HVAC 2 Exam Review
Which of the following factors increases friction loss in a water pipe?
Increased water velocity
How many air temperature sensors does a dry-bulb economizer use?
One
The material commonly used for the under-floor loop in radiant floor heating systems is
PEX tubing with an oxygen barrier
If a heat pump works normally in the heating mode but will not provide cooling or defrost mode, which component is most likely defective?
Reversing valve
Why is a 24VAC common lead connected to a digital thermostat?
To power the thermostat
The variable-speed indoor fan motor receives low-voltage input signals by way of
a 16-pin connector
If the outdoor check valve sticks closed during the cooling cycle, there will be
a low suction pressure and high superheat at the indoor coil
The condensate from a condensing boiler is
acidic
In an electronic air cleaner, the output of the high-voltage power supply is applied to
both the collector and ionizer
An economizer uses mixed/discharge air sensor to control the open or closed position of
both the outdoor and return dampers
The enthalpy sensor(s) used with an economizer control
changeover from free cooling to mechanical cooling
When troubleshooting a problem suspected to be caused by a malfunctioning economizer damper, one of the first things to do is
check an operating damper for defects and binding
Signs of high relative humidity include
condensation on windows
Defrost is initiated by the
defrost control
A two-pipe system in which supply and return water flow in opposite directions is called a
direct-return system
When a humidifier experiences water overflow, the problem is often caused by a
dirty float valve
A three way zone valve located at the inlet of a heating terminal acts as a
diverting valve
During dual-fuel heart pump operation, the compressor and furnace burner can operate together
during periods of defrost
In an economizer that uses differential enthalpy sensing, what type of air does the economizer control module select for cooling
either outside or return
In the cooling mode, the reversing valve is normally
energized
Air-to-air heat pumps produce heat by
extracting heat from the outdoor air and transferring it to the indoor air
If a humidifier is not running, the problem is usually caused by a
faulty control circuit
A boiler installed in a rural area is most likely to be fueled by
fuel oil
In addition to the reversing valve, the other major difference between a heat pump and a cooling-only system is that
heat pumps require two metering devices
The function of a reversing valve will be affected by all of the following EXCEPT
high superheat settings
Some humidifiers are controlled by
humidistat
A Belimo Pressure Independent Characterized Control Valve is a practical choice
in commercial hydronic systems with variable-speed pumps
When a heat pump is operating in the heating mode, the refrigerant bypasses the
indoor coil metering device
Pressure drop in a hydronic heating system is caused by
internal friction
The purpose of shutoff valves installed on both sides of a circulator pump is to
isolate the pump for repairs
If the outdoor thermostat is not closed and this system is in the heating mode, a likely symptom would be
less supplemental heat available
Water at different temperatures within a hydrating system will
migrate
A tight building is characterized by the
presence of tight windows
Differential-pressure gauges are commonly referred as
readout meters
A device that uses a heat exchanger to transfer heat from warmed indoor air to ventilation air entering a building is a
recovery ventilator
Low primary voltage at the control circuit transformer may cause
relay chatter
The heat pump component that is controlled through room thermostat terminal O is the
reversing valve
If a heat pump will not initiate defrost and you suspect the reversing valve, the quickest way to verify your suspicion is to
see if the reversing valve switches when the operating mode is changed
A one-pipe system has a continuous run of pipe from the supply connection to the return connection is called a
series-loop system
The first thing that must be determined before selecting a circulating pump is the
system flow rate in gpm
If a heat pump blows cool air into the conditioned space during the colder parts of the heating season, a possible cause is
that the supplemental electric heaters are not on during defrost
Which of the following actions is most likely to occur first when a zone thermostat calls for heat
the circulator pump starts
Which of the following conditions is not common and proper during the defrost mode?
the compressor shuts off
In the reverse-cycle heating mode
the indoor coil acts as a condenser
What happens in the cooling mode if the discharge temperature switch fails?
the outdoor fan does not run
Which of the following is true of a pilot-operated valve?
the solenoid coil operates a plunger which opens a smaller valve port
Energy recover ventilators are more likely to be found
throughout the united states
A slow-opening zone control valve helps prevent
water hammer
One possible cause of a low humidity complaint would be
water supply feed valve closed
When an electronic air cleaner is operated at an airflow above that recommended by the manufacturer, the filter's cleaning ability is
worse