Iahcsmm Exam Review #3

Ace your homework & exams now with Quizwiz!

85. The OSHA PEL for Hydrogen peroxide is ____ ppm: - 5 - 10 - 1 - 15

1

101. The minimum required SAL for sterilant is: - 10-6 - -60 - 110-6 - -106

10 -6

71. Sterile items should be stored following these measurements except: - 2" away from exterior walls - 8-10" above the floor - 12- 15" from the ceiling - all the above

12"- 15" from the ceiling

56. Muslin is a broad term for plain-weave cotton having approximately ______ threads per square inch: - 80 - 140 - 100 - 40

140

129. When examing through the lens of the rigid or semi-rigid endoscopes with the paper, this paper should be held approximately ______ inches from the distal tip. - 2 - 3 - 5 - 6

3

115. The standard temperature where EtO turns to gas is ______ degrees F. - 53.1 - 51.3 - 35.1 - 55.3

51.3

66. Proper coil size for sterilizing air hoses should be _____ to _____ inches: - 5-6 - 8- 10 - 9-12 - none of the above

9- 12

77. Tests for sterilization that uses bacteria spores: - BI - CI - Ampulization Test - Print outs

BI

133. Used to harvest skin grafts and reshape skin surfaces: - gastroscope - colonoscope - micro drill - dental drill - dermatome/ dermabraider -cebatome -sternal saw

Dermatome/Dermabraider

137. Which of the following has been the primary sterilant of choice for items that cannot withstand steam since the 1960's . - plasma - ozone - autoclave - EtO

EtO

133. Used to visualize the entire large intestine: - gastroscope - colonoscope - micro drill - dental drill - dermatome/ dermabraider -cebatome -sternal saw

colonscope

157. Placing warm steriliex package on a cool surface will cause: - condensate to form - dry steam of teh sterilization process

condensate to form

72. Factors that can cause strilant contact failure with the instrument are: - cleaning, loosely packed load - conditioning, size and weight of the instrument - solid buttom containers, exposure time - crowded loads, clogged drain strainer

crowded loads, clogged drain strainer

119. Equipment shortages can be caused if CS technicians fail to perform soiled pickup rounds: - true - false

false

121. The three power sources of PSIs are steam, electric, and pneumatic: - true - false

false

125. Facing paper to paper is the recommended arrangement for peel pouches in the sterilizer: - true - false

false

151. Patient census information used in Central Service is obtained from the electronic health record: - true - false

false

36. All sonic cleaners have a decontamination cycle? - true -false

false

44. Hydrogen peroxide gas plasma is compatible with powders and paper: - true - false

false

45. At least, 20 minutes is the time recommended for hand washing. - true - false

false

50. Computer supply chain management systems are used to monitor facility assets: - true - false

false

52. Computerized tracking systems are fast but manual tracking systems are more effective for tracking: - true - false

false

63. Endoscope channel should be cleaned and then left moist for storage. - true - false

false

69. Canvas has been approved by FDA as one of the best sterilization packing materials: - true - false

false

75. Flexible endoscopes that fail a leak test may be used until the break impacts the scope's function. - true - false

false

76. Gauze squares are the wicking material of choice for instrument sets: - true - false

false

79. Cleaning brushes clean better when they are larger than the lumens: - true - false

false

80. Textile packaging requires less labor than disposble packing: - true - false

false

84. Communication skills involve only verbal and written? - true - false

false

86. Connective tissue of the body includes the skin: - true - false

false

92. Immediate use steam sterilization (IUSS) is the process to sterilize trays for future use. - true - false

false

97. Decentralization of Central Service in now a growing trend: - true - false

false

112. The product rotation used in the storage area of sterile processing is: - first out last in - last in first out - first in first out - none of the above

first in first out

47. Coaching is an example of: - formal communication - informal communication - discipline - mentoring

formal communication

78. Cholecystectomy is the removal of the: - urinary bladder - small bowel - gall bladder - stomach

gall bladder

114. During pasteurization ______ is used: - phenols - high level disinfectant - heated water - sterilization

heated water

57. Below refers to an anatomy or level that is termed: - hyper - iso - para - hypo

hypo

88. Contaiminated items are normally returned to the decontamination area: - in open cart - in a closed cart - with clean items only - with sterile items

in a closed cart

58. Electronic testing of laparoscopic insulation should be done: - in the decontamination area prior to cleaning - in the clean assembly area prior to set assebly - at the factory or on site repair unit - in the Operating room at the end of the procedure

in the clean assembly area prior to set assembly

46. Hydrogen peroxide is a popular low temperature sterilizatio method because of: - its long cycle times - its abundant residue - its short sterilization cycle -its high toxicity

its short sterilization cycle

135. For a Central Service technician to understanding what is asked when a request is made for a surgical procedure requires: - medical terminology - high level english vocabulary - clinical experience - managerial skills

medical terminology

133. Used in ear surgery and for driving very small wires through bone: - gastroscope - colonoscope - micro drill - dental drill - dermatome/ dermabraider -cebatome -sternal saw

micro drill

30. Ethylene oxide is: - less toxic than ozone - more toxic than hydrogen peroxide gas plasma - just as toxic as steam - safer to use than gas plasma

more toxic than hydropgen peroxide gas plasma

89. Immediate Use Steam Sterilization documentation should include: - the name of the patient for which the items were sterilized - sterilizer number and cycle - name of the instrument sterilized - all of the above

name of the patient for which the items were sterilized, sterilizer number and cycle, name of the instrument sterilized

110. Due to event related sterility stock rotation is ____ for effective inventory: - not necessary - necessary

necessary

105. Detergents for cleaning most surgical instruments are: - acidic - base - alkaline - neutral

neutral

93. Craniotomy is: - fixing of facial fractures - incision into the scalp - open reduction of the skull - open made into the skull

opeing made into the skull

113. Items to be disinfected or sterilized at the point of use must be: - properly cleaned per Manufacturer's Instructions for Use - semi-critical devices - non-critical devices - heat sensitive

properly cleaned per Manufacturer's Instructions for Use

55. Count sheets: - describe each instruments in detail - are used only for Operating Room trays and large procedures packs - provide a detailed list of tray contents - include manufacturer's Instructions for use

provide a detailed list of tray contents

61. Binary Fission is a method of: - sterilization - reproduction - ATP production - colonization

reproduction

91. The amount of EtO that remains inside a material after they are sterilized is the: - aeration - the toxicity level - the residue - unapplied sterilant

residue

111. The process of monitoring requires the "4 R's". What is the meaning of the "4 R's": - remember, retain, remind, respond - retain, remind, read, record - run, read, remember, record - run, read, recod, retain

run, read, record, retain

133. Used to perform specific cutting actions such as reciprocating or oscillating: - gastroscope - colonoscope - micro drill - dental drill - dermatome/ dermabraider -cebatome -sternal saw

saw

107. Dressing forceps have: - teeth - serrations - both serrations and teeth

serrations

59. Beneath the skin is termed: - hypoglycemia - asepsis - subcutaneous - hypoxia

subcutaneaous

53. Bacteria that develops into spores: - survive in adverse conditions - are similar to viruses - are gram positive - are very susceptible to high level disinfection

survive in adverse conditions

145. One of the most frequent causes of a clogged drain screen is: - tape - wrapper particles - poor steam - malfunctioning baffle plate

tape

109. Information regarding cleaning processes for endoscopes should be provided by: - the Society of Gastroenterology Nurses and Associates - the Association for Professionals in Infection Control and Epidemiology - the Instrument manufacturer - the Operating Room staff

the instrument manufacturer

62. No toxic sterilant residuals should be left on packaging devices after sterilization process is completed. - to increase - to reduce the sterilization time - to avoid safety risks to patients - to prevent bacterial kill

to avoid safety risks to patients

100. Demineralized (treated) water should be used to thoroughly rinse all traces of disinfectant from an endoscope: - true - false

true

102. Inadequate exposure time at the correct elevated temperature is a reason for sterilization failure? - true -false

true

103. Information Technology is often the cornerstome of initative to transform healthcare: - true - false

true

108. Information about chemical or hazardous substances must be available to all employees: - true - false

true

123. Everyone entering the CS Department has to comply with department dress code: - true - false

true

149. Packs that are improperly packaged or loaded on the sterilizer cart frequently become wet packs: - true - false

true

155. High level disfection done at the point of use requires logging: - true - false

true

27. All mechanical cleaning equipment provides consistent process: - true - false

true

33. All rigid sterilization containers have tamper-evident seals: - true - false

true

42. Hydrogen peroxide allows faster instrument turnaround time than EtO: - true - false

true

48. Bacteriz are larger than viruses: - true - false

true

54. Low temperature sterilization requires physical, chemical, and biological monitoring: - true - false

true

60. Nitrogen can be used for pneumatic power: - true - false

true

68. Relative humidity is a required cycle parameter for ozone and ethlene oxide: - true - false

true

87. Immediate Use Steam Sterilization (IUSS) should be used only when there is no time to process items using the wrapped method: - true - false

true

98. In addition to providing financial and operational management, information technology and systems are used to help ensure patient safety: - true - false

true

141. Gold handle instruments are called: - microgrind - supercut - serrated - tungsten carbide

tungsten carbide

117. Endometrium is the lining of the: - heart - lungs - uterus - fallopian tubes

uterus

127. Floors in central service must be _____ daily: - swept - wet-mopped - vacummed - washed

wet-mopped

147. The meaning of SAL is: - Safety Assurance Level - Sterility Assurance Limit - Sterilant Aeration Limit - Sterility Assurance Level

Sterility Assurance Level

74. Sterilization packaging is classified by the FDA as a ____ packaging. - Class 2 - Class 4 - Class 3 - Class 1

Class 2

131. When packaging instruments only materials approved by ______ are used. - FDA - OSHA - AAMI - Joint Commission

FDA

73. Chemical Indicators are class 2 devices and regulated by: - AAMI - CDC - AORN - FDA

FDA

132. Fluid Resistant gowns used in the decontamination area to protect technicians from splashes and spills are enforced by: - AAMI - AORN - EPA - OSHA

OSHA

81. Healthcare facilities are required by the ____ to provide adequate ventilation systems, personal protective equipemnt and safe work operating procedures. - EPA - FDA - OSHA - Centers for Medicare and Medicaid Services

OSHA

106. The probability of a viable microorganism being present on a product unit after sterilization is known as: - PEL - SAL - TWA - IDLH

SAL

94. Implantable devices: - should be sterilized in immediate use steam sterilization in extended cycles - should only be sterilized using ethylene oxide -require double cycle sterilization to ensure sterility - should not be sterilized by IUSS unless there is a tracking system in place to track the item to a patient

Should not be sterilized by IUSS unless there is a tracking system in place to trace the item to a patient

51. Information about a device's compatibility witha specific sterilization process should be obtained from: - OSHA handbook - AAMI Regulations - Hospital Policy Manual - The manufacturer

The manufacturer

83. The 8 hour TWA is the: - permissible exposure limits for 40 hours work week - 15 minutes short- term excursion - total allowable worker exposure during an 8-hour period - standard action level for 8 hours

Total allowable worker exposure during an 8-hour period

64. Endoscopes are often processed in a mechanical unit called: - an ultrasonic cleaner - a washer decontaminator - a flush pulse endoscope reprocessor - an automatic endoscope reprocessor

an automatic endoscope reprocessor

67. Ergonomic injuries: - are not a concern for Central Service employees - are rare in today's work environment - are a risk factor for persons who perform repetitive or physical work - happen only in the office setting

are a risk factor for persons who perform repetitive or physical work

96. The consequences of a non-sterile item being used during surgery: - is safe for the patient - can be life threatening - is life saving - must be approved by the director

can be life threatening

99. The microorganism of choice to test items sterilized by EtO method is: - tubercle bacillus - geobacillus stearothermophilus - bacillus atrophaeus - mycobacterium tuberculosis

bacillus astrophaeus

70. Cell is the: - atomic number of living room - a combination of molecules - DNA of a nucleus - basic unit of a living organism

basic unit of a living organism

104. The most accepted means for providing quality assurance for H202 sterilizers is: - biological indicator - chemical indicator - physical monitoring - tape indicators

biological indicator

82. How frequently should a sterilizer's strainer be removed and cleaned? - daily - after each use - once weekly - only when the machine's operating control guage indicates cleaning is necessary

daily

95. Damaged light fibers of an endoscope shows ____ areas: - white -green - silver -dark

dark

90. The _______ process is the most critical step in processing loaner instrumentation: - receiving - documentation - decontamination - shipping

decontamination

133. Used to repair and reconstruct teeth: - gastroscope - colonoscope - micro drill - dental drill - dermatome/ dermabraider -cebatome -sternal saw

dental drill

49. Bacteria require _____ to live and grow: - the same conditions - only warm temperatures - different conditions - over 1000 degrees F

different conditions

43. Central Service technicians who do not think they are being treated appropriately by their employer should: - find another job - discuss the problem with their co-workers - discuss the situation with their supervisor - accept the situation as the way things are done in the facility

discuss the situation with their supervisor


Related study sets

TEST 7: Chapter 47 Mastering (Fundamentals of Nursing)

View Set

Anthropology of Sacred and Spiritual Exam 2

View Set

A Man For All Seasons Quotes and Review

View Set

Med- Surg II ATI Gastrointestinal

View Set

chapter 15 digestive system and nutrition chapter assessment

View Set

Wk 2 Main turbine and auxiliaries

View Set

Quiz #2 Chapter Review Questions

View Set