Michigan Mechanic Certification- HVAC

Ace your homework & exams now with Quizwiz!

Symptoms of a failing ambient temperature switch

A bad temperature switch could cause an inoperative clutch or input problems

Typical cause of a clogged orfice tube

A clogged orifice tube is typically caused by compressor failure

Low side pressure is high and high side pressure is low

An internally faulted compressor or a stuck open expansion valve

Symptoms of an overcharged system

Both the low and high side pressures will read higher than normal

What are CFCs

CFCs are a compound that destroys the ozone layer when released into the air

How is compressor clutch cycling operated

Cycling is accomplished through the engaging and disengaging of an electromagnetic clutch which is actuated by a module, relay and or switch

Symptoms of low coolant

Engine overheating and no heat from the HVAC system

Symptoms of a clogged orifice tube

Frost forming around the restricted area

Orifice expansion tube operation

Has a valve that can vary the size of the opening to allow more or less liquid refrigerant through to the evaporator

Orifice expansion tube purpose

High pressure liquid enters, low pressure liquid leaves

Purpose of a fixed orifice tube

High pressure liquid enters, low pressure liquid leaves

What is operating pressure of high side pressure?

High pressure should be between 170psi-230psi

Compressor clutch cycling operation

If the pressure becomes too high, the compressor clutch is cycled off, and if the pressure is too low, the compressor clutch is cycled on.

Reciever drier location

Located on the high side of the system between the condenser and the evaporator

Cause of low heater output

Low coolant level, clogged heater core, leaking heater core

Purpose of a compressor

Low pressure gas enters and high pressure gas leaves

Purpose of a condenser

Low pressure gas enters and high pressure gas leaves

Purpose of a evaporator

Low pressure liquid changes into low pressure gas

What is operating pressure of low side pressure?

Low pressure should be between 20psi-40psi

Reciever drier purpose

May contain a filter or strainer to catch and trap foreign particles and dirt

Effect of moisture in the system

Moisture in the a/c system will turn to acid and destroy all the components in the system

Ambient temperature switch purpose

Monitors temperature by increasing or decreasing with resistance as temperature changes

Both low side and high side pressures are high

Overcharge, faulty restriction device or blockage of the high side

Cooling system leak diagnosis

Pressure test or dye test

Symptoms of a failing compressor

Pressures are going to be equal

R-12 background

R-12 is Freon and it destroys the ozone layer due process of releasing CFCS into the air

What replaced R-12

R-134a

What causes CFCs

R12

What replaced R134a

R1234yf

Low side pressure is low and high side pressure is high

Restriction in a line or a stuck closed expansion valve

Symptoms of a failing evaporator

Symptoms of a failed component could be a leak, sniffer test required

Symptoms of a failing condenser

Symptoms of failure or restriction are a high high-side discharge of pressures

Effect of outside temperature & humidity on a system

Temperature and pressure are directly related. The higher the ambient temp, the higher your AC pressures will be. Higher pressure's will lead to a higher outlet vent temperature. Essentially, the air conditioning system does not work as well under extreme heat and humid conditions

Heater core operation

The blower motor blows air through the heater core fins and is warmed through the principle of conduction

How will the compressor act on an overcharged system

The compressor will run for a few seconds then turn off for long periods of time

Purpose of a radiator

The purpose of the radiator is to dissipate heat that is picked up by coolant in the engine into the air passing through its fins and tubes

Purpose of the thermostat

The purpose of the thermostat is to trap the coolant in the engine until it reaches it operating temperature

Heater core hose routing

The supply hose from the heater core should run from the closed side of the thermostat to the heater core and the return hose should run from the heater core to the engine

Heater control valve purpose

This valve controls the flow of the coolant to the heater core to control the temperature of the air desired by the operator

Radiator cap testing

To test pressure test it using an adapter and a coolant pressure tester and the value marked on the pressure cap

Causes of both low side and high side pressures are low

Undercharge or restriction at either the orifice tube or expansion valve

Compressor clutch cycling testing

power and ground should be sufficient and the clutch should only have 3-5 ohms of resistance


Related study sets

SST: Europeans Reach the Americas

View Set

WGU D053-Contemporary Topics and the Influence on Healthcare Today

View Set

8.3.10 Wireless Defenses Section Quiz

View Set

Chapter 19: Nursing Management of Pregnancy at Risk: Pregnancy-Related Complications

View Set

InterComm Ch. 9-12 - Quiz Questions & Material

View Set

PSYCH- issues and debates, free will vs determinism & nature vs nurture

View Set