HW TEST #2

Ace your homework & exams now with Quizwiz!

How many receptacles are required within the perimeter of a balcony, deck or porch with a usable area of less than 20 SQ. feet.

1

A 125-volt, single-phase, 15- or 20- ampere-rated receptacle outlet shall be installed at an accessible location for the servicing of heating, air conditioning, and refrigeration equipment. The receptacle shall be located on the same level and within of the heating, air-conditioning, and refrigeration equipment. The receptacle outlet shall not be connected to the load side of the equipment disconnecting means.

25FT

The maximum total voltage drop on branch-circuit conductors is _________ percent.

3

Receptacle outlets installed for a specific appliance in a dwelling unit, such as a laundry equipment, shall be located within ______________ of the intended location of the appliance

6 feet

As per New York City NEC in addition to the number of branch circuits required in a dwelling unit an individual branch circuit shall be provided for each ______.

Air Conditioner

There shall be a minimum of one ______________ branch circuit for laundry outlets required by 210.52.

b. 20A

Dwelling units circuits running through another dwelling unit in common areas. What percentage of change, will require it to be brought up to current code.

. 50%

Two or more small-appliance branch circuits shall be provided to supply power for receptacle outlets in the dwelling unit kitchen, dining room, breakfast room, pantry, or similar dining areas

15A

At least one receptacle outlet shall be installed within linear feet measured of the top of a show window for each 12 linear feet measured horizontally across its length.

18

Receptacle outlets in floors shall not be counted as part of the required number of receptacle outlets unless located within ___________ of the wall.

18"

Outlets may be installed in a dwelling unit for specific appliance such as laundry equipment. What is the maximum distance allowed between this outlet and the appliance?

6 ft

A receptacle connected to one of the dwelling unit small appliance branch circuits can be used to supply an ________________ in any of the rooms specified in 210.52(B)(1)

Electric Clock

The number of receptacle outlets for guest rooms in hotels and motels shall not be less than that required for a dwelling unit. These receptacles can be located to be convenient for permanent furniture layout but at least _____________ receptacle outlets shall be readily accessible.

two


Related study sets

1. Define and Establish a Community

View Set

Ch. 36: Pain Management in Children

View Set

AP Macro: Edge Ex: Economic Growth

View Set

Louisiana Life and Health Insurance Licensing: Chapter Two, Life Insurance Basics

View Set

Chapter 34: Caring for the Special Needs Child

View Set