of the following establishes the minimum level of training for inspectors and code officials and defines the certification requirement? pg 17

Authority having jurisdiction

Which foam proportioner is one of the most reliable methods of foam proportioning? pg(583)

Balanced pressure proportioner

Why are breaches in party walls against code regulations? pg 195

Breaches make it possible for fires to communicate from building to building.

Which type of masonry is produced from a variety of locally available clay and shale? pg 161

Brick

Which of the following barriers could pose access problems for aerial apparatus? pg 297

Building canopies

Who is responsible for tracking changes to an electrical system? pg 322

Building custodian

Which of the following activities is considered open burning under most model fire codes? pg 310

Burning combustible waste in metal drums

Which type of control valve usually has a rubber or rubber- composition seat that is bonded to the valve body? pg 474

Butterfly valve

Which fire extinguisher agent extinguishes primarily through a smothering action? pg(587)

Carbon dioxide (CO2)

What should an inspector be prepared to issue regarding an inspection site for extremely hazardous conditions? pg 704

Cease-and-desist order

Which supervising station is recognized as the most reliable? pg 618

Central

What resource can fire inspectors use to identify incompatible hazardous materials storage? pg 399

Chemical Compatibility Matrix

Which class of fire involves energized electrical equipment? pg(565)

Class C

Which classification of standpipe and hose fire suppression systems is primarily designed for use by building occupants trained in its use or by fire department personnel? pg 526

Class II

Which type of roof covering has excellent resistance to flying embers? pg 200

Clay and slate tiles

Which of the following actions is an example of how an inspector can control external interference during an inspection? pg 691

Close a door or window

Which department is MOST likely responsible for vacant structures? pg 16

Code enforcement department

Which automatic sprinkler system is used in special circumstances where an additional level of protection against false activation is required, such as in data centers or museums? pg 507

Combined dry pipe and preaction sprinkler system

The National Building Code of Canada (NBC) defines three types of building construction: pg 125

Combustible, noncombustible, and heavy-timber.

What kind of permit does the removal of medical gas systems require? pg 55

Construction

Which of the following makes inspector site visits more efficient and effective? pg 653

Coordinating inspections with completion dates

Which type of identification features a descriptive name, identification number, weight, or specification that includes instructions, cautions, or UN marks required on outer packaging containing hazardous materials or goods? pg(409)

DOT markings

Which of the following would MOST likely be an acceptable bolt lock? pg 254

Deadbolt locks that operate with the action of the latch and do not require keys, special tools, or knowledge to operate

What determines the occupancy classification of a one- or two-family dwelling? pg 139

Degree of fire separation of units

Which type of sprinkler systems operate when an electronic detector or manual control device is activated? pg 504

Deluge or preaction sprinkler systems

Who evaluates used storage equipment before it can be used again safely? pg 381

Design professional

Which of the following MOST likely occurs during a routine inspection? pg 18

Determine occupancy classification

Which of the following drivers is MOST likely to be used where a driver independent of the local electrical power supply is needed? pg 536

Diesel engine

Which controller monitors and contains alarms for conditions such as low engine oil pressure and high engine coolant temperature? pg 537

Diesel engine controller

What should an inspector do when an owner/occupant denies access to the property to be inspected? pg 704

Document the action and follow departmental protocols for securing permission to obtain legal access.

What should an inspector do when encountering an external barrier during an inspection? pg 294

Document the existence and condition

Which valve is used to drain water from piping when pressure is relieved in the pipe? pg 510

Drain valves

Which of the following is the MOST accurate regarding code provisions that must be implemented for open-yard storage? pg 330

Driveways must be wide enough to accommodate the largest apparatus.

Which of the following statements about exterior insulation and finish systems (EIFS) is MOST accurate? pg 170

EIFS are flammable and can be ignited from radiant heat

Why is it important for inspectors to keep specific, official records about apartment buildings? pg 143

Each apartment building presents a unique set of problems

Which of the following is the most common method for driving a fire pump? pg 535

Electric motor

Who is usually responsible for detailed electrical inspections? pg 320

Electrical inspectors

Which record-keeping method makes cross-referencing complaints easier? pg 51

Electronic record keeping

Which guidebook is primarily a guide to aid emergency responders in quickly identifying the hazards of materials involved in an emergency incident? pg 418

Emergency Response Guidebook (ERG)

Which of the following creates the inspection position or designates individuals to perform fire and life safety inspections? pg 14

Enabling legislation

Which fire pump includes advantages such as ease of installation, simplified piping arrangement, and reduced pipe strain? pg 534

End suction

When topographical conditions impede access to a building, what can be done? pg 298

Establish alternative access points

Which of the following is the responsibility of the prosecutor during a preliminary hearing? pg(22)

Establish that a crime was committed by the arrestee

Which of the following is a protected path consisting of exit components constructed of approved fire-resistance-rated assemblies? pg 246

Exit

Why do educational occupancies present significant challenges for inspectors? pg 133

Facilities are used for a wide variety of activities

Who is responsible for the inspection, testing, and maintenance of private water supply systems? pg 466

Facility owners/occupants

Which of the following witnesses answers questions posed by an attorney regarding what he or she saw, heard, touched, smelled, or tasted? pg 24

Fact witness

Which of the following is an example of an internal access barrier? pg 302

False fronts

Which element of the communication model completes the communication process? pg 691

Feedback

Who is responsible for explaining the site's emergency response procedures and has access to the facility's safety data sheets? pg 380

Fire department liaison

What can building and fire inspectors use to identify fire door classification when in the field? pg 210

Fire door labels

Which of the following statements about access for construction and demolition sites is MOST accurate? pg 293

Fire lane and fire apparatus access road requirements apply

What are some of the elements an inspector should look out for in a structure that has been converted from a warehouse to apartments? pg 131

Fire protection systems, exit signage, emergency lighting

Which type of walls act as barriers to fire spread? pg 194

Fire-rated partition walls

Which are applied to the surface of combustible materials to suppress, reduce, or delay the flame-spread rating of a material? pg 154

Fire-retardant coatings

On which principle of physics does a rate-of-rise heat detector operate? pg 627

Fires rapidly increase the temperature of a given area

Where are military markings typically used? pg 414

Fixed facilities

Which type of sprinkler is mounted in a ceiling with the body of the sprinkler, including the threaded shank, above the plane of the ceiling? pg 512

Flush

Which fire suppression system is commonly used to protect Class B fire hazards and can be a wet-pipe, dry-pipe, preaction, or deluge system? pg 523

Foam-water system

Which type of gypsum board is used to replace the vapor barrier in outside walls? pg 168

Foil-backed gypsum board

Which of the following is known as the reducing agent in a combustion reaction? pg 87

Fuel

During what stage are flammable products of combustion likely to flow from the compartment of origin into adjacent compartments? pg 108

Fully developed

Which type of glass breaks into small granules rather than large, sharp-edged chunks and is used in windows that might be subject to high wind forces? pg 166

Fully tempered

Which of the following statements about vapor density is MOST accurate? pg 89

Gases with a vapor density less than 1 will rise.

Which of the following is an example of improper use and storage of flammable and combustible liquids? pg 313

Gasoline stored in glass jars in a garage

Who should the inspector notify when violations are found during a site visit? pg 654

General contractor

During which stage does fire begin to influence the environment within the compartment? pg 104

Growth

Which type of materials are those where a single brief exposure to the hazardous material can result in death, injury, or incapacitation? pg 396

Health hazards

Which of the following refers to the total amount of thermal energy released when a specific fuel amount is oxidized?

Heat of combustion

Which of the following refers to energy released per unit of time as a fuel burns? pg 88

Heat release rate

Which foam expansion rate is useful as a space-filling agent? pg(582)

High

Which fire door classification method is still approved for use? pg 209

Hourly fire protection rating

When a fire is not controlled in a sprinkler-equipped building, which of the following is MOST likely a cause? pg 504

Inadequate or lack of water supply

Which of the following statements about incinerators is MOST accurate? pg 333

Incinerators are effective in destroying medical, chemical, and biological wastes.

Which component sends a signal to the FACU using either hard-wire systems or a signal conveyed by radio wave over a special frequency? pg 610

Initiating device

Which of the following tasks regarding dry-chemical systems is an Inspector I MOST likely to be required to perform? pg(566)

Inspect new installations

Who is responsible for verifying that buildings are accessible and that entry is not impeded? pg 294

Inspectors

Which of the following is MOST appropriate regarding NFPA® 1031 and training? pg 17

Inspectors are not required to meet Fire Fighter I, Fire Fighter II, or Fire Officer certification

Which of the following is MOST likely to reduce water supply requirements for a standpipe fire suppression system? pg 529

Installed automatic sprinklers

Which of the following thermal properties of a compartment contains heat within the compartment, causing a localized increase in the temperature and fire growth? pg 102

Insulation

Which of the following is a model code organization in the United States? pg 43

International Code Council® (ICC®)

Which type of smoke detector contains a sensing chamber consisting of two electrically charged plates and a radioactive source? pg 631

Ionization smoke detectors

What should an inspector do if none of the violations have been corrected and no effort has been made by the owner/occupant to correct the violations? pg 715

Issue a final notice with a date for another inspection

If an access issue goes unaddressed at a construction or demolition site, what can an inspector do for enforcement? pg 294

Issue formal citations against the general contractor

Which of the following is the primary reason that concrete is reinforced through the use of steel bars or cables placed within the concrete? pg 163

It cannot be used alone where significant tensile forces occur in a structure.

Which acute toxicity value refers to the concentration in the air of a given substance that killed 50 percent or more of the test population? pg 397

LC50

Which glass is MOST likely to be used in security windows and to reduce noise transmission? pg 166

Laminated

What must be provided when flights of stairs are greater than 12 feet (3.5 m) high? pg 258

Landings

What serve as official records of an inspection and form the basis for legal action when required? pg 714

Letters and reports

Which gases become liquids at ordinary temperatures and pressures? pg 388

Liquefied compressed gases

Which of the following MOST impacts the rate at which unprotected steel fails when exposed to fire? pg 164

Load supported by the steel

What entity is usually responsible for public water supply systems? pg 466

Local government

Which corner must display the hazard class or division number on placards corresponding to the primary hazard class of a material? pg 404

Lower

Which type of dry powder agent is sodium chloride (salt) based? pg(571)

MET-L-X®

Which of the following is a recommendation for exposure protection? pg 328

Maintain required separation between materials

What should inspectors refer to when trying to determine the coefficient of discharge for a specific nozzle? pg 482

Manufacturer's recommendations

How does the presence of an automatic sprinkler system typically impact the fire-resistance rating required for a fire wall? pg 194

May reduce or eliminate the need for fire walls

What basic element of a communication model gives the path that a message takes? pg 690

Medium

Which of the following criminal violations generally results in a fine or term of less than two years? pg 21

Misdemeanor

Which type of foam fire extinguishing system is wheel mounted and may have a water supply connection capability? pg(579)

Mobile

What defines the types of situations that require a permit or license? pg 52

Model codes

How often should the auxiliary power supply and emergency lighting system be tested? pg 265

Monthly and annually

Which automatic sprinkler system is designed to be operated repeatedly in response to a detection device and shuts on and off based on the demand indicated by the detection device? pg 507

Multicycle sprinkler system

Which consensus standards committee develops and publishes the majority of the standards concerning fire protection, electrical systems, and life-safety systems used in the U.S. and Canada? pg 48

National Fire Protection Association® (NFPA®)

What agency has attempted to study the relationship between types of finishes and fire behavior? pg 217

National Institute for Standards and Technology (NIST)

Which task in Monroe's Motivated Sequence Pattern involves describing the problem and demonstrating a need for a change? pg 695

Need

Which of the following categories of inspection includes demolition of a structure? pg 18

New construction

Which of the following categories of inspection occurs when an existing structure is altered in such a way that code compliance must be determined? pg 18

New construction

Which of the following would MOST likely result in a civil proceeding? pg 20

Noncriminal violation

Which of the following MOST accurately describes the staffing for fire prevention divisions in a fire department? pg 15

Nonsworn or sworn personnel inspectors

Which of the following is the formula for determining the occupant load of a structure, room, or area? pg 266

Occupant Load = Net Floor Area ÷ Area per Person

Which of the following statements about siding is MOST accurate? pg 159

Older buildings may have multiple layers of siding

When are model codes enforceable? pg 43

Once adopted by the authority having jurisdiction (AHJ)

What kind of permit does open burning require? pg 55

Operational

Which of the following refers to unintended resistance heating? pg 81

Overcurrent or overload

Who is responsible for training employees in emergency evacuation of hotels and motels? pg 722

Owner or administrator

Which of the following categories of inspection is MOST likely to be conducted because it is required by another government agency or an insurance company? pg 18

Owner/occupant request

How do responding firefighters know where fire lanes and fire apparatus access roads are located? pg 289

Painted curbs and posted signs

Which type of building and fire code or standard classification is more flexible? pg 44

Performance-based code/standard

Which type of driveway design is more effective than simply following a minimum code requirement? pg 294

Performance-based design

Which of the following grants a property owner or other party permission to perform a specific activity? pg 52

Permit

When it comes to open burning, what do most model fire codes require for individuals? pg 310

Permits

What type of materials should always be kept separate from oxidizers because their interaction will be immediate and violent? pg 392

Petroleum-based materials

Which type of smoke detector works on all types of fires and usually responds more quickly to smoldering fires than ionization smoke detection? pg 630

Photoelectric smoke detectors

Which type of ignition occurs when a mixture of fuel and oxygen encounter an external heat source with sufficient heat or thermal energy to start the combustion process? pg 79

Piloted ignition

Which commodity must be considered high-piled combustible storage if stored above a specific height above the finished floor? pg 325

Plastic

Which type of rate-of-rise heat detector can monitor large areas of a building? pg 627

Pneumatic rate-of-rise line heat detector

Which of the following statements about public emergency alarm reporting systems is MOST accurate? pg 621

Power interruption may result in the alarm only sounding locally.

The term "model code" describes which type of building and fire code or standard classification? pg 43

Prescriptive-based code/standard

Which foam proportioner allows for automatic proportioning over a wide range of flows and pressures and does not depend on an external power source? pg(584)

Pressure proportioning tank system

Which of the following inspectors function as risk assessors? pg 16

Private fire safety inspectors

Which supervising station is used to protect large commercial and industrial buildings, high-rise structures, and groups of commonly-owned facilities? pg 619

Proprietary

Which alarm system is designed to provide notification to building occupants only on the immediate premises? pg 614

Protected premises (local)

Of the primary storage methods, which common storage method represents the most challenging fire protection problem? pg 324

Rack storage

Which type of heat transfer involves the transmission of energy as electromagnetic waves without an intervening medium?

Radiation

Which of the following would MOST likely be an appropriate area of refuge? pg 245

Rated stairwell

What should an inspector do when conditions that may trigger an unwanted alarm or environmental conditions that may negatively affect a system are recognized? pg 637

Recommend corrective action

What is the easiest way to determine how much water is flowing from a hydrant outlet? pg 482

Refer to prepared tables for nozzle/outlet discharge

Which description below is the generally accepted color design for information signs? pg 289

Reflective white background with red lettering

What is the biggest disadvantage to dry-chemical systems? pg(567)

Require extensive cleanup

Which of the following is a common access problem for construction and demolition sites? pg 293

Roadway not maintained in serviceable condition

Which resource is a detailed information bulletin prepared by the manufacturer or importer of a chemical to describe or give information about hazards? pg 402

Safety data sheets

Which component can consist of batteries with chargers, engine-driven generators with a storage battery, or multiple engine-driven generators? pg 611

Secondary power supply

Which of the following is an important life safety function of doors? pg 251

Separate occupants from the movement of fire, smoke, and other toxic gases

What is one of the factors that determines whether an inspector needs to give advance notice or to obtain an administrative warrant to enter the location? pg(51)

Severity of the complaint

Which component is MOST likely to affect fire behavior by ignition due to an exposure fire? pg 159

Siding

What must be verified to ensure that fire and life safety requirements are met during construction? pg 654

Site access

When inspecting or designating dead-end turnarounds or access roads, what factors into the road dimensions? pg 289

Size and turning radius of fire apparatus

Which is an advantage to manufacturing laminated members? pg 155

Sizes and shapes can be produced that are not available from solid wood

Which dry-chemical agent is also known as ordinary dry chemical? pg(567)

Sodium bicarbonate

Which type of insulation is gaining popularity and is applied as soft foam that hardens after application? pg 159

Solid-fill foam insulations

Which detection and activation device occurs when thermocouples reach a preset temperature, releasing the sprinkler plug? pg 516

Sprinkler activation

Which Canadian entity represents Canada's interests in standards-related matters in foreign and international forums? pg 50

Standards Council of Canada (SCC)

Which tanks are located at ground level and provide a water supply source for fire pumps? pg 469

Suction tanks

Which type of fire detection and alarm system specialty signal indicates an off-normal condition of the complete fire protection system? pg 613

Supervisory signal

Which type of hydrant should be located as close as possible to the location requiring flow test results? pg 485

Test hydrant

If metal bars or grilles are encountered during an inspection, what should the inspector do? pg 216

Test the operation

Which consensus standards committee administers and coordinates the voluntary standardization and conformity assessment system? pg 49

The American National Standards Institute (ANSI)

Why is it important for fire inspectors to maintain access and inspections of construction and demolition sites? pg 292

The conditions at these sites change frequently.

What presents a specific concern about the flame resistance of wood floors? pg 200

The floor's finish

Why are Type IV structures more resistant to collapse than other construction types? pg 122

The structural elements form an insulating effect that reduce heat penetration to the inside of the beam.

Which of the following statements about a physical change is MOST accurate? pg 74

The substance remains chemically the same but changes in size, shape, or appearance.

Which of the following is the BEST definition for occupant load? pg 265

The total number of persons for which the means of egress of a building or portion thereof is designed

Which of the following is a challenge for inspectors regarding intumescent coatings? pg 157

These coatings are often painted over or not maintained.

What makes wood trusses appealing in Type V structures? pg 124

They can support large loads over relatively large spans.

Which of the following statements about exit stairways is MOST accurate? pg 258

They cannot be used for any purposes other than as a means of egress.

Which of the following statements about fires originating in upper levels of a building is MOST accurate? pg 101

They generally extend downward much more slowly.

Which of the following is a primary concern of mortar joints in masonry units? pg 161

They may deteriorate over time or when exposed to fire and result in weakening of the structure.

Which of the following statements about fire escape stairs and new construction is MOST accurate? pg 260

They may not be used as any part of a means of egress.

Which of the following statements about liquids with a specific gravity of less than 1 is MOST accurate? pg 90

They will float on the surface of water

What is the purpose of an enclosure wall? pg 196

To prevent the vertical spread of fire through a building

Why were occupancy loads established? pg 125

To provide building officials with a reasonable expectation of the hazard level of a structure

Which type of dry-chemical fixed application method introduces a concentration of agent into a closed area? pg(566)

Total flooding

Which type of specialty signal indicates loss of primary power or failure or removal of an initiating device? pg 613

Trouble signal

Which type of emergency communications system is MOST helpful to fire suppression personnel operating in a building? pg 622

Two-way communication systems

Which type of gypsum board contains vermiculite that expands as it is exposed to heat and allows the gypsum to maintain its integrity? pg (167)

Type C gypsum board

Which construction type is the strictest in terms of the amount of combustible materials allowed? pg 120

Type I

Which type of gypsum board is produced with glass fibers that help prevent its deterioration when exposed to fire? pg 167

Type X gypsum board

Why is the type of floor covering a frequent source of concern for inspectors? pg 257

Unapproved materials are often used during remodeling

Which consensus standards committee provides third-party testing and certification and labels products that have been tested? pg 49

Underwriters Laboratories (UL)

Which element was added to the basic fire model to create the fire tetrahedron?

Uninhibited chemical reaction

An open flame is an example of which of the following unsafe behaviors? pg 308

Unintentional ignition sources

Which type of sprinkler is installed upward from a line so that water is discharged up against the deflector? pg 512

Upright

Which of the following statements about revolving doors is MOST accurate? pg 206

Using revolving doors as a means of egress is restricted.

Which fire pump includes advantages such as the ease of installation as a replacement pump, the compact space required for the pump, and the ease of maintenance of the pump and driver? pg 534

Vertical inline

Which stationary fire pump is almost always driven by an electric motor that sits on top of the pump? pg 533

Vertical split-case

For which fire pump are the impellers actually located within the water supply source? pg 534

Vertical turbine

What is the most difficult aspect of dealing with people while conducting an inspection? pg 713

Violation discussions

Which of the following is a characteristic of flaming combustion? pg 76

Visible flames above the material's surface

Which task in Monroe's Motivated Sequence Pattern includes describing the solution for the problem and how it will benefit the listener? pg 695

Visualization

Which of the following is an inspector's chief interest in masonry used in construction? pg 160

Wall construction

Which type of facility presents a unique challenge due to the quantity of materials, the presence of treated and untreated materials, and the processes used on those materials? pg 332

Waste-handling facilities

In certain occupancies, when may open stairs be used as a part of the means of egress? pg 258

When the building has an automatic sprinkler system

Which resource available to assist inspectors in determining classifications is a free internet-based search engine and a compilation of a number of databases developed by several U.S. agencies? pg 386

Wireless Information System for Emergency Responders

Which of the following is a common cause of electrical hazard fires? pg 320

Worn electrical equipment

Horizontal exits require fire walls or fire-barrier walls with at least: pg 248

a 2-hour fire-resistance rating.

When occupants remain in a building during construction, and a fire detection or alarm system will be nonfunctional for any length of time: pg 654

a fire watch should be posted.

The four elements necessary to produce high-quality fire fighting foam include foam concentrate, water, mechanical agitation, and: pg(580)

air.

Ideally, inspection records should be maintained for ____ properties or facilities within a jurisdiction. pg 697

all

Inspectors should check the FACU to verify: pg 638

all parts are operating properly.

Under fire conditions, a fire wall must have sufficient structural stability to: pg 194

allow the collapse of construction on either side without the wall itself collapsing.

Converting water from a liquid to a gas requires: pg 75

an endothermic reaction

If the owner or contractor fail to follow the requirements of the building or fire code, records may be required for use in: pg 654

any legal action.

Interior building elements in Type IV construction: pg 122

are solid or laminated wood with no concealed spaces.

Remote station and proprietary systems should be tested according to requirements established by: pg 641

authority having jurisdiction (AHJ).

When a more challenging commodity is introduced or the height of storage is increased, the ____ must be evaluated to confirm the protection is adequate. pg 326

automatic sprinkler system

In open areas like atriums, building codes require: pg 202

automatic sprinklers.

Fire lanes and fire apparatus access roads should be designed to: pg 296

bear the weight of the jurisdiction's heaviest fire apparatus.

Two main hazards associated with recycling plants include: pg 331

bulk storage and hazardous processes.

Dry cleaning and laundry facilities are considered _____ occupancies. pg 133

business

The special-agent fire extinguishing system that is extremely cold and can freeze exposed skin is the: pg(574)

carbon dioxide (CO2) system.

The general category of fire extinguishing agents that effectively leaves no residue is a: pg(572)

clean agent system.

A code war is destructive to the _____ process as well as to the professional image of all involved departments. pg 47

code enforcement

According to NFPA® National Electric Code, Class II locations contain: pg 313

combustible dust.

Storage tanks located throughout a water distribution system are usually constructed of: pg 474

concrete or steel.

Inspectors following the same sequence for similar types of occupancies increases the: pg 705

consistency of the inspection process.

The building and fire codes specify the requirements for the _____ of stairs. pg 204

construction and use

Nonbulk packages containing liquefied compressed gases, cryogenic fluids, or liquids with a high vapor pressure must: pg 435

contain a means of venting.

Any additions or alterations to existing structures will be regulated by the ____ code. pg 45

current

Automatic alarm-initiating devices are more commonly known as: pg 623

detectors.

The system for moving water by installing pumps in the distribution system when elevation pressure cannot provide sufficient pressure is a: pg 470

direct pumping system.

Conducting plans review enables plans examiners to: pg 653

discover any errors or omissions in a building plan.

Issuing a permit to a party: pg 52

does not relieve the party of meeting minimum code requirements.

Before beginning a flow test, an inspector should verify that the air chamber on the pitot tube is: pg 481

drained.

When rapid fire extinguishment is required and reignition is unlikely: pg(565)

dry-chemical systems are used

When inspectors exercise enforcement power they must ensure that the legal rights of the accused are protected; this is known as: pg 19

due process

The occupant load for a building or room is established: pg 265

during the plans review process.

Provincial occupational health and safety regulations in Canada typically place the responsibility of safeguarding the health and safety of workers on the: pg 422

employers.

Whenever possible, fire lanes or fire apparatus access roads should ____ a structure. pg 288

encircle

Reactions that give off energy are called: pg 75

exothermic.

When discussing violations, nothing erodes an owner/occupant's confidence in an inspector more than: pg 713

finding a mistake.

The fire alarm component that serves as the brain of an alarm system is called the: pg 608

fire alarm control unit (FACU).

During a fire, an inspector is responsible for accurately identifying and describing conditions within storage facilities and big-box stores to: pg 323

fire suppression units.

According to NFPA® National Electric Code, Class I locations contain: pg 313

flammable vapors and gases.

Large buildings having two or more zones require a fire department connection (FDC): pg 531

for each zone.

If they are to be useful during an emergency, all of the elements of a means of egress must be: pg 246

free from obstructions and combustible materials.

The interlocking network of water mains that compose a water distribution system is referred to as a: pg 472

grid system.

Permits are issued to ensure that _____ are not allowed to develop without approval of the AHJ. pg 52

hazardous situations

According to NFPA® National Electric Code, Class III locations contain: pg 313

ignitable fibers.

Exterior insulation and finish systems (EIFS) provide a way to: pg 170

improve the appearance of an existing masonry wall that has become deteriorated.

An inspector should process and act upon each complaint: pg 722

in a consistent manner.

If the needle on the pressure gauge is fluctuating, read and record the value located: pg 482

in the center between the high and low extremes.

Plastics in an occupancy add to the amount of fuel and: pg 169

increase the toxicity of products of combustion.

An inspector's duties will vary based on the: pg 14

inspection organization's type and size

The insurance company's policies and procedures dictate the working relationship between the: pg 17

insured and the inspector.

Energy possessed by a moving object is known as: pg 78

kinetic energy.

The only way to identify a cylinder's contents is by the: pg 430

labeling or marking on the cylinder.

There are several basic building elements that are found in every structure including a structural frame and: pg 117

load-bearing walls

The AHJ establishes a plans review and permitting process to verify structures that are new, remodeled, or have a change in occupancy classification meet the requirements of: pg 651

locally adopted building and fire codes.

Markers must be in sufficient numbers along a pipeline to identify the pipe's: pg 414

location.

The basic water supply system component that includes water pumps is: pg 466

means of moving water.

Inspectors should evaluate and ____ all landscape situations that can potentially interfere with emergency response. pg 298

mitigate

The majority of local building codes are based on _____ developed by third-party organizations. pg 116

model codes

Modern synthetic building wraps are much: pg 158

more fire resistant than felt or tar paper.

Facilities required to meet multiple codes may be subject to _____ code requirements. pg 45

more restrictive

In institutional/health care facilities, an inspector may find that: pg 136

more than one fire and life safety code applies.

A ceiling that is part of a means of egress: pg 257

must have the same fire-resistance rating as the walls.

Type I structures are composed of only ____ materials. pg 118

noncombustible

Valves in water systems are usually the ____ type and located underground. pg

nonindicating

Usually, all e-mail messages that are written by public officials during the performance of their duties are: pg 696

official documents.

Hydrant discharge outlets are considered standard if they contain: pg 477

one large (4- or 4½-inch [100 mm or 115 mm]) outlet and two hose outlet nozzles for 2½-inch (65 mm) couplings.

Where two or more exits are required, no more than _____ of the exits can be equipped with security grilles. pg 256

one-half

The best way to improve good listening skills is to: pg 693

practice.

Water mains that convey large quantities of water to various points are: pg 472

primary feeders.

An inspector should evaluate factory/industrial structures based upon those requirements that pertain to the structure's: pg 134

primary use

The stage of foam formation that mixes water with foam liquid concentrate is: pg (580)

proportioning.

Fire doors ____ egress pathways. pg 207

protect

All levels of government have created fire inspection and code enforcement organizations to accomplish the goal of: pg 14

protecting lives and property

Utilizing fire lanes and fire apparatus access roads facilitates the approach to structures that are located away from: pg 285

public roadways.

Complaints that do not require immediate attention can be: pg 51

routinely assigned to inspection staff.

Criminal proceedings are MOST often initiated as a result of: pg 20

serving an arrest warrant

To determine whether an administrative warrant to enter a location is needed, an inspector considers the type of occupancy, location within the occupancy, and: pg 724

severity of the nature of the complaint.

On construction drawings, abbreviations and symbols are widely used and plans reviewers: pg 655

should be familiar with some of the more commonly used abbreviations and symbols.

Insulating materials delay heat transfer primarily by: pg 84

slowing conduction

The preferred type of automatic alarm device in residences and health and institutional care facilities is a: pg 630

smoke detector.

Vertical openings that are commonly left unprotected include: pg 202

space around pipes and cables.

Wet-chemical fire extinguishing agents are delivered to the hazard area in the form of a: pg(572)

spray

Water distribution and storage systems include: pg 466

storage tanks, control valves, piping systems, and hydrants.

Generally, exit doors used as a means of egress must be _____ doors. pg 205

swinging

When inspecting areas that involve noisy operations, it may be necessary to: pg 691

take notes.

IFC and NFPA® 400 requirements for the integrity of tanks and piping include verifying that tank vents are operational and that: pg 449

tanks and piping are free of any leaks.

Tanks with integral secondary containment that cannot be visually monitored require an electronic means of leak detection, which requires periodic: pg 449

testing.

In residential board and care occupancies, the evacuation capabilities must be properly classified based on pg 137

the resident posing the most significant risk.

Model code organizations have developed classifications that separate each occupancy into risk categories based upon: pg 125

the use of the structure or space.

A stair's rise and run refers to minimum and maximum rise and: pg 203

tread

When inspecting or designating a fire lane or fire apparatus access road, inspectors must be familiar with: pg 286

turning radius requirements for apparatus

When a hazardous material is moved from its original container, it is considered: pg 430

use.

The special-agent fire extinguishing system most effective on fires in commercial cooking equipment that produces grease-laden vapors is a(an): pg(571)

wet-chemical system.

Emergency lighting is designed to provide illumination: pg 263

when normal power is lost


Related study sets

Chapter 55: Caring for Clients with Disorders of the Male Reproductive System

View Set

Computer Science II - Midterm Practice

View Set

Immune sys---Lupus, arthr/connect IGGY 20, Chapter 18 Iggy Practice Questions, Chapter 46 10th edition, Brunner Chapter 39, Musculoskeletal Trauma

View Set

domain quiz - lifespace development

View Set

Chapter 4: Understanding Food and Nutrition Labels

View Set

Unit 8: Global Atmospheric Change

View Set

الوحدة الأولى: المقدمة والمخالفات المرورية والنقاط المرورية

View Set